• Title/Summary/Keyword: jump size

Search Result 59, Processing Time 0.021 seconds

Preparation and PTCR Characteristics of Semiconductive Nano (Ba1-xSbx)TiO3 Ceramic PowderS by Hydrothermal Process (수열합성법에 의한 반도성 나노 (Ba1-xSbx)TiO3 분말제조 및 PTCR 특성평가)

  • Choe, Yong-Gak;Lee, Jong-Hyeon;Lee, Hyeok-Hui;Won, Chang-Hwan
    • Korean Journal of Materials Research
    • /
    • v.12 no.3
    • /
    • pp.169-175
    • /
    • 2002
  • Semiconductive nano $(Ba_{1-x}Sb_x)TiO_3$ powders were synthesized by the hydrothermal process and Sb was simultaneously doped in the hydrothermal condition. $(Ba_{1-x}Sb_x)TiO_3$ powders obtained from optimum condition(at 20$0^{\circ}C$ for 3hr) exhibited spherical shape, high purity and nano size. The PTCR characteristics was observed when 0.1 and 0.2 mole% Sb were added and sintered at over 130$0^{\circ}C$ for 1 hour, respectively. And The ceramics exhibit the PTCR characteristics with a resistively jump $ratio($\rho$_{max}/$\rho$_{min})$ of about $10^4$. Also we found that PTCR characteristics were dependent on the microstructure.

Packet Output and Input Configuration in a Multicasting Session Using Network Coding

  • Marquez, Jose;Gutierrez, Ismael;Valle, Sebastian;Falco, Melanis
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.2
    • /
    • pp.686-710
    • /
    • 2019
  • This work proposes a model to solve the problem of Network Coding over a one-session multicast network. The model is based on a system of restrictions that defines the packet flows received in the sink nodes as functions of the outgoing flows from the source node. A multicast network graph is used to derive a directed labeled line graph (DLLG). The successive powers of the DLLG adjacency matrix to the convergence in the null matrix permits the construction of the jump matrix Source-Sinks. In its reduced form, this shows the dependency of the incoming flows in the sink nodes as a function of the outgoing flows in the source node. The emerging packets for each outgoing link from the source node are marked with a tag that is a linear combination of variables that corresponds to powers of two. Restrictions are built based on the dependence of the outgoing and incoming flows and the packet tags as variables. The linear independence of the incoming flows to the sink nodes is mandatory. The method is novel because the solution is independent of the Galois field size where the packet contents are defined.

RECENT DEVELOPMENT OF IMMERSED FEM FOR ELLIPTIC AND ELASTIC INTERFACE PROBLEMS

  • JO, GWANGHYUN;KWAK, DO YOUNG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.23 no.2
    • /
    • pp.65-92
    • /
    • 2019
  • We survey a recently developed immersed finite element method (IFEM) for the interface problems. The IFEM uses structured grids such as uniform grids, even if the interface is a smooth curve. Instead of fitting the curved interface, the bases are modified so that they satisfy the jump conditions along the interface. The early versions of IFEM [1, 2] were suboptimal in convergence order [3]. Later, the consistency terms were added to the bilinear forms [4, 5], thus the scheme became optimal and the error estimates were proven. For elasticity problems with interfaces, we modify the Crouzeix-Raviart based element to satisfy the traction conditions along the interface [6], but the consistency terms are not needed. To satisfy the Korn's inequality, we add the stabilizing terms to the bilinear form. The optimal error estimate was shown for a triangular grid. Lastly, we describe the multigrid algorithms for the discretized system arising from IFEM. The prolongation operators are designed so that the prolongated function satisfy the flux continuity condition along the interface. The W-cycle convergence was proved, and the number of V-cycle is independent of the mesh size.

A New ZVS Bi-directional CUK DC/DC Converter for a Car Dual Power Supply System (자동차 이중전원 시스템을 위한 새로운 ZVS 양방향 CUK DC/DC 컨버터)

  • Lee S. R.;Lee S. W.;Ko S. H.;Mun J. M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.355-358
    • /
    • 2004
  • Currently, to overcome the limit of a 14V power supply system and to enhance the stability of this system high and to make the fuel efficiency better, a research development of a 42V power supply system is actively the progress. As an intermediate step to change into an unity power supply system, a 42V/14V dual power supply system uses a DC/DC Converter as one of structure elements. Considering the main electric power sources in the next generation of the car is a 42V system a 14V power supply system has advantages as follows : In be managed efficiently and to increase the redundancy at start, to jump start with any vehicles, etc. We need the introduction of a hi-directional converter that can flow the energy each other in a dual 42V-l2V system. This paper proposed the ZVS hi-directional CUK DC/DC converter which decrease the weight with the size of the DC/DC Converter and minimize the loss when the switching happen. In this paper, a circuit design method and an action principle of the circuit was proposed. To verify the proposed circuit, a comprehensive evaluation with theoretical analysis, simulation results is presented.

