• 제목/요약/키워드: laboratory calibration

검색결과 394건 처리시간 0.025초

백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법 (Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors)

  • 감기술;유성호;김성민;이인식
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.

A Noise Re-radiation Calibration Technique in Interferometric Synthetic Aperture Radiometer for Sub-Y-type Array at Ka-Band

  • Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.577-580
    • /
    • 2004
  • To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise re­radiation effect are presented.

  • PDF

EXAMINING THE BOUNDARIES OF INSTRUMENT-TO-INSTRUMENT CALIBRATION TRANSPORT

  • Kester, Michael D.;Baudais, Fred L.;Simpson, Michael B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1191-1191
    • /
    • 2001
  • Generation of precise, accurate, and robust calibration models for spectroscopic methods of analysis can be time-consuming, expensive, and sometimes difficult to achieve. For these reasons, efforts have been made to find ways in which the calibration from one instrument can be moved to another with minimal performance reduction. A slight shift in nomenclature from the common term calibration transfer to the term calibration transport is used here to help resolve the subtle difference between two means of moving a calibration from one instrument to another. The former term denotes a transfer procedure that includes mathematical manipulation of the calibration data via some determined transfer function, whereas the latter term does not. Todays generation of process and laboratory FTNIR analyzers is capable of not only achieving calibration transfer, but also calibration transport often without the need of slope or bias adjustments. Several studies are used to examine the boundaries of the extent to which calibration transport is achieved in the refining industry. Data collected on multiple on-line and laboratory FTNIR analyzers located in multiple countries are considered, and the ultimate limitations discussed.

  • PDF

Adaptive Calibration Method in Multiport Amplifier for K-Band Payload Applications

  • Moon, Seong-Mo;Shin, Dong-Hwan;Lee, Hong-Yul;Uhm, Man-Seok;Yom, In-Bok;Lee, Moon-Que
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.718-721
    • /
    • 2013
  • This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port-to-port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed $2{\times}2$ and $4{\times}4$ MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.

Laboratory geometric calibration simulation analysis of push-broom satellite imaging sensor

  • Reza Sh., Hafshejani;Javad, Haghshenas
    • Advances in aircraft and spacecraft science
    • /
    • 제10권1호
    • /
    • pp.67-82
    • /
    • 2023
  • Linear array imaging sensors are widely used in remote sensing satellites. The final products of an imaging sensor can only be used when they are geometrically, radiometrically, and spectrally calibrated. Therefore, at the first stages of sensor design, a detailed calibration procedure must be carefully planned based on the accuracy requirements. In this paper, focusing on inherent optical distortion, a step-by-step procedure for laboratory geometric calibration of a typical push-broom satellite imaging sensor is simulated. The basis of this work is the simulation of a laboratory procedure in which a linear imager mounted on a rotary table captures images of a pin-hole pattern at different angles. By these images and their corresponding pinhole approximation, the correction function is extracted and applied to the raw images to give the corrected ones. The simulation results illustrate that using this approach, the nonlinear effects of distortion can be minimized and therefore the accuracy of the geometric position of this method on the image screen can be improved to better than the order of sub-pixel. On the other hand, the analyses can be used to proper laboratory facility selection based on the imaging sensor specifications and the accuracy.

KOLAS 교정기관 간 측정 동등성 확립을 위한 상대습도 변환기 숙련도 시험 (Relative Humidity Transducer Proficiency Test for KOLAS Humidity Calibration Laboratories)

  • 이상욱;이영석;최병일
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.447-454
    • /
    • 2023
  • The Korea Laboratory Accreditation Scheme (KOLAS) operates accreditation programs for ensuring measurement traceability with the International System (SI) of Units - the highest calibration standard that measurements can be tested against. As of September 2023, there are 70 KOLAS-accredited laboratories in the Republic of Korea that specialize in humidity calibration. Among them, 32 KOLAS laboratories, along with one laboratory not affiliated with KOLAS, participated in the proficiency test (PM 2023-11) for relative humidity transducers in 2023. This proficiency test was conducted within a relative humidity range of 20-90% at a temperature of approximately 20 ℃, taking into consideration the calibration and measurement capability (CMC) of the participating laboratories. The primary objective of the proficiency test was to establish the measurement equivalence between each participating laboratory and the reference laboratory, by calculating the number of equivalence (En). When |En| was less than 1, the measurements from the participating and reference laboratory were equivalent. Out of the 33 participating laboratories, 32 successfully met this criterion and passed the proficiency test.

30 MHz에서 1 GHz 대역 EMI 측정용 다이폴안테나 교정의 측정 불확도 (Measurement Uncertainty for Calibration of EMI Dipole Antenna from 30 MHz to 1 GHz)

  • 박정규;정동찬;조진영
    • 한국전자파학회논문지
    • /
    • 제18권2호
    • /
    • pp.166-176
    • /
    • 2007
  • 측정 분야나 교정 분야에서 측정 불확도를 보고하는 것은 매우 중요하다. 정보통신부 전파연구소에서는 EMI 측정 시험소를 위하여 안테나 교정 서비스를 제공하고 있는데, 안테나 교정의 정확성은 측정 불확도 평가로 집약되어, EMI 시험의 신뢰성을 판가름하는 시금석이 된다. EMI에 관한 국제기구인 CISPR에서는 2005년 말에 안테나 교정에 대한 최초의 표준 초안인 CISPR/A/644/C를 내놓았다. 이 초안은 안테나교정 및 관련된 측정 불확도를 포함하고 있다. 본 논문에서는 이 문서를 근간으로 전파연구소 이천의 안테나 교정시험장에서 EMI용 다이폴안테나를 교정할 때의 측정 불확도를 산출하였다. 전파연구소의 안테나 교정 방법은 자유 공간 안테나 인자를 측정하는 3-안테나의 height scanning averaging 법으로서, 본 방법에 의하여 안테나가 교정될 때 측정 결과에 영향을 미칠 수 있는 모든 불확도 요인을 고려하였다.

Piezoelectric 6-dimensional accelerometer cross coupling compensation algorithm based on two-stage calibration

  • Dengzhuo Zhang;Min Li;Tongbao Zhu;Lan Qin;Jingcheng Liu;Jun Liu
    • Smart Structures and Systems
    • /
    • 제32권2호
    • /
    • pp.101-109
    • /
    • 2023
  • In order to improve the measurement accuracy of the 6-dimensional accelerometer, the cross coupling compensation method of the accelerometer needs to be studied. In this paper, the non-linear error caused by cross coupling of piezoelectric six-dimensional accelerometer is compensated online. The cross coupling filter is obtained by analyzing the cross coupling principle of a piezoelectric six-dimensional accelerometer. Linear and non-linear fitting methods are designed. A two-level calibration hybrid compensation algorithm is proposed. An experimental prototype of a piezoelectric six-dimensional accelerometer is fabricated. Calibration and test experiments of accelerometer were carried out. The measured results show that the average non-linearity of the proposed algorithm is 2.2628% lower than that of the least square method, the solution time is 0.019382 seconds, and the proposed algorithm can realize the real-time measurement in six dimensions while improving the measurement accuracy. The proposed algorithm combines real-time and high precision. The research results provide theoretical and technical support for the calibration method and online compensation technology of the 6-dimensional accelerometer.

Advanced On-chip SOL Calibration Method for Unknown Fixture De-embedding

  • Yoon, Changwook;Chen, Bichen;Ye, Xiaoning;Fan, Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권4호
    • /
    • pp.543-551
    • /
    • 2017
  • SOL (Short, Open and Load) calibration based on iterative error sensitivity is proposed in this paper. With advanced SOL calibration, unknown parasitic parameters at on-chip terminations are accurately estimated up to 20 GHz. Artificial terminations are designed on printed circuit board (PCB) to experiment the proposed method. On-chip SHORT, OPEN and LOAD fabricated inside silicon shows the accuracy of proposed calibration method through the comparison with known fixture S-parameter after de-embedding.