• 제목/요약/키워드: k-d 트리

Search Result 238, Processing Time 0.021 seconds

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Formation of Liquid Crystalline with Hydrogenated Lecithin and Its Effectiveness (수소첨가레시친을 이용한 액정 젤의 형성과 보습효과)

  • Kim, In-Young;Lee, Joo-Dong;Ryoo, Hee-Chang;Zhoh, Choon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.159-165
    • /
    • 2004
  • This study described about method that forms liquid crystal gel (LCG) by main ingredient with hydrogenated lechin (HL) in O/W emulsion system. Result of stability test is as following with most suitable LCG's composition. Composition of LCG is as following, to form liquid crystal, an emulsifier used 4.0wt% of cetostearyl alcohol (CA) by 4.0wt% of HL as a booster. Moisturizers contained 2wt% of glycerin and 3.0wt% of 1,3-butylene glycol (1,3-BG). Suitable emollients used 3.0wt% of cyclomethicone, 3.0wt% of isononyl isononanoate (ININ), 3.0wt% of cerpric/carprylic triglycerides (CCTG), 3.0wt% of macademia nut oil (MNO) in liquid crystal gel formation. On optimum conditions of LCG formation, the pHs were formed all well under acidity or alkalinity conditions (pH=4.0-11.0). Considering safety of skin, pH was the most suitable 6.0${\pm}$1.0 ranges. The stable hardness of LCG formation appeared best in 32 dyne/$\textrm{cm}^2$. Particle of LCG is forming size of 1-20$\mu\textrm{m}$ range, and confirmed that the most excellent LCG is formed in 1-6$\mu\textrm{m}$ range. According to result that observe shape of LCG with optical or polarization microscope, LCG could was formed, and confirmed that is forming multi -layer lamellar type structure around the LCG. Moisturizing effect measured clinical test about 20 volunteers. As a result, moisturizing effect of LCG compares to placebo cream was increased 36.6%. This could predicted that polyol group is appeared the actual state because is adsorbed much to round liquid crystal droplets to multi-lamellar layer's hydrophilic group. It could predicted that polyol group is vast quantity present phase that appear mixed because is adsorbed to round liquid crystal to multi-lamellar layer's hydrophilic group. This LCG formation theory may contribute greatly in cosmetics and pharmacy industry development.

Real-Time Hierarchical Techniques for Rendering of Translucent Materials and Screen-Space Interpolation (반투명 재질의 렌더링과 화면 보간을 위한 실시간 계층화 알고리즘)

  • Ki, Hyun-Woo;Oh, Kyoung-Su
    • Journal of Korea Game Society
    • /
    • v.7 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • In the natural world, most materials such as skin, marble and cloth are translucent. Their appearance is smooth and soft compared with metals or mirrors. In this paper, we propose a new GPU based hierarchical rendering technique for translucent materials, based on the dipole diffusion approximation, at interactive rates. Information of incident light, position, normal, and irradiance, on the surfaces are stored into 2D textures by rendering from a primary light view. Huge numbers of pixel photons are clustered into quad-tree image pyramids. Each pixel, we select clusters (sets of photons), and then we approximate multiple subsurface scattering term with the clusters. We also introduce a novel hierarchical screen-space interpolation technique by exploiting spatial coherence with early-z culling on the GPU. We also build image pyramids of the screen using mipmap and pixel shader. Each pixel of the pyramids is stores position, normal and spatial similarity of children pixels. If a pixel's the similarity is high, we render the pixel and interpolate the pixel to multiple pixels. Result images show that our method can interactively render deformable translucent objects by approximating hundreds of thousand photons with only hundreds clusters without any preprocessing. We use an image-space approach for entire process on the GPU, thus our method is less dependent to scene complexity.

  • PDF

Characteristic Analysis of Dredging and Sedimentation Debris Control Facilities in Inje, Gangwon (강원 인제지역 토석류 사방시설의 준설 및 퇴적 특성)

  • Park, Byungsoo;Jun, Sanghyun;Um, Jaekyung;Cho, Kwangjun;Yoo, Namjae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2013
  • 5 each permeable and impermeable debris dams were selected to analyze the characteristics of dredging and sedimentation according to facility type in Inje, Gangwon. Field tests for the ground water table and sedimentation characteristics of the selected dams were performed. Furthermore, data of the dredging amount, storage capacity, and drainage area were analyzed for the 51 more debris control facilities. From the results of field tests, it was found that the storage capacity of impermeable debris dam could be not enough when the large debris flow is produced since sediments are accumulated even if large debris flow was not occurred. Drainage can be a problem since the ground water table of impermeable debris dam was reached to the surface of ground. However, it was found that the ground saturation should not occur at heavy rain since ground water table of permeable debris dam was located in lower part of buttress. Furthermore, from the analysis results of relation among the dredging amount, basin area, and capacity of debris control facility, it was found that size of debris control facility was not reflected by the basin area. Effective planning and construction should be accomplished for the future since the real sedimentation amount was not significant even though large debris dams were constructed.

