• Title/Summary/Keyword: k-out-of n systems

Search Result 346, Processing Time 0.027 seconds

Optimal Maintenance Scheduling in a Two Identical Component Parallel Redundant System Subject to Exponential Power Hazards

  • El-Damcese, M.A.;Helmy, A.N.
    • International Journal of Reliability and Applications
    • /
    • v.9 no.2
    • /
    • pp.141-152
    • /
    • 2008
  • This paper presents equations, which can be used to evaluate the failure frequency and the failure rate of a two identical component parallel redundant system in which each component can operate in its wear out period, and the failure rate of each component is exponential power distribution. The optimum maintenance interval for a two identical component parallel redundant system can be obtained using these equations. The proposed approach is presented and illustrated using several numerical examples. The optimum maintenance interval for each component in a two identical parallel redundant system will depend on factors such as: failure rate, repair and maintenance times of each component in the parallel redundant systems.

  • PDF

Improved prediction of Pump Turbine Dynamic Behavior using a Thoma number dependent Hill Chart and Site Measurements

  • Manderla, Maximilian;Kiniger, Karl N.;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.63-72
    • /
    • 2015
  • Water hammer phenomena are important issues for the design and the operation of hydro power plants. Especially, if several reversible pump-turbines are coupled hydraulically there may be strong unit interactions. The precise prediction of all relevant transients is challenging. Regarding a recent pump-storage project, dynamic measurements motivate an improved turbine modeling approach making use of a Thoma number dependency. The proposed method is validated for several transient scenarios and turns out to improve correlation between measurement and simulation results significantly. Starting from simple scenarios, this allows better prediction of more complex transients. By applying a fully automated simulation procedure broad operating ranges of the highly nonlinear system can be covered providing a consistent insight into the plant dynamics. This finally allows the optimization of the closing strategy and hence the overall power plant performance.

A New Sponge of the Genus Haliclona (Gellius) (Haplosclerida: Chalinidae) from Gageodo Island (So-Huksando), Korea

  • Kim, Hyung-Jun;Sim, Chung-Ja
    • Animal cells and systems
    • /
    • v.8 no.4
    • /
    • pp.247-250
    • /
    • 2004
  • A taxonomic study on marine sponges was conducted by SCUBA diving at Gageodo Island, Korea from August 1999 to July 2001. Among them, Haliclona (Gellius) coreana n. sp. turned out to be new to science. This new species seems to be close to H. (G.) arcoferus Vosmaer, 1885, based on the type of spicules. However, it is different in size of toxa and growth form. Toxa of the new species is half in length compared to H. (G.) arcoferus. The growth form is jar shaped in this new species, but flat in H. (G.) arcoferus.

Dioxygen Transfer from 4a-Hydroperoxyflavin Anion to Isomeric Aminophenolates

  • Sam-Rok Keum;Ki-Bong Lee;Thomas C. Bruice
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.2
    • /
    • pp.95-99
    • /
    • 1990
  • The dioxygen transfer reaction from $N^5$-ethyl-4a-hydroperoxy-3-methyllumiflavin anion (4a-FlEtOO-) has been extended to isomeric aminophenol systems (1a-4a). O-aminophenol (o-AP, 1a & 2a) and p-aminophenol(p-AP, 3a & 4a) were turned out to be good substrates, whereas m-aminophenol(m-AP, 5a) was not. This is due to the charge location which is not on the carbon bearing the amino group. o-AO's react with 4a-FlEtOO- to give isophenoxazine derivatives (6 & 7) and with p-AP's to produce p-benzoquinone derivatives (8 & 9). The partition coefficients $(k_2/k_3)$ of 1a & 2a were $4.84{\times}10^{-4}\;&\;1.66{\times}10^{-5}M$, respectively and those of methylated aminophenolates, 2a & 4a were 4-10 times greater than nonmethylated substrates, 1a & 3a.