  • PDF

Effect of Re-oxidation on the Electrical Properties of Mutilayered PTC Thermistors (적층 PTC 써미스터의 전기적 특성에 대한 재산화의 영향)

  • Chun, Myoung-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.2
    • /
    • pp.98-103
    • /
    • 2013
  • The alumina substrates that Ni electrode was printed on and the multi-layered PTCR thermistors of which composition is $(Ba_{0.998}Ce_{0.002})TiO_3+0.001MnCO_3+0.05BN$ were fabricated by a thick film process, and the effect of re-oxidation temperature on their resistivities and resistance jumps were investigated, respectively. Ni electroded alumina substrate and the multi-layered PTC thermistor were sintered at $1150^{\circ}C$ for 2 h under $PO_2=10^{-6}$ Pa and then re-oxidized at $600{\sim}850^{\circ}C$ for 20 min. With increasing the re-oxidation temperature, the room temperature resistivity increased and the resistance jump ($LogR_{290}/R_{25}$) decreased, which seems to be related to the oxidation of Ni electrode. The small sized chip PTC thermistor such as 2012 and 3216 exhibits a nonlinear and rectifying behavior in I-V curve but the large sized chip PTC thermistor such as 4532 and 6532 shows a linear and ohmic behavior. Also, the small sized chip PTC thermistor such as 2012 and 3216 is more dependent on the re-oxidation temperature and easy to be oxidized in comparison with the large sized chip PTC thermistor such as 4532 and 6532. So, the re-oxidation conditions of chip PTC thermistor may be determined by considering the chip size.

CCD PHOTOMETRY OF STANDARD STARS AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKSTAN: TRANSFORMATIONS AND COMPARISONS

  • Lim, Beomdu;Sung, Hwan-Kyung;Bessell, M.S.;Karimov, R.;Ibrahimov, M.
    • Journal of The Korean Astronomical Society
    • /
    • v.42 no.6
    • /
    • pp.161-174
    • /
    • 2009
  • Observation of standard stars is of crucial importance in stellar photometry. We have studied the standard transformation relations of the UBV RI CCD photometric system at the Maidanak Astronomical Observatory in Uzbekistan. All observations were made with the AZT-22 1.5m telescope, SITe 2k CCD or Fairchild 486 CCD, and standard Bessell UBV RI filters from 2003 August to 2007 September. We observed many standard stars around the celestial equator observed by SAAO astronomers. The atmospheric extinction coefficients, photometric zero points, and time variation of photometric zero points of each night were determined. Secondary extinction coefficients and photometric zero points were very stable, while primary extinction coefficients showed a distinct seasonal variation. We also determined the transformation coefficients for each filter. For B, V, R, and I filters, the transformation to the SAAO standard system could be achieved with a straight line or a combination of two straight lines. However, in the case of the U filter and Fairchild 486 CCD combination, a significant non-linear correction term - related to the size of Balmer jump or the strength of the Balmer lines - of up to 0:08 mags was required. We found that our data matched well the SAAO photometry in V, B - V, V - I, and R - I. But in U - B, the difference in zero point was about 3.6 mmag and the scatter was about 0.02 mag. We attribute the relatively large scatter in U -B to the larger error in U of the SAAO photometry. We confirm the mostly small differences between the SAAO standard UBV RI system and the Landolt standard system. We also attempted to interpret the seasonal variation of the atmospheric extinction coefficients in the context of scattering sources in the earth's atmosphere.

Power Test of Trend Analysis using Simulation Experiment (모의실험을 이용한 경향성 분석기법의 검정력 평가)

  • Ryu, Yongjun;Shin, Hongjoon;Kim, Sooyoung;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.3
    • /
    • pp.219-227
    • /
    • 2013
  • Time series data including change, jump, trend and periodicity generally have nonstationarity. Especially, various methods have been proposed to identify the trend about hydrological time series data. However, among various methods, evaluation about capability of each trend test has not been done a lot. Even for the same data, each method may show the different result. In this study, the simulation was performed for identification about the changes in trend analysis according to the statistical characteristics and the capability in the trend analysis. For this purpose, power test for the trend analysis is conducted using Men-Kendall test, Hotelling-Pabst test, t test and Sen test according to the slope, sample size, standard deviation and significance level. As a result, t test has higher statistical power than the others, while Mann-Kendall, Hotelling-Pabst, and Sen tests were similar results.