Soft-template Synthesis of Magnetically Separable Mesoporous Carbon (자성에 의해 분리 가능한 메조포러스 카본의 소프트 주형 합성)

  • Park, Sung Soo;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • In this study, we synthesized mesoporous carbon (Carbonized Ni-FDU-15) containing nanoporous structures and magnetic nanoparticles. Carbonized Ni-FDU-15 was synthesized via evaporation-induced self-assembly (EISA) and direct carbonization by using a triblock copolymer (F127) as a structure-directing agent, a resol precursor as a carbon-pore wall forming material, and nickel (II) nitrate as a metal ion source. The mesoporous carbon has a well-ordered two-dimensional hexagonal structure. Meanwhile, nickel (Ni) metal and nickel oxide (NiO) were produced in the magnetic nanoparticles in the pore wall. The size of the nanoparticles was about 37 nm. The surface area, pore size and pore volume of Carbonized Ni-FDU-15 were $558m^2g^{-1}$, $22.5{\AA}$ and $0.5cm^3g^{-1}$, respectively. Carbonized Ni-FDU-15 was found to move in the direction of magnetic force when magnetic force was externally applied. The magnetic nanoparticle-bearing mesoporous carbons are expected to have high applicability in a wide variety of applications such as adsorption/separation, magnetic storage media, ferrofluid, magnetic resonance imaging (MRI) and drug targeting, etc.

A Design Approach to $CrO_x/TiO_2$-based Catalysts for Gas-phase TCE Oxidation (기상 TCE 제거반응용 $CrO_x/TiO_2$계 복합 산화물 촉매 디자인)

  • Yang, Won-Ho;Kim, Moon-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.368-375
    • /
    • 2006
  • Single and complex metal oxide catalysts supported onto a commercial DT51D $TiO_2$ have been investigated for gas-phase TCE oxidation in a continuous flow type fixed-bed reaction system to develop a better design approach to catalysts for this reaction. Among the $TiO_2$-supported single metal oxides used, i.e., $CrO_x,\;FeO_x,\;MnO_x,\;LaO_x,\;CoO_x,\;NiO_x,\;CeO_x\;and\;CuO_x$, with the respective metal contents of 5 wt.%, the $CrO_x/TiO_2$ catalyst was shown to be most active for the oxidative TCE decomposition, depending significantly on amounts of $CrO_x\;on\;TiO_2$. The use of high $CrO_x$ loadings greater than 10 wt.% caused lower activity in the catalytic TCE oxidation, which is probably due to production of $Cr_2O_3$ crystallites on the surface of $TiO_2$. $CrO_x/TiO_2$-supported $CrO_x$-based bimetallic oxide catalysts were of particular interest in removal efficiency for this TCE oxidation reaction at reaction temperatures above $200^{\circ}C$, compared to that obtained with $CrO_x$-free complex metal oxides and a 10 wt.% $CrO_x/TiO_2$ catalyst. Catalytic activity of 5 wt.% $CrO_x-5$ wt.% $LaO_x$ in the removal reaction was similar to or slightly higher than that acquired for the $CrO_x$-only catalyst. Similar observation was revealed for 5 wt.% $CrO_x$-based bimetallic oxides consisting of either 5 wt.% $MnO_x,\;CoO_x,\;NiO_x\;or\;FeO_x$. These results represent that such $CrO_x$-based bimetallic systems for the catalytic TCE oxidation on significantly minimize the usage of $CrO_x$ that is well known to be one of very toxic heavy metals, and offer a very useful technique to design new type catalysts for reducing chlorinated volatile organic substances.

Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT (Spine SBRT 치료시 Coaxial MLC VMAT plan의 유용성 평가)

  • Son, Sang Jun;Mun, Jun Ki;Kim, Dae Ho;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.313-320
    • /
    • 2014
  • Purpose : The purpose of the study is to evaluate the efficiency of Coaxial MLC VMAT plan (Using $273^{\circ}$ and $350^{\circ}$ collimator angle) That the leaf motion direction aligned with axis of OAR (Organ at risk, It means spinal cord or cauda equine in this study.) compare to Universal MLC VMAT plan (using $30^{\circ}$ and $330^{\circ}$ collimator angle) for spine SBRT. Materials and Methods : The 10 cases of spine SBRT that treated with VMAT planned by Coaxial MLC and Varian TBX were enrolled. Those cases were planned by Eclipse (Ver. 10.0.42, Varian, USA), PRO3 (Progressive Resolution Optimizer 10.0.28) and AAA (Anisotropic Analytic Algorithm Ver. 10.0.28) with coplanar $360^{\circ}$ arcs and 10MV FFF (Flattening filter free). Each arc has $273^{\circ}$ and $350^{\circ}$ collimator angle, respectively. The Universal MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively. The calculation grid is 0.2 cm and all plans were normalized to the target V100%=90%. The indexes of evaluation are V10Gy, D0.03cc, Dmean of OAR (Organ at risk, It means spinal cord or cauda equine in this study.), H.I (Homogeneity index) of the target and total MU. All Coaxial VMAT plans were verified by gamma test with Mapcheck2 (Sun Nuclear Co., USA), Mapphan (Sun Nuclear Co., USA) and SNC patient (Sun Nuclear Co., USA Ver 6.1.2.18513). Results : The difference between the coaxial and the universal VMAT plans are follow. The coaxial VMAT plan is better in the V10Gy of OAR, Up to 4.1%, at least 0.4%, the average difference was 1.9% and In the D0.03cc of OAR, Up to 83.6 cGy, at least 2.2 cGy, the average difference was 33.3 cGy. In Dmean, Up to 34.8 cGy, at least -13.0 cGy, the average difference was 9.6 cGy that say the coaxial VMAT plans are better except few cases. H.I difference Up to 0.04, at least 0.01, the average difference was 0.02 and the difference of average total MU is 74.1 MU. The coaxial MLC VMAT plan is average 74.1 MU lesser then another. All IMRT verification gamma test results for the coaxial MLC VMAT plan passed over 90.0% at 1mm / 2%. Conclusion : Coaxial MLC VMAT treatment plan appeared to be favorable in most cases than the Universal MLC VMAT treatment planning. It is efficient in lowering the dose of the OAR V10Gy especially. As a result, the Coaxial MLC VMAT plan could be better than the Universal MLC VMAT plan in same MU.

A Study on the Moisturizing Effect and Preparation of Liquid Crystal Structures Using Sucrose Distearate Emulsifier (슈크로오스디스테아레이트를 사용한 액정구조의 생성과 보습효과에 관한 연구)

  • Kwak, Myeong-Heon;Kim, In-Young;Lee, Hwan-Myung;Park, Joo-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • This study is to make the liquid crystalline structure using sucrose distearate (Sucro-DS) emulsifier to create the hydrophilic type oil-in-water (O/W) emulsion, the droplets of the emulsion having a structure of a multi-lamellar structure. We have studied the physicochemical properties of Sucro-DS using those techniques. And it has been studied in the emulsion performance. In order to form the liquid crystalline structure applying 3 wt% of Sucro-DS, 5 wt% of glycerin, 5 wt% of squalane, 5 wt% of capric/caprylic triglyceride, 3wt% of cetostearyl alcohol, 1wt% of glyceryl mono-stearate, 78 wt% of pure water in mixture having the lamellar structure of stable multi-layer system was found to formed. By applying them, they were described how to create an unstable active material encapsulated cream. Further, the moisturizing cream was studied using this technique. It reported the results to the skin improvement effect by the human clinical trials. The pH range to produce a stable liquid crystal phase using a Sucro-DS was maintained in 5.2~7.5. In order to increase the stability of the liquid crystal, it was when behenyl alcohol containing 3 wt%, the hardness at this time was 13 kg/mm,min. Viscosity of the same amount was 25,000mPas/min. After a test for the effects of the emulsions, the concentration of 6 wt% Sucro-DS is that was appropriate, the particle size of the liquid crystal was 4~6mm. It was observed through a microscope analysis, reliability of the liquid crystal changes for 3 months was found to get stable at each $4^{\circ}C$, $25^{\circ}C$ and $45^{\circ}C$. In clinical trial test, before applying a moisturizing effect it was $13.4{\pm}7%$. Moisturizing cream liquid crystal was not formed in $14.5{\pm}5%$. Therefore, applying than ever before could see the moisture about 8.2% was improved. On the other hand, it was the moisturizing effect of the liquid cream is $19.2{\pm}7%$. The results showed that 43.3% improvement than that previously used. Applications fields, Sucro-DS emulsifier used liquid cream, lotion, eye cream and a variety of formulations can be developed, as well as the cosmetics industry is expected to be wide fields in the application of the external preparation for skin emulsion technology in the pharmaceutical industry and pharmaceutical industry.