• Title/Summary/Keyword: k-MVA

Search Result 247, Processing Time 0.034 seconds

Relationships Between Vessel-lumen-area Time Series of Quercus spp. at Mt. Songni and Corresponding Climatic Factors (속리산 참나무류 도관내강면적연대기와 기후인자와의 관계분석)

  • Jeong, Hyun-Min;Kim, Yo-Jung;Seo, Jeong-Wook
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.72-84
    • /
    • 2017
  • This study aimed to suggest a method to establish vessel-lumen-area chronologies in domestic Quercus spp. from Mt. Songni and to verify their potential as a climate proxy. In order to establish vessel-lumen-area chronologies, three options were applied to filter vessels. Options 1 and 2 use vessels having lumina larger than or equal to $6,000{\mu}m^2$ (MVA-60) and $7,500{\mu}m^2$ (MVA-75), respectively, to establish the chronologies by their mean values in each year, and option 3 uses the largest one (MAX) in each tree ring. MVA-60 and MVA-75 had mostly significant relationships with the winter precipitation between November in the previous year and January in the current year, however, MAX had only significant relationship with November precipitation in the previous year. Based on these results, it was verified that the potential of vessel lumina in domestic Quercus spp. could be a climate proxy in dendroclimatology.

3-D Analysis of Leakage Impedances in a 1MVA HTS Transformer (1MVA고온초전도 변압기의 3차원 누설임피던스 해석)

  • 김성훈;김우석;최경달;주형길;홍계원;한진호;한송엽
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.200-202
    • /
    • 2003
  • In this paper, 3-D electromagnetic analysis of a single phase 1MVA 22.9kV/6.6kV High Temperature Superconducting(HTS) transformer with double pancake windings by using the OPERA 3D was accomplished. And in order to perform the analysis of leakage impedances of a 1MVA HTS transformer, the energy conservation method was used. The efficiency voltage regulation and % impedance voltage drop of a 1MVA HTS transformer were obtained by the analysis of leakage impedances.

  • PDF

Analysis of AC Losses in 154 kV Class 5 MVA HTS Transformer (154 kV급 5 MVA 고온초전도 변압기의 교류손실)

  • Choi, Jee-Hoon;Lee, Seung-Wook;Kim, Woo-Seok;Lee, Ji-Kwang;Choi, Kyeong-Dal;Hahn, Song-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.146-147
    • /
    • 2007
  • 초전도체는 일반도체와 달리 직류 전류 인가 시에 저항이 발생하지 않지만 교류 전류 인가 시에는 히스테리시스에 의한 교류 손실이 발생한다. 이러한 초전도 선재를 이용하여 제작한 초전도 변압기에서 발생하는 교류손실은 변압기의 효율 감소 및 온도 상승으로 인해 초전도 변압기의 안정성을 저하시키는 요인으로 작용한다. 본 논문에서는 외철형의 구조를 갖는 154 kV급 5 MVA 고온 초전도 변압기를 YBCOCC 선재를 사용하여 설계하였다. 또한 2차원 수치해석을 통해 YBCOCC 선재의 자화 손실을 계산하고, 이를 154 kV급 5 MVA 고온 초전도변압기의 권선부에서 발생하는 수직 방향의 자장에 적용하여 변압기의 교류손실을 계산하고 그 결과를 나타내었다.

  • PDF

Design of a 33 MVA HTS Transformer with OLTC (OLTC를 고려한 33 MVA 초전도 변압기 설계)

  • Choi, J.H.;Lee, S.W.;Park, M.J.;Kim, W.S.;Choi, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

Design and Performance Evaluation for the 2MVA Water-Cooled PCU (2MVA 수냉형 PCU 설계 및 성능검증)

  • Kim, Sang-Hyun;Lim, Chang-jin;Han, Jong-Hee;Kim, Yun-hyun;Kim, Kwang-Seob
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.506-507
    • /
    • 2011
  • 본 논문에서는 신재생에너지의 에너지 백업용으로 사용되어지는 2MVA BESS(Battery Energy Storage System)의 수냉형 PCU(Power Conditioning Unit)을 설계하고 3D 모델링 및 열해석을 통해 열적 안정성을 확인하고 이를 실험으로서 검증한다.

