• Title/Summary/Keyword: landfill

Search Result 1,302, Processing Time 0.026 seconds

Rehabilitation Method and Case of Closed Waste Landfill (사용종료매립지 정비방법 및 정비사례 분석)

  • 정하익
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.11a
    • /
    • pp.85-95
    • /
    • 2001
  • There has been a steady increase in closed waste landfill. Sanitary and contamination prevention systems such as liner system, leachate treatment, gas treatment system were not installed in unregulated waste landfill. This study was carried out to introduce the rehabilitation method and case of unregulated closed landfill.

  • PDF

Measurement of VOC in the Ambient Air of a Small Scale Municipal Landfill Site -A Case Study at the Sampung-dong Landfill in Gyungsan City- (소규모 도시 생활폐기물 매립장 대기 중 VOC의 농도 측정 -경산시 삼풍동 매립장을 대상으로-)

  • 백성옥;김배갑;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.59-68
    • /
    • 2004
  • In this study, we investigated the concentrations of volatile organic compounds (VOC) in the ambient air of a small scale municipal waste landfill site. Seasonal sampling was carried out simultaneously at two sites, i.e. one in the center of the landfill area, and the other at a boundary site. Among 38 target VOC, toluene appeared to be the most dominant compound, followed by benzene. and xylenes. The higher levels of BTX imply that paint -containing materials and/or organic solvents are the most significant sources of the VOC in the landfill environment. Seasonal variations for the samples collected at the landfill site indicated that the VOC concentrations tend to be higher in the spring and fall season and lower in the winter season. In addition, night- time concentrations appeared to be generally higher than day-time. Such daily variation might be due to more stabilized atmosphere during the night-time. Similar patterns were also found in samples collected at a boundary site. This study demonstrated that the municipal landfill, although it is small -scaled, could be an important emission source of atmospheric VOC, particularly in the vicinities of the landfill. Thus, an appropriate control strategy is required to prevent any undesirable secondary pollutions from the environmental sanitary facilities such as landfill.

Analysis of collection Characteristics of Landfill Gas Using ]Relative Fluid Permeability of Gas and Water in Waste Landfill (쓰레기 매립지에서 가스-물 상대유체투과도를 적용한 매립가스의 포집특성분석)

  • 김인기;허대기;김현태;김세준;성원모
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.35-54
    • /
    • 2001
  • It is difficult to accurately predict each flow rate of landfill gas and leachate extracted from many of wells, which have been completed into a waste landfill containing gas and water. However it may be approximately predicted if we can define only relative fluid permeability of gas and leachate flowing through landfill porous media. Therefore numerical simulation using multi-phase flow equations makes use of ei s input data of the relative permeability which is measured and calculated in laboratory environment like in-situ, and consequently we can quantitatively obtain each flow rate of gas and leachate from collection wells. These series of technologies can provide with the important informations to determine the success or failure of landfill gas energy and landfill stabilization. This paper analyses the characteristics of landfill gas collection by six classes of case studies for none described landfill.

  • PDF

Analysis of Soil Contamination with Depth in Non-sanitary Closed Waste Landfill (비위생 사용종료매립장의 심도별 토양오염도 분석)

  • Oh, Young-In;Kim, Kwan-Ho;Lee, Dong-Geon;Cho, Sook-Hee;Bak, Eun-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1217-1224
    • /
    • 2010
  • These days, the maintenance of closed waste landfill come to the fore social problem such as legal maintenance period, after closed maintenance deposits, stability evaluation guides and environmental survey for closed landfill management. Therefore the many non-sanitary closed waste landfill has been removed by selection and transfer to sanitary landfill and incineration. When the remove the non-sanitary landfill, the pollution level of bottom soil was investigated by related government law. In this case study, the soil contamination survey was performed to evaluate the pollution level of non-sanitary closed landfill bottom soil. Based on this study, the pollution level of studied non-sanitary landfill bottom soil was content with related government law for third area(factory, parking lot, gas station, road, railroad use etc.).

  • PDF

Long-term Settlement Characteristics of Closed Landfill (사용종료 쓰레기매립지의 장기침하특성 분석)

  • 정하익;진현식;김상근;이강민;김태섭
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.605-610
    • /
    • 2002
  • Waste body settlement is an important aspect of management of landfill sites both during the operational and the post-closure phases. Settlement in landfill waste is caused by combination of load, creep and biodegradation induced effects. In this paper, settlement characteristics of closed waste landfill were studied by analyzing in situ measured data and computer simulation technique. Techniques for the analysis of load-induced and creep settlement, and for their implementation, can be adapted for landfill waste. The estimate of settlements from models shows a increase according to time.

  • PDF

An Estimation Method of Organic Matter Content Ratio for the Termination of Post-closure Maintenance of a Landfill (매립장 사후관리종료를 위한 유기물 함량비 산정방법)

  • Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.4
    • /
    • pp.11-19
    • /
    • 2019
  • This paper examines an assessment method for terminating the post-closure maintenance of a landfill using a simplified landfill gas model. The case study site is the Sudokwon Landfill in Incheon city, which was closed in 2000. The deviations of the results obtained by the regular model and the simplified model were both slightly over 10% from the measured data. Also, the deviation of the simplified model from the regular model has been less than 5% since 2005. Thus, the simplified model could be applied to other landfills that have been closed for at least 5 years. Additionally, the results of the mass balance analysis using the simplified landfill gas model indicated that 39% of the organic carbon was discharged, leading to organic carbon and organic matter content of 7.2 and 17.6%, respectively, in the landfill by the end of 2018.

