• Title/Summary/Keyword: joint measurement

Search Result 803, Processing Time 0.028 seconds

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

The Effect of Cement Milk Grouting on the Deformation Behavior of Jointed Rock Mass (시멘트현탁액 주입에 의한 절리암반의 역학적 특성 변화)

  • 김태혁;이정인
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.331-343
    • /
    • 2003
  • Though the Grouting has been in use for a long time, it is still regarded as an technique rather than engineering. The study of ground improvement by grouting is rare especially in jointed rock mass. In this study, biaxial compression tests were performed in the jointed rock mass models with .ough surfBce joints assembled with blocks before and after grouting. The load-deformation curves of the jointed rock masses showed a non-linear relationship before grouting but showed a relatively linear deformaion behavior after grouting. Improvement ratio (deformation modulus after grouting/deformation modulus before grouting) decreased with increasing joint spacing and lateral stress. Improvement ratio decreased exponentially with increasing deformation modulus of the rock mass model before grouting. Three-dimensional FDM analysis was performed to a highway tunnel case using experimental data of grouted rock. The convergence of the tunnel predicted after grouting by the numerical modelling coincided with those attained from the field measurement.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

Effects of Geological Conditions on the Geomorphological Development of the Southwestern Coastal Regions of Korea (서남해안지역(西南海岸地域)의 지형발달(地形發達)에 미친 지질조건(地質條件))

  • Kim, Suh Woon
    • Economic and Environmental Geology
    • /
    • v.4 no.1
    • /
    • pp.11-18
    • /
    • 1971
  • The geotectonics and geomorphic structure of Korea resulted from the Song-rim Disturbance and the Daebo orogenic movements. Afterward this mountainous peninsula underwent several geological changes on a small scale, and it was also claimed that the steady rising of the elevated peneplain of the eastern coast and the submerging of the southwestern coastal area are largely due to the tilted block movement. These views have been generally accepted good in several ways, but they are limited in range or lacking in theoretical integration. The present writer investigated the geology of the Mt. Chi-ri-san and the Honam coal mining area for a geological map in 1965, respectively. The results of these studies convinced the present writer that the conventional views, which were based upon a theory of lateral pressure should be reconsidered in many respects, and more recent studies made it clear that the morphological development in the southwestern area can be better explained by the orogenic movement and rock control. The measurement of submerging speed of the western coastal area (Pak. Y. A., 1969) and a new account on the geology and tectonics of the Mid-central region of South Korea (Kim O.J., 1970) act as an encouragement to a new explanation. The present writer's researches on the extreme southwestern portion of the peninsula show that the steady submerging of this area cannot be attributed to a simple downthrown block phenomenon caused by block movement. It is no more than the result of the differential movement of uplifting in the eastern and western coastal areas and the rising of sea-level in the post-glacial period. This phenomenon could be easily explained by the comparison of the rate of rise in sea-level and amount of heat flow between Korea and other areas in the world. The existance of the erosional planes in the Sobaik-San ranges also provide an evidence of an upheaval in the western coast area. Though the Sobaik-San ranges largely follow the direction of the Sinian system. They consist of the numerous branches, whose trends run more or less differently from their main trend because of the disharmonic folding, are converged into Mt. Sobaik-San and Chupungryung. The undulation of the land is not wholely caused by orogenic movements, where as the present writer confirmed that the diversity of morphological development is the direct reflection of geological conditions such as rocks and processes which constitute the basic elements of geomorphic structure. An east-west directed mountain range which could be named as Hansan mountain range, was claimed to be oriented by the joint control. The geological conditions such as a special erosion and weathering of agglomerate and breccia tuff usually produce pot-hole like submarine features which cause the whirling phenomenon at the southwestern coast channel.

  • PDF

A Robust Depth Map Upsampling Against Camera Calibration Errors (카메라 보정 오류에 강건한 깊이맵 업샘플링 기술)

  • Kim, Jae-Kwang;Lee, Jae-Ho;Kim, Chang-Ick
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.6
    • /
    • pp.8-17
    • /
    • 2011
  • Recently, fusion camera systems that consist of depth sensors and color cameras have been widely developed with the advent of a new type of sensor, time-of-flight (TOF) depth sensor. The physical limitation of depth sensors usually generates low resolution images compared to corresponding color images. Therefore, the pre-processing module, such as camera calibration, three dimensional warping, and hole filling, is necessary to generate the high resolution depth map that is placed in the image plane of the color image. However, the result of the pre-processing step is usually inaccurate due to errors from the camera calibration and the depth measurement. Therefore, in this paper, we present a depth map upsampling method robust these errors. First, the confidence of the measured depth value is estimated by the interrelation between the color image and the pre-upsampled depth map. Then, the detailed depth map can be generated by the modified kernel regression method which exclude depth values having low confidence. Our proposed algorithm guarantees the high quality result in the presence of the camera calibration errors. Experimental comparison with other data fusion techniques shows the superiority of our proposed method.