  • PDF

An Analysis of Capacitance for a 2 MVA Mold Transformer (2MVA 몰드 변압기의 정전용량 계산)

  • Jang, Hyeong-Taek;Chung, Hyun-Koo;Kim, Yong-Bae;Woo, Sung-Hyun;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.674_675
    • /
    • 2009
  • 수치해석을 사용하여 2MVA 몰드 변압기의 정전용량을 시뮬레이션(FLUX 2D)하고 계산하였다. 산출한 정전 용량 값을 변압기 모델링 회로에 적용하여 switching surge 등 이상전압이 인가되었을 때 변압기 내부에 있는 권선들의 전압분포를 예상하고 절연설계에 적용 할 수 있음을 보였다.

  • PDF

The Application Study of 80MVA UPFC on the KEPCO Power System - Site Selection - (한전계통에서의 80MVA UPFC 적용연구(I) - 기대효과 분석 -)

  • Choo, Jin-Boo;Im, Sung-Ju;Chang, Byung-Hoon;Jeon, Young-Soo;Yun, Jong-Su;Oh, Kwan-Il
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.322-325
    • /
    • 2001
  • 본 논문은 한전의 "FACTS 계통운용 기술개발연구(II단계:80MVA UPFC 도입, 설치)" 연구과제에서 수행된 연구내용 중 위치결정의 배경 및 기대효과에 대한 사항을 일부 발췌하여 논문으로 작성하였다. 위 연구과제는 한전 전력연구원과 (주)효성 중공업연구소, 전기연구소, 기초연, 미국의 Siemens사가 공동으로 참여하여 80MVA UPFC(Unified Power Flow Controller) 시스템, 변압기, 통신장치 등을 제작, 설치하여 2003년 4월에 완료되는 과제이다. 전력연구원은 80MVA UPFC가 효율적이고. 경제적인 운용이 가능하도록, 한전 본사 관련부서와 협의, 전남지역의 154kV 강진변전소를 설치위치로 최종 결정하였다.

  • PDF

Performance Verification of IGCT GDU Power Supply System(HFI) for 100MVA STATCOM (100MVA STATCOM IGCT GDU 전원공급장치(HFI) 실증)

  • Han, Young-Seong;Chung, Chung-Choo;Choi, Jong-Yun;Park, Yong-Hee;Suh, In-Young;Yoo, Hyun-Ho;Kim, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.367-368
    • /
    • 2008
  • 한전 전력연구원이 주관하고 (주)효성이 참여하는 협동연구과제로 100MVA STATCOM(Static Compensator)개발이 수행 중에 있다. 100MVA STATCOM의 반도체 스위칭 소자로는 IGCT(Integrated Gate Commutated Thyristor)를 사용하고 있으며 IGCT GDU(Gate Deive Unit)의 전원공급용으로 HFI(High Frequency Inverter)를 사용한다. 본 논문에서는 설계 및 제작된 HFI를 실제 인버터 IGCT GDU전원 공급용으로 적용하여 확인한 성능에 대하여 기술하고 있다.

  • PDF

A study of excitation system of 500MVA short-circuit facilities (500MVA 단락발전기 여자시스템 특성 개선에 관한 고찰)

  • Jung, Heung-Soo;La, Dae-Ryeol;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun;Kim, Sun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.685-686
    • /
    • 2006
  • The excitation system of 500MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time current, short-circuit current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit facilities and the function and construction of each part.

  • PDF

Development of 1.5MVA wind power system model using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 고창 시험 설비 단지 1.5MVA 풍력 시스템 모델 개발)

  • Yun, Dong-Jin;Han, Byung-Moon;Choy, Young-Do;Jeon, Young-Soo;Jeong, Byoung-Chang;Chung, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.98-100
    • /
    • 2008
  • This study proposes a model of 1.5MVA wind power system in Go-chang field demonstration and performs simulation according to variable wind speed. 1.5MVA wind power system was verified by computer simulations with PSCAD/EMTDC software. Terminal voltage, grid voltage and active/reactive power can be observed through the simulation results.

  • PDF