• 제목/요약/키워드: large electric field

검색결과 376건 처리시간 0.026초

B-Spline곡선을 이용한 지정된 전계조건하의 전극형상 설계 (Design of Electrode Shape with B-Spline Curve Under Specified Field Condition)

  • 김응식;박종근
    • 대한전기학회논문지
    • /
    • 제39권9호
    • /
    • pp.964-975
    • /
    • 1990
  • This paper aims at the design of high voltage electrode contour under specified field condition. Defining the contour with B-Spline curve, the number of contour variables can be reduced and very smooth electrode can be obtained. For the analysis of the electric field, Surface Charge Method which has advantages in practical model has been used. As an initial contour, the rod-plane gap has been used since the difference between maximum and minimum field value is relatively large. Various field conditions including uniform field condition are given to the end of the rod electrode. Under uniform field condition, authors designed an electrode whose field-deviation was under 0.5%. Finally, the relation between the curvature and field of the electrode has been checked, which showed that B-Spline curve is appropriate for the shape function.

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Electro-osmosis에 의한 Dehydration (Dehydration by Electro-osmosis on Ceramic Body)

  • 한상목
    • 산업기술연구
    • /
    • 제4권
    • /
    • pp.43-46
    • /
    • 1984
  • In process of water removing safely from plastic clay, an electric field applied to a wet, porous solid such as day usually causes the rapid dehydration. The water-bearing positive ions move to negative electrode under the d. c. electrical stress or field. Therefore application of electro-osmosis to wet clay could include drying thick and large-scale ceramic body quickly and evenly. The d. c. power supply unit to 60 volts is necessary for safe practice. Also wider contact area and shorter distance between electrodes accelerate effectively the removal of water.

  • PDF

발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석 (Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator)

  • 성민영;김두현;김승태
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

Comparative Study of Conventional and Microwave Sintering of Large Strain Bi-Based Perovskite Ceramics

  • Kang, Jin-Kyu;Dinh, Thi Hinh;Lee, Chang-Heon;Han, Hyoung-Su;Lee, Jae-Shin;Tran, Vu Diem Ngoc
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2017
  • A comparative study of microwave and conventional sintering of lead-free $Bi_{1/2}(Na_{0.82}K_{0.18})_{1/2}TiO_3-BaZrO_3-CuO$ ceramics is presented. It was found that microwave sintering (MWS) can be successfully applied to the fabrication of large strain Bi-perovskite with electric field-induced strains comparable to those obtained with conventional sintering (CFS). Although MWS resulted in smaller grained microstructures than CFS, the ferroelectric properties were stronger in MWS-derived specimens than in the CFS-derived ones. The piezoelectric strain constant $d_{33}{^*}$ of the CFS-derived specimens reached a maximum value of 372 pm/V after sintering at $1100^{\circ}C$, whereas that of MWS-derived specimens peaked at $950^{\circ}C$ with a $d_{33}{^*}$ value of 324 pm/V.

전계방출광원용 카본나노파이버 에미터 연구 (Study on Carbon Nano Fiber Emitter for Field Emission Lamp)

  • 김광복;이선희;유승호;김대준;김용원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • Properties of carbon nano fiber (CNF) as field emitters were described. Carbon nano fiber (CNF) of herringbone was prepared by thermal chemical vapor deposition(CVD). Field emitters mixed with organic binders, conductive materials and were prepared by screen-printing process. In order to increase field emissions, the surface treatment of rubbing & peel-off was applied to the printed CNF emitters on cathode electrode. The measurements of field emission properties were carried out by using a diode structure inline vacuum chamber. CNF of herringbone type showed good emission properties that a turn on field was as low as 2.1 $V/{\mu}m$ and current density was as large as 0.15 $mA/cm^2$ of 4.2 $V/{\mu}m$ with electric field. Through the results. we propose that CNFs are suitable for application of electron emitters in Field Emission Devices.

  • PDF

Enhanced flexoelectric switching made from self-assembly of smectic liquid crystal and triallyl dopant

  • Lim, Tong-Kun;Lee, Ji-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.175-177
    • /
    • 2006
  • Here we report an enhanced flexoelectric switching in a self-assembled system of smectic liquid crystal and some specific dopant. The assembled unit block seemed to have electric dipole and as a result induces large flexoelectric polarization due to its asymmetric shape and shows fast switching to the electric field. The unit blocks are oriented in a helical fashion in the cell with large gap (${\sim}5{\mu}m$) and shows selective reflection property. In the thin cell (${\sim}2{\mu}m$), the unit blocks are aligned homeotropically on the bare ITO substrate with no surface treatment and shows fast decaying time.

  • PDF

최대경사 적분법을 이용한 지면위 큰 대형 표적의 산란 특성 (Scattering of arbitrarily large targets above a ground using steepest descent path integration)

  • 이승학;김채영;이창원
    • 대한전자공학회논문지TC
    • /
    • 제39권7호
    • /
    • pp.38-45
    • /
    • 2002
  • 본 논문은 손실 매질 내에 매설된 선 전류 안테나에 의한 크기가 큰 완전도체 표적의 산란파를 해석하기 위한 전장적분식을 도출하였다. Sommerfeld 형태의 적분은 어떤 해석영역에 대하여 계산의 어려움과 제약들을 가지고 있으며, 많은 계산시간이 필요하다. 반면 최대 경사적분은 빠른 결과의 산출을 제공하였으며, 또한 그 계산 결과는 모든 해석 영역에 적용 가능하다. 임의의 완전도체 표적의 산란파는 최대경사적분법과 MOM 방법이 사용되었으며, 계산 결과는 가우시안 구적법과 GPOF 방법에 의해 비교되었다.

피뢰기 소자(ZnO)의 열화특성에 관한 연구 (The Study on the Aging Characteristics of the Arrester Block(ZnO))

  • 김찬영;송일근;김주용;정년호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1459-1461
    • /
    • 1998
  • This paper provides the results of analysis of lightening arrester failed in the field. XRD was used for qualitative analysis and SEM for microstructure analysis of zinc oxide (ZnO) block. The failure of lightening arrester might occur due to the following reasons: the uneven size of zinc oxide grains and cement layers. the re-crystallization of zinc oxide grains resulting from electrical stress around impurities, and the presence of too large pores($\simeq$ 50 ${\mu}m$).

  • PDF

3전극 트리거 갭 스위치 동작특성에 관한 연구 (A Study on Operation Characteristics of Three Electrode Trigger Gap Switch)

  • 홍태윤;한상보
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.