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

Comparison of General Test Methods of Various Organs on Synthetic Food Colors (여러 기관의 일반시험법에 의한 식용 타르색소의 규격 비교 시험)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Hong Ki-Hyoung;Park Sung-Kwan;Choi Duck-Jang;Kim Hee-Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.1
    • /
    • pp.64-68
    • /
    • 2005
  • An analytical method of nine synthetic foods colors in Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA were compared. Contents of water insoluble matter in synthetic food colors tested were not different by general test methods of various organs. Contents of chloride and sulfate salts in Food Green No.3, Food Red No.3, Food Blue No.2, and Food Yellow No.4 slightly differed in various methods, and but up to the standard, and general test methods of JECFA and USA needed far more time. For the measurement of arsenic contents in food colors, colorimetric method in Korea and Japan, and silver diethyldithiocarbamate colorimetric method in USA and JECFA were used, but the standards of them were different. Content of heavy metals was up to the standard, but the methods were used colorimetric method in Korea, atomic absorption method in Japan, and both methods in JECFA and USA.

Evaluation of Stiffness Profile for a Subgrade Cross-Section by the CAP(Common-Array-Profiling)-SASW Technique (CAP SASW 기법에 의한 지반단면의 전단강성구조 평가)

  • Joh Sung-Ho;Jang Dae-Woo;Kang Tae-Ho;Lee Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.71-81
    • /
    • 2005
  • Surface wave techniques were initially based on 2-D plane waves and were later improved to the techniques based the 3-D based cylindrical waves. However, body-wave interference, near-field effect and limited technology in surface wave measurements restricted the use of 3-D cylindrical waves to the 1-D evaluation of subgrade stiffness. In this study, by the numerical simulation of SASW measurements, the dispersion properties of surface waves including vertical, horizontal Rayleigh waves and Love waves were thoroughly investigated in the 3-D domain, and a new filter criteria to minimize the near-field effect was established, which led to CAP (common-array-profiling)-SASW technique. The CAP-SASW technique enabled the evaluation of subgrade stiffness fur a specific subgrade segment, not for a whole section of measurement array. Therefore, a contour plot of subgrade stiffness with a ground-truth quality can be obtained by the CAP-SASW technique. The procedure proposed in this study was verified by comparing the shear-wave velocity profiles with the shear-wave velocity profiles of downhole testing at two geotechnical sites.

Effect of Therapeutic Gymnastic Ball Exercise in Patients With Chronic Low Back Pain (만성 요통환자의 치료를 위한 치료용 볼 운동의 효과)

  • Lee, Eun-Young;Bang, Yoo-Soon;Ko, Ja-Kyung
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.109-126
    • /
    • 2003
  • This study was designed 10 investigate the effects of therapeutic gymnastic ball exercise on pain, flexibility, lumbar disability level and daily activity levels in male patients of the armed forces medical hospital who complain of chronic low back pain. Twenty-three males were placed in the experimental group and twenty-nine males were placed in the control group. All of the subjects were chosen on the basis of availability among in-patients who were diagnosed with low back pain. The control patients were matched to the experimental group and they were selected considering gender, pain duration and age. Gymnastic ball exercise therapy was developed by the author with the assistance of a rehabilitation specialist. Gymnastic ball exercise therapy includes muscle relaxation, flexibility, muscle strength and posture development exercises. The gymnastic ball exercise therapy was carried out by the experimental group three times a week for eight weeks. Before and after the experiments, the intensity of pain, the lumbar joint mobility (flexibility), the lumbar disability levels, and the daily activity levels of the subjects were measured, respectively. The intensity of pain and the lumbar disability levels were measured by the Visual Analogue Scale, the level of flexibility by a measurement ruler, and the level of disability by the Oswestry Low Back Pain Disability Scale. Data were analysed using a t-test, a paired t-test and an unpaired t-test. The results were as follows: 1. The intensity of pain in the lumbar spine in the experimental group was significantly decreased compared with that of the control group during the 4th week and 8th week. 2. The flexibility of the lumbar spine in the experimental group was significantly increased compared with that of the control group during the 4th week and 8 week. 3. The level of pain caused by anterior, posterior, left lateral and right lateral bending and by rotation in experimental group was significantly decreased compared with that of the control group. 4. The Oswestry Disability score of the experimental group was significantly increased compared with that of control group. These findings indicate that gymnastic ball exercise therapy could be effective in decreasing pain and lumbar disability, and increasing the daily activity levels and lumbar flexibility in patients with chronic low back pain. The study also suggests that gymnastic ball exercise therapy could be an essential factor for effective nursing intervention for patients suffering from chronic low back pain.

  • PDF