• Title/Summary/Keyword: juice HACCP

Search Result 5, Processing Time 0.026 seconds

The Hazard Analysis and Critical Control Point (HACCP) System and Its Implementation in an Aseptic Thermal Juice Processing Scheme: A Review

  • Min, Sea-Cheol;Min, David B.
    • Food Science and Biotechnology
    • /
    • v.15 no.5
    • /
    • pp.651-663
    • /
    • 2006
  • Hazard Analysis and Critical Control Point (HACCP), a systematic process that identifies, assesses, and controls hazards, has been developed as an effective alternative to conventional end-point analysis for food safety control. The importance of HACCP has been emphasized recently due to the development of new food processing technologies and the increase in international trade demanding worldwide of food product safety. This paper provides a review of HACCP and a generic HACCP template for its implementation for aseptic processing of a juice drink.

Detection of Staphylococcus aureus and Screening Staphylococcal Enterotoxin a, b, c genes in Strains Isolated from Strawberry Juice Shops in Jinju (진주 지역 딸기 주스 상점에서의 Staphylococcus aureus의 분리와 staphylococcal enterotoxin a, b, c gene 검색)

  • Kim, Se-Ri;Park, Seon-Ja;Shim, Won-Bo;Kim, Hyoung-Kab;Chung, Duck-Hwa
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 2005
  • Staphylococcus aureus is one of the important pathogenic agents, which are related to the hygienic condition. This study performed for the detection of Staphylococcus aureus and screening staphylococcal enterotoxin a, b, c genes in strains isolated from the environment for production of non-pasteurized strawberry juice. A total of 44 samples were collected from utensils, machinery, employees, raw materials, and strawberry juices in 3 strawberry juice shops in Jinju, western Gyeongnam. The isolation rate of Staphylococcus aureus was 26%. Specially Staphylococcus aureus was frequently isolated from employee's hands, strawberry and strawberry juices. The sea, seb, and sec genes were also investigated by polymerase chain reaction (PCR). One hundred and 55% of each isolate had found sea gene and seb gene, respectively. However, sec gene was not detected anywhere. To prevent food-borne disease associated with juice, the accomplishment of HACCP to be more efficient and systematic is necessary.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Microbiological Evaluation for HACCP System Application of Green Vegetable Juice Containing Lactic Acid Bacteria (유산균을 함유한 녹즙의 HACCP 시스템 적용을 위한 미생물학적 위해도 평가)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4924-4931
    • /
    • 2011
  • This research performed to evaluate a production processes reporting by the HACCP system of green vegetable juice products, containing lactic acid bacteria, stage of processing raw materials agricultural products and production facilities of general bacteria and pathogenic micro organism. General bacteria are found from four samples of storage of agricultural products at process stage and water was detected 8.67~14.67 CFU/ml. However, all samples were detected less than 105 CFU/ml as a legal standards after the process of UV sterilization. For the outcome of experiment of E.coli, E.coli O157:H7, B.cereus, L.moonocytogenes, Salmonella spp, Staph.aureus as the food poisoning bacterial, E.coli was detected until UV pre-step process in storage process and B.cereus was detected partly till 1st washing. Since all bacterial, Yeast and Mold are detected in main materials, pre-control method is a necessary to establish for decreasing with a number of initial bacteria of main materials and it is considered to establish the effective ways of washing and sterilization such as production facilities for cross contamination prevention of bacteria and Sthaphylococcus. Based on above results, the process of UV sterilization should be managed with CCP as an important process to reduce or eliminate the general and food poisoning bacterial of green vegetable juice products, including lactic acid bacteria. Therefore, it is considered to need an exhaustive HACCP plan such as control manual of UV sterilization, solution method, verification, education and training and record management.

Investigation of the Level of Microbial Contamination in the Environment for Juice Production (생딸기 주스 제조 환경에서의 미생물학적 오염도 조사)

  • Kim, Se-Ri;Shim, Won-Bo;Park, Seon-Ja;Ha, Kwang-Soo;Yoon, Hae-Suk;Ha, Sang-Do;Kim, Keun-Sung;Lee, Kyu-Ho;Kim, Min-Gon;Kim, Kwang-Yup;Kim, Cheol-Ho;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.287-293
    • /
    • 2005
  • Microbial contamination levels in commercial strawberry juices were examined for sanitary indication bacteria, such as aerobic plate count (APC), coliforms, and Escherchia coli, and pathogenic bacteria such as E. coli O157:H7, Salmonella spp., Staphylococcus aureus, and Listeria monocytogenes. APC and coliform count ranged 0-5.2 and $0-2.8\;log_{10}\;CFU/(mL,\;g,\;100cm^{2},\;hand)$, respectively, and 80% strawberry juices were contaminated with E. coli and S. aureus, detected at 19%, was found in employee's hands, strawberries, and strawberry juices, whereas E. coli O157:H7, Salmonella spp, and L. monocytogenes were not detected. These results will provide microbiological information for introduction of Hazard Analysis Critical Control Point (HACCP) system in juice shops.