An Experiment Study for S/N Ratio of Bead Geometry for Guaranteeing the Welding Quality in Bellows Weld Joint (벨로우즈 용접부의 품질확보를 위한 비드형상 S/N비에 관한 실험적 연구)

  • Lee, Jong-Pyo;Kim, Ill-Soo;Park, Min-Ho;Jin, Byeong-Ju;Kim, In-Ju;Kim, Ji-Sun
    • Journal of Welding and Joining
    • /
    • v.35 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • The automatic welding systems, have received much attention in recent years, because they are highly suitable not only to increase the quality and productivity, but also to decrease manufacturing time and cost for a given product. Automatic welding work in semiconductor or space industry to be carried out in pipe line and butt joint mostly and plasma arc welding(PAW) is actively applied. To get the desired quality welds in automated welding system is challenging, a mathematical model is needed that has complete control over the relevant process parameters in order to obtain the required mechanical properties. However, In various industries the welding process mathematical model is not fully formulated for the process parameter and on the welding conditions, therefore only partial variables can be predicted. Therefore, this paper investigates the interaction between the welding parameters and mechanical properties for predicting the weld bead geometry by analyzing the S/N ratio.

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.

Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation (건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정)

  • Lee, Seung-No;Park, Se-Jun;Lee, In-Bok;Ha, Tae-Hwan;Kwon, Kyeong-Seok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Lee, Sang-Yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

A Study on the Effect of Surfactants in Acrylic Emulsion Polymerization (아크릴 에멀젼 중합에서의 계면활성제 영향에 관한 연구)

  • Song, Ju-Ho;Park, Sang-Joon;Park, Sang-Kwon;Lee, Myung-Cheon;Lim, Jong-Choo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.523-530
    • /
    • 1999
  • Acrylic pressure-sensitive adhesive has been made utilizing organic solvents, but nowadays it is made by solvent-free system due to environmental problems. In this study, emulsion polymerization were carried out at $40^{\circ}C$ with methacrylic acid(MAA), n-butyl acrylate(n-BA) and 2-ethylhexyl acrylate(2-EHA) as monomers in the presence of anionic(sodium dodecyl sulfate, SDS) and nonionic(ethylene oxide types) surfactant mixtures. The overall conversion of the polymerization reaction in a mixed surfactant system was found to be higher than that in a single surfactant system. Emulsion stability in mixed or anionic surfactant systems was found to be over 12 week, which was better than that in nonionic surfactant system. Emulsion particle size decreased as surfactant content increased. The Tg and molecular weight of emulsion polymer were inependent of the type, the amount and the mixing ratio of surfactant. Based on the results of stability and peel strength, the optimum nonionic surfactant ratio in total 4 g of surfactant mixture systems is found to be 40~60% by weight where the nonionic surfactant has 50 ethylene oxide groups and 16~18 carbon atoms in hydrophobic alkyl chain.

  • PDF

Cortisol and Fatty Acid Contents in Hanwoo Meat Produced by Antibiotics-free Rearing System (무항생제 사육방식으로 생산된 한우육내 코티졸과 지방산 함량)

  • Ha, Jae-Jung;Kim, Byung-Ki;Yi, Jun-Koo;Oh, Dong-Yep;Kim, Suk-Soo;Kim, Tae-Kyun;Chae, Hyung-Bok;Kim, Seung-Joon;Park, Young-Sik
    • Reproductive and Developmental Biology
    • /
    • v.38 no.3
    • /
    • pp.129-136
    • /
    • 2014
  • This study was carried out to elucidate the effect of antibiotic-free rearing system(ARS) on cortisol level, stress hormone, and fatty acid content in the edible muscle tissues, that were of M. longissimus in Hanwoo. These cattle were reared in two different systems including antibiotic-free (ARS) and conservative system (CRS). To increase the experimental reliability, the muscle samples were purchased 3 times from 3 Korean brands of beef produced with ARS or CRS. In the muscle tissue, cortisol level was significantly lower in ARS than CRS, (p=0.0176). But the levels of total saturated- and unsaturated-fatty acids were not significantly different between ARS and CRS (p>0.05). Of total fatty acids, the total saturated fatty acid tended to be greater in CRS and the total unsaturated fatty acid tended to be greater in ARS. However, of the total unsaturated fatty acids, the level of n-6 unsaturated fatty acids was significantly higher in ARS than CRS (p=0.0040). Especially, ${\alpha}$-linolenic acid (ALA) and ${\gamma}$-linolenic acid (GLA) levels were significantly higher in ARS (p<0.01). The n-6 fatty acid content and cortisol level in muscle tissue were negatively correlated at p=0.0140. In conclusion, ARS may produce beef with higher quality which contains lower cortisol and greater n-6 fatty acids, such as ALA and GLA.

Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials (TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성)

  • Kim, Y.U.;Cho, J.Y.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.