Analysis of the Relationship between the Seasonal Temperature Change and the Electrical Resistivity Value of Landfill Site (매립지의 계절별 온도변화와 전기비저항값의 상관성 분석)

  • Sim, Nak Jong;Ryu, Don Sik;Kim, Chang Gyun;Lee, Chul Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.534-541
    • /
    • 2017
  • The bioreactor type of landfill is to operate to enhance waste decomposition by continuously supplying water such as leachate and wastewater within the landfill, which helps increase the landfill gas production, which in turn prematurely stabilize the landfill. Recently, the environmental law for the operation of the bioreactor type of landfill has been enacted and thereafter the bioreactor type of landfill has been introduced for the first time in Korea to the SUDOKWON landfill site. In order to properly apply for bioreactor to the landfill, it is necessary to investigate the water distribution inside the landfill so that water recirculation should be optimally allocated with the zone of concern. In this regard, electrical resistivity survey has been suitably performed to delineate the water distribution in the landfill. That is, it has surveyed for long-term of period that the recirculation of leachate has been properly reflected from electrical resistivity within the second landfill of SUDOKWON landfill site. As a result, the electrical resistivity immediately corresponded to the variation of the extent of the seasonal temperature dynamics. From this, a calibratrion could be accomplished by correlating between temperature and electrical resistivity obtained from this study that can be applicable for optimally monitoring to keep the ideal operating condition for the bioreactor type of landfill.

A Study on Variation of Landfill Gases in Completed Refuse Landfill Site after the Stabilization (사용종료 매립지의 지반안정화 후 매립가스의 변화)

  • Lee, Min-Hee;Ju, So-Young;Park, Jun-Kyu;Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • The reclaimed waste layer in a completed refuse small landfill site was stabilized by JSP(Jumbo Special Pattern System) method. There were some variations of landfill gases(LFGs) after the stabilization. This study investigated the landfill gases emitted from a open dumping landfill site. We measured concentration of landfill gases before and after the construction, and 28 months later. As a result, the concentrations of $H_2S$ and $NH_3$ gases before the construction were 123.51ppm and 171.54ppm, respectively. These values were higher than TWA(Time Weighted Average) values. But the concentrations of $H_2S$ and $NH_3$ gases after the construction were 55.59ppm and 20.51ppm, and they also decreased 9.04ppm and 11.82ppm in 28 months. $CH_4$ and other landfill gases after the construction were little or a little detected in the landfill site. Hence we found out that concentrations or classes of landfill gases causing some problems extremely decreased by way of the stabilization.

  • PDF

Prediction of Malodorous Landfill Substances Effect on Ambient Air Quality - A Case Study on Cheongju·Cheongwon Metropolitan Landfill - (매립지 악취가 주변 대기질에 미치는 영향 예측 - 청주청원 광역매립지 사례연구 -)

  • Lee, Sang-Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.695-705
    • /
    • 2012
  • The purpose of this study is to investigate concentration level and characteristics of malodour substances generated from landfill site in C city. Also, it is tried to predict distribution of concentration level using ISCST3 model around landfill site. From the results, it can be confirmed that twelfth-class malodour substances such as ammonia, methyl mercaptan, hydrogen sulfide, dimethyl sulfate, dimethyl disulfate, toluene, acetaldehyde, styrene, propionaldehyde, butylaldehyde, n-Valeraldehyde, xylene were generated from landfill site. The levels of the malodour substances were lower than that of permeable concentration regulated by odor control law in Korea. However, the concentration of malodour substances including methyl mercaptan, hydrogen sulfide, acetaldehyde, and propionaldehyde exceeded threshold limit value(TLV). It was seemed that these substances caused the problem of offensive odor around circumstance of landfill. The concentration of malodour substances was higher in slant than in upper part of landfill. The concentrations of malodour substances measured at night time were shown higher level than those at night time because atmospheric condition was stable at night time. It showed that the concentration of malodour substances were higher in spring. The results of atmospheric diffusion model predicted that tolerance limit level of hydrogen sulfide and methyl mercaptan was detected within nearly 5km from the boundary of landfill.

Permeability Influence of Base Soil for Analysis of Road Landfill Stability (도로성토사면의 안정성 분석시 원지반 투수성의 영향)

  • Kim, Young-Muk;Kim, Chung-Ki;Kim, Man-Goo;Kim, Geon-Hae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.890-897
    • /
    • 2005
  • Stability of embankment is influenced on landfill condition, permeability, shear strength and soil engineering propensity and so on, and need examination in reply because is different according to change of soil property of foundation ground and permeability condition. Analyzed seepage behaviour by finite element method for embankment, and change permeability of base to analyze effect that permeability of ground water table formation before embankment and analyze seepage behaviour to typical embankment in this research. In the case of permeability of foundation ground is 10 more than landfill permeability, rise of groundwater table was changed slightly. Pore water pressure was decreased slowly in landfill after rainfall. The effect of permeability of foundation ground was effected in change of pore water pressure. For permeability of foundation ground is 10 more than landfill, stability of road landfill was small changed during rainfall. But in the case of permeability of base soil similar to landfill permeability, road landfill stability was large decreased during rainfall.

  • PDF