Bandwidth selections based on cross-validation for estimation of a discontinuity point in density (교차타당성을 이용한 확률밀도함수의 불연속점 추정의 띠폭 선택)

  • Huh, Jib
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.4
    • /
    • pp.765-775
    • /
    • 2012
  • The cross-validation is a popular method to select bandwidth in all types of kernel estimation. The maximum likelihood cross-validation, the least squares cross-validation and biased cross-validation have been proposed for bandwidth selection in kernel density estimation. In the case that the probability density function has a discontinuity point, Huh (2012) proposed a method of bandwidth selection using the maximum likelihood cross-validation. In this paper, two forms of cross-validation with the one-sided kernel function are proposed for bandwidth selection to estimate the location and jump size of the discontinuity point of density. These methods are motivated by the least squares cross-validation and the biased cross-validation. By simulated examples, the finite sample performances of two proposed methods with the one of Huh (2012) are compared.

MULTI-SCALE MODELING AND ANALYSIS OF CONVECTIVE BOILING: TOWARDS THE PREDICTION OF CHF IN ROD BUNDLES

  • Niceno, B.;Sato, Y.;Badillo, A.;Andreani, M.
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.620-635
    • /
    • 2010
  • In this paper we describe current activities on the project Multi-Scale Modeling and Analysis of convective boiling (MSMA), conducted jointly by the Paul Scherrer Institute (PSI) and the Swiss Nuclear Utilities (Swissnuclear). The long-term aim of the MSMA project is to formulate improved closure laws for Computational Fluid Dynamics (CFD) simulations for prediction of convective boiling and eventually of the Critical Heat Flux (CHF). As boiling is controlled by the competition of numerous phenomena at various length and time scales, a multi-scale approach is employed to tackle the problem at different scales. In the MSMA project, the scales on which we focus range from the CFD scale (macro-scale), bubble size scale (meso-scale), liquid micro-layer and triple interline scale (micro-scale), and molecular scale (nano-scale). The current focus of the project is on micro- and meso-scales modeling. The numerical framework comprises a highly efficient, parallel DNS solver, the PSI-BOIL code. The code has incorporated an Immersed Boundary Method (IBM) to tackle complex geometries. For simulation of meso-scales (bubbles), we use the Constrained Interpolation Profile method: Conservative Semi-Lagrangian $2^{nd}$ order (CIP-CSL2). The phase change is described either by applying conventional jump conditions at the interface, or by using the Phase Field (PF) approach. In this work, we present selected results for flows in complex geometry using the IBM, selected bubbly flow simulations using the CIP-CSL2 method and results for phase change using the PF approach. In the subsequent stage of the project, the importance of effects of nano-scale processes on the global boiling heat transfer will be evaluated. To validate the models, more experimental information will be needed in the future, so it is expected that the MSMA project will become the seed for a long-term, combined theoretical and experimental program.

Impact of Wearing Functional Supporters that Prevent Seniors from Falling on Muscle Function, Sense of Balance, and Overcoming Fatigue (시니어 낙상예방을 위한 기능성 서포터 착용에 따른 근기능 및 균형감각과 피로회복에 미치는 영향 연구)

  • Um, Sungheum;Jang, Seonu;Park, Munhwan;Lee, Seongjae
    • Fashion & Textile Research Journal
    • /
    • v.24 no.1
    • /
    • pp.156-163
    • /
    • 2022
  • Loss of leg muscle and muscle weakness, which are caused by aging, affect muscle function and sense of balance. As a way of preventing seniors from falling, we developed the idea of wearing functional supporters based on graduated compression technique and in the form of a taping supporter. Their impact on power, sense of balance, overcoming fatigue, and subjective wearing sensation was investigated. The following results were obtained. After wearing functional compression supporters, body temperature increased from 24.5 ± 0.5℃ to 26.3 ± 0.6℃. Calf size, which assesses the level of edema, decreased from 26.1 ± 1.8cm to 25.7 ± 1.8cm. The result of dynamic balance test, which helps estimate the fall prevention effect, increased from 6.4 ± 0.9sec to 7.1 ± 0.6sec. Lactate level, which indicates the level of fatigue, decreased from 8.1 ± 0.6mmol/L to 7.3 ± 0.8mmol/L. Standing long jump record, which assesses power, increased from 110.1 ± 3.1cm to 112.0 ± 2.8cm. Standing on one leg with eyes closed, which assesses sense of balance, increased from 4.2 ± 1.1sec to 6.5 ± 0.8sec. Ankle angle, which assesses joint stability, increased from 75.3 ± 4.0° to 80.1 ± 1.7°. In metabolism and physical performance testing, which assesses keep, the score increased from 26.3 ± 1.7 to 28.8 ± 1.2. Muscle supporting score, which assesses joint stability, increased from 7.3 ± 0.6 to 7.8 ± 0.4. In the category of body type, which assesses wearing sensation and body shaping function, the score increased from 5.7 ± 1.4 to 6.4 ± 1.2