• Title/Summary/Keyword: joint length

Search Result 1,035, Processing Time 0.024 seconds

Numerical Analysis of Groundwater Flow through Fractured Rock Mass by Tunneling in a Mountainous Area (산악 지역 내 터널 굴착 시 단열 암반 내 지하수 유동 분석)

  • Kim, Hyoung-Soo;Lee, Ju-Hyun;Ahn, Ju-Hee;Ahn, Gyu-Cheon;Yoon, Woon-Sang
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.281-287
    • /
    • 2006
  • Intake of groundwater by tunneling in a mountainous area mostly results from groundwater flow through fractured parts of total rock mass. For reasonable analysis of this phenomenon the representative joint groups 1, 2, and 3 have been selected by previous investigations, geological/geophysical field tests and boring works. Three dimensional fractures were generated by the FracMan and MAFIC which is a three dimensional finite element model has been used to analyse a groundwater flow through fractured media. Monte Carlo simulation was applied to reduce the uncertainty of this study. The numerical results showed that the average and deviation of amounts of groundwater intaked into tunnel per unit length were $5.40{\times}10^{-1}$ and $3.04{\times}10^{-1}m^3/min/km$. It is concluded that tunnel would be stable on impact of groundwater environment by tunneling because of the lower value than $2.00{\sim}3.00m^3/min/km$ as previous and present standard on the application of tunnel construction.

The comparison of two different intraarticular injections using a sonographic anterolateral approach in patients with osteoarthritic knee

  • Choi, Jin Wook;Lee, Jun Ho;Ki, Minjong;Kim, Myung Jong;Kang, Sehrin;Lee, Juhyung;Lee, Jun-Rae;Han, Young-Jin;Son, Ji-Seon
    • The Korean Journal of Pain
    • /
    • v.31 no.4
    • /
    • pp.289-295
    • /
    • 2018
  • Background: The intraarticular (IA) injection has become popular for the management of the osteoarthritic knee without an effusion. The success rate of IA injection would be better if it was able to be visually confirmed. We hypothesized that an anterolateral approach, which targets the synovial membrane of the lateral condyle using ultrasound, would provide an equivalent alternative to the anterolateral approach, targeting the synovial membrane of the medial condyle for IA injection of the knee. Methods: A total of 96 knees with osteoarthritis were randomized placed into the two groups, which were group I (anterolateral approach to the medial condyle) and group II (anterolateral approach to the lateral condyle). The primary outcome was to compare the success rate of the two methods of IA injection. The required length of the needle for injection was also measured and compared. Pain intensity was assessed using the Numeric Rating Scale in order to evaluate the success of injection. Results: There were no significant differences in the success rate between both groups. The success rate of group I and group II were 87.8% (95%, CI 78.7-97.0) and 91.5% (95%, CI 83.6-99.5), respectively (P = 0.549). The needle depth was $5.0{\pm}0.8$ (3.0 to 6.1 cm) in group I, and $3.0{\pm}0.8$ (1.5 to 5 cm) in group II (P < 0.001). Conclusions: The anterolateral approach to the lateral femoral condyle, using ultrasound, is an alternative method to the approach targeting the medial femoral condyle, using shorter needle.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Evaluation of Buckling Load and Specified Compression Strength of Welded Built-up H-section Compression Members with Residual Stresses (잔류응력의 영향을 고려한 조립 H-형강 부재의 좌굴하중 및 설계압축강도 평가)

  • Lee, Soo-Keuon;Yang, Jae-Guen;Kang, Ji-Seok
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.81-88
    • /
    • 2017
  • Residual stress is defined as stress that already exists on a structural member from the effects of welding and plastic deformation before the application of loading. Due to such residual stress, welded H-section compression members under centroidal compression load can undergo buckling and failure for strength values smaller than the predicted buckling load and specified compressive strength. Therefore, this study was carried out to evaluate the effect of residual stress from welding on the determination of the buckling load and specified compressive strength of the H-section compression member according to the column length variation. A three-dimensional nonlinear finite element analysis was performed for the H-section compression member where the welded joint was fillet welded by applying heat inputs of 3.1kJ/mm and 3.6kJ/mm using the SAW welding method.

Establishment of Rebar Quantity Estimation in BIM-based Initial Design Phase (BIM기반 초기 설계 단계 철근 물량 산출 프로세스 구축)

  • Song, Chi-Ho;Kim, Chee-Kyeong;Lee, Si Eun;Choi, Hyunchul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.447-454
    • /
    • 2016
  • In the meantime, looking at the present status of how to estimationte the quantity of rebar based on 3D BIM getting the limelight in these days, commercial BIM tools provide rebar modeling functions however it takes a vast amount of modeling time for modeling of rebar in use of that function hence there is no BIM software at present for practical use. Therefore, in this study, we organized and presented a practical rebar quantity estimationtion process in BIM-based design work-site and intended to develop a program named Rebar Automatic Arrangement Program - hereinafter called RAAP - which enables automatic rebar arrangement based on much more precise cross-sectional information of bars in column, beam, slab and wall than the one from existing 2D method under the conditions without any cross-sectional information in the initial design phase. In addition, we intended to establish rebar quantity estimationtion process in the initial design phase through interworking of modeling & quantity estimationtion functions in consideration of joint, anchoring length of BuilderHUB as a BIM software with RAAP. The results from this study are practical in developing a technology that is able to estimationte quantity with more improved reliability than the one from existing 2D-based methods with less effort when the quantity of framework is estimationted in the uncompleted state of cross-sectional design for structural members in the initial design phase of a construction project. And it is expected that it could be utilized as a basic study from which a reasonable quantity estimationtion program can be established in the initial design phase.

Osteosarcoma in an 8 Month-Old Infant treated with Limb Sparing Operation (8개월된 유아 골육종 환자에서의 사지 보존술)

  • Kim, Jae-Do;Kwon, Young-Ho;Kang, Myung-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.100-104
    • /
    • 2005
  • Osteosarcoma is the most common tumor in malignant bone tumors. The peak age incidence in osteosarcoma is between 10 to 14 years of age. This tumor rarely develops under 6 years of age and the youngest patient in the previous literature was a 13 months old girl who had an osteosarcoma involving the second metacarpal bone. We report a case of an 8 month old male infant, who had an osteosarcoma involving the right proximal tibia. This patient was treated by wide excision with transepiphyseal resection and reconstruction with allograft. At 20 months after operation, the varus deformity was developed at the proximal junctional site of allograft. Thereafter, the revision was performed with correction of deformity and augmentation with the proximal fