• Title/Summary/Keyword: lR Curve

Search Result 329, Processing Time 0.029 seconds

Determination of Inorganic Mercury in Urine and Airborne by Cold Vapor Atomic Absorption Spectrophotometry (냉각증기 원자흡수분광법에 의한 뇨 및 공기중의 무기수은 정량에 관한 연구)

  • Oh, Doe Suk;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 1991
  • Inorganic mercury in urine and airborne was determined by cold vapor atomic absorption spectrophotometry. Detailed sampling methods and analylical results are as follows : 1. 100~200ml of urine for each person was taken in 250 ml borosilicate bottle and $K_2S_2O_8$ (0.1g/100ml urine) was added to prevent bacterial contamination. About 1001 air of workingplace was absorbed in l0ml of absorbing solution. Urine samples and absorbing solution tubes were stored at $4^{\circ}C$. Dillution solution to prepare standard solution used deionized water (D.W) for urine and absorbing solution (A.S) for air. 2. 1n this procedure deteclion limit was 1ng/ml and mercury contents of blank reagent solution was 1~2ng/ml. 3. Calibration range was $0.02{\sim}0.1{\mu}g/ml$ and in this range r.s.d for each calibration curve in D.W and A.S and ${\pm}7.9%$ and ${\pm}3.7%$, respectively. 4. Repeatability (n=5 times, conc. $0.05{\mu}g/ml$) was ${\pm}5.8%$, in D.W. and ${\pm}4.4%$ in A.S, respectively. 5. Recovery for urine adding spiked concentration ($0.05{\mu}g/ml$) was about 90%. 6. Analytical result of samples was $1{\sim}139{\mu}g/l$ in urine and ${\sim}0.127mg/m^3$ in airborne.

  • PDF

Quantitative Determination of the Marker Constituent of Dioscoreae Rhizoma by the Packaging Methods (포장방법에 따른 산약(山藥) 지표성분의 함량분석)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Kim, Ho-Kyoung;Seo, Young-Bae;Shin, Hyun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.45-49
    • /
    • 2008
  • Objectives: To investigate the quantitative determination of marker constituents of Dioscoreae Rhizoma by the packaging methods Methods: HPLC for the determinations of allatoin in the Dioscoreae Rhizoma. the separation method was performed on an Luna $NH_2$ column($250mm{\times}4.6mm,\;5{\mu}m$, Phenomenes) using solvent water-acetonitrile(2:8, v/v%) with photo diode array detector(210nm). The flow rate was 2.0 mL/min. Results: Retention time of allatoin in HPLC chromatogram was about 4.8 min and calibration curve showed good linearity($R^2$=0.9994) at concentrations from 50.0 to 1000.0 ${\mu}g/mL$ of allantoin. Average content of allantoin by packaging methods was $0.16{\sim}0.40%$. In addition. weight loss rate(%) of Dioscoreae Rhizoma according to the packaging methods was $-0.60{\sim}1.80%$. Conclusions: The variation on content of the marker constituent of Dioscoreae Rhizoma by the packaging methods didn't show difference.

  • PDF

Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Nicorandil in Human Plasma (Tandem Mass를 이용한 혈중 니코란딜의 정량법 개발 및 생체이용률시험)

  • Moon Chul-Jin;Lee Eun-Hee;Yang Song-Hyun;Moon Hae-Ran
    • YAKHAK HOEJI
    • /
    • v.49 no.3
    • /
    • pp.225-229
    • /
    • 2005
  • A rapid, sensitive and selective tandem mass spectrometric method (LC-MS/MS) for the quantitation of nicorandil in human plasma was developed. A bioavailability study of Sigmat tablet (5 mg nicorandil, Choongwae Co.) was per-formed using the validated LC-MS/MS method. The dose of 5 fig of nicorandil (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.25, 0.5, 1, 2, 3, 4, 5, 6, 9, 12, and 24 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $0.5\~200.0 ng/ml$. The coefficient of variation for intra- and inter-day assay were $3.55\~7.44$, and $2.17\~9.102\%$, respectively. The lower limit of quantification for nicorandil was 0.5 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 145.9$\pm$83.0 ng-hr/ml, Cmax was 83.8$\pm$32.2 ng/ml, $C_{max}$ was 0.42$\pm$0.13 hr, $K_e$ was 0.56$\pm$0.23 l/hr, and $t_{l/2}$ was 1.42$\pm$0.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of nicorandil dos-age forms was prepared successfully and could be used for the bioequivalence test of nicorandil preparation.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

HPLC/DAD Method Validation of 6-Hydroxyluteolin 7-O-Glucoside Analysis from Salvia plebeia (곰보배추에 함유된 6-Hydroxyluteolin 7-O-Glucoside 분석을 위한 HPLC/DAD 분석법 밸리데이션)

  • Lee, Hak-Dong;Paje, Leo Adrianne;Choi, Jungwon;Kim, Juree;Yu, A Ram;Bae, Min-Jung;Lee, Sanghyun
    • Korean Journal of Pharmacognosy
    • /
    • v.52 no.3
    • /
    • pp.186-191
    • /
    • 2021
  • We developed a method to identify and quantify 6-hydroxyluteolin 7-O-glucoside in the powder of Salvia plebeia (PS) using high-performance liquid chromatography coupled with diode array detector (HPLC/DAD) and equipped with reverse-phase INNO C18 column. The analytical method was optimized and validated using novel parameters. The obtained values for the limits of detection and quantification were 3.60 and 10.90 ㎍/mL, respectively. Calibration curve showed good linearity in the concentration range tested (0.00625-0.1 mg/mL, r2 = 1.0000), high accuracy (96.2-101.4%), and precision values (RSD ≤ 0.27%). Our analysis support the use of our method for accurately identifying and quantifying 6-hydroxyluteolin 7-O-glucoside from PS in routine analyses and large-scale extraction processes for content determination.

Quality and Thermoluminescence Properties of ${\gamma}$-Irradiated Boiled-Dried Anchovies during Storage (감마선 조사와 저장 기간에 따른 건멸치류의 품질 및 열발광 특성)

  • 권중호;노정은;변명우
    • Food Science and Preservation
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2002
  • The effect of gamma irradiation was investigated on the microbiological and physicochemical qualities of boiled-dried anchovies (large- and smallsized) packed in PVC film (0.06 ㎜) during storage at 15$\pm$1$\^{C}$ for 6 months. On the other hand, thermoluminescence characteristics of minerals extracted from the sample were analyzed to evaluate its possibility in detecting the irradiated anchovies. The samples were contaminated by microbial levels of 104∼106 CFU/g in total aerobic bacterial counts and negative in coliforms, which were different depending on the sample sizes. Gamma irradiation at 3 kGy was effective for improving the hygienic quality of both samples for 6 months, keeping the microbial population less than 20 CFU/g. Besides it was not detrimental to the quality attributes, such as instrumental color parameters L, a, b, ΔE), browning, TBA value, volatile basic nitrogen, trimethylamine-N and sensory properties(appearance, color, odor, tape, overall acceptability). However, storage conditions (time, temperature, packing) showed a critical factor nfluencing the quality changes of dried anchovies. Thermoluminscence analysis was prove to distinguish irradiated from non-irradiated anchovies by comparing both temperature at which glow curves appear and the curve intensity, that was possible even after 6 months at - 20$\^{C}$.

Greenhouse Environment and Growth of Green Pepper (Capsicum annuum L.) in Greenhouse Covered with CEM BIO Film (CEM BIO Film 피복시설의 환경특성과 풋고추 생육)

  • Chun, Hee;Kim, Kyung-Je;Kwon, Young-Sam;Kim, Hyun-Hwan;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.161-165
    • /
    • 2000
  • Spectroradiometric light transmittance from 300 to 1,100nm in the greenhouse covered with the CEM BIO polyethylene film was greater than that in the greenhouse covered with polyethylene film (control). As a whole, solar radiation transmittance into greenhouse was a half level, due to shades caused by double layer covering, frame and equipment. Net radiation energy emitted throughout surface of the greenhouse covered with CEM BIO polyethylene film was 5,424.5W.m$^{-2}$ , which was lower by 2.9% as compared to that of the greenhouse covered with polyethylene film. Photosynthetically active radiation from 400 to 700nm of the greenhouse covered with CEM BIO polyethylene film was 3,861.2W.m$^{-2}$ , which was higher by 3.8% as compared to hat of the greenhouse covered with polyethylene film. Accumulated minimum air temperature from Oct. 7, 1997 to Oct. 16, 1997 of the greenhouse covered with CEM BIO polyethylene film was 100.5$^{\circ}C$, which was higher by 2.5$^{\circ}C$ as compared to that of the greenhouse covered with polyethylene film. As results, height, stem diameter, leaf count, leaf area, fresh weight and dry weight of green pepper plants and canopy production structure measured at 30 days after transplanting were enhanced. Mean fruit weight n the greenhouse covered with CEM BIO polyethylene film was 11.28 g and 1.25 g greater as compared to that in the greenhouse covered with polyethylene film, due to increased fruit diameter and flesh thickness. Percent marketable fruits produced in the greenhouse covered with CEM BIO polyethylene film were 96.1%, and was greater by 2.7% thant that of the greenhouse covered with polyethylnee film due to decreased infection, sterility, severe curve and twisted fruits. The green pepper yield of the greenhouse covered with CEM BIO polyethylene film from Nov. 19, 1997 to Feb. 3, 1998 was greater by 974 kg per hectare than that of the greenhouse covered with polyethylene film, but the total fruit had no difference.

  • PDF

Diagnostic Value of Cyfra 21-1 in Differential Diagnosis of Pleural Effusion (흉수의 감별 전단으로 Cyfra 21-1의 진단적 가치)

  • Lee, Hak-Jun;Lee, Kwan-Ho;Shin, Kyeong-Cheol;Shin, Chang-Jin;Park, Hye-Jung;Mun, Yeung-Chul;Lee, Kyung-Hee;Chung, Jin-Hong;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.50-56
    • /
    • 1999
  • Background : Pleural effusion is a common clinical problem and many clinical and laboratory evaluations, such as tumor marks, have been studied to discriminate malignant pleural fluid from benign pleural fluid. However their usefulness in the diagnosis of pleural effusion is still not established fully. We studied the diagnostic value of cyfra 21-1 in diagnosis of malignant pleural effusion. Methods: Pleural fluid was obtained from 45 patients with malignant diseases(32 lung cancer patients, 13 metastatic malignant diseases) and 47 patients with benign diseases. The level of cyfra 21-1 in the pleural fluid and serum were determined using a CYFRA 21-1 enzyme immunoassay kit(Cis-Bio International Co.). The t-test was used for comparison between two diseases groups and receiver operating characteristic(ROC) curves were constructed by calculating the sensitivities and specificities of the cyfra 21-1 at several points to determine the diagnostic accuracy of the cyfra 21-1. Results: In patients with primary lung cancer, the level of cyfra 21-1 in the pleural fluid was significantly higher than those of patients with benign diseases and had positive correlations between the level of cyfra 21-1 in the pleural fluid and serum levels. In the ROC curve analysis of the pleural fluid, the curve for primary lung cancer group was located closer to the left upper comer and the cut off value, sensitivity and specificity of the cyfra 21-1 of the primary lung cancer group was determined as 22.25ng/ml, 81.8% and 78.7% respectively. Conclusions: Our data indicates that the measurement of cyfra 21-1 level in pleural effusion has useful diagnostic value to discriminate malignant pleural effusion in primary lung cancer from benign pleural effusion.

  • PDF

Evaluation of microplastic in the inflow of municipal wastewater treatment plant according to pretreatment methods (전처리 방법에 따른 하수처리장 유입수에서의 미세플라스틱 성상분석 평가)

  • Kim, Sungryul;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.83-92
    • /
    • 2022
  • The amount of the plastic waste has been increasing according to global demand for plastic. Microplastics are the most hazardous among all plastic pollutants due to their toxicity and unknown physicochemical properties. This study investigates the optimal methodology that can be applied to sewage samples for detecting microplastics before discussing reducing microplastics in MWTPs. In this study, the effect of different pretreatment methods while detecting microplastic analysis of MWTP influent samples was investigated; the samples were collected from the J sewage treatment plant. There are many pretreatment methods but two of them are widely used: Fenton digestion and hydrogen peroxide oxidation. Although there are many pretreatment methods that can be applied to investigate microplastics, the most widely used methods for sewage treatment plant samples are Fenton digestion and H2O2 oxidation. For each pretreatment method, there were factors that could cause an error in the measurement. To overcome this, in the case of the Fenton digestion pretreatment, it is recommended to proceed with the analysis by filtration instead of the density separation method. In the case of the H2O2 oxidation method, the process of washing with distilled water after the reaction is recommended. As a result of the analysis, the concentration of microplastics was measured to be 2.75ea/L for the sample using the H2O2 oxidation method and 3.2ea/L for the sample using the Fenton oxidation method, and most of them were present in the form of fibers. In addition, it is difficult to guarantee the reliability of measurement results from quantitative analysis performed via microscope with eyes. A calibration curve was created for prove the reliability. A total of three calibration curves were drawn, and as a result of analysis of the calibration curves, all R2 values were more than 0.9. This ensures high reliability for quantitative analysis. The qualitative analysis could determine the series of microplastics flowing into the MWTP, but could not confirm the chemical composition of each microplastic. This study can be used to confirm the chemical composition of microplastics introduced into MWTP in the future research.

Inspiratory Flow Rate for the Evaluation of Bronchodilator in Patients with COPD (만성폐쇄성폐질환 환자에서 기관지확장제 흡입에 대한 흡기환기지표의 반응)

  • Baik, Jae-Joong;Park, Keon-Uk;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.342-350
    • /
    • 1995
  • Background: Although there are improvements of clinical symtoms after bronchodilator inhalation in COPD patients, it has been noted that there was no increase of $FEV_1$ in some cases. $FEV_1$ did not reflect precisely the improvement of ventilatory mechanics after bronchodilator inhalation in these COPD patients. The main pathophysiology of COPD is obstruction of airway in expiratory phase but in result, the load of respiratory system is increased in inspiratory phase. Therefore the improvement of clinical symptoms after bronchodilator inhalation may be due to the decrease of inspiratory load. So we performed the study which investigated the effect of bronchodilator on inspiratory response of vetilatory mechanics in COPD patients. Methods: In 17 stable COPD patients, inspiratory and expiratory forced flow-volume curves were measured respectively before bronchodilator inhalation. 10mg of salbutamol solution was inhaled via jet nebulizer for 4 minutes. Forced expiratory and inspiratory flow-volume curves were measured again 15 minutes after bronchodilator inhalation. Results: $FEV_1$, FVC and $FEV_1$/FVC% were $0.92{\pm}0.34L$($38.3{\pm}14.9%$ predicted), $2.5{\pm}0.81L$($71.1{\pm}21.0%$ predicted) and $43.1{\pm}14.5%$ respectively before bronchodilator inhalation. The values of increase of $FEV_1$, FVC and PIF(Peak Inspiratory Flow) were $0.15{\pm}0.13L$(relative increase: 17.0%), $0.58{\pm}0.38\;L$(29.0%) and $1.0{\pm}0.56L$/sec(37.5%) respectively after bronchodilator inhalation. The increase of PIF was twice more than $FEV_1$ in average(p<0.001). The increase of PIF in these patients whose $FEV_1$ was not increased after bronchodilator inhalation were 35.0%, 44.0% and 55.5% respectively. Conclusion: The inspiratory parameter reflected improvement of ventilatory mechanics by inhaled bronchodilater better than expiratory parameters in COPD patients.

  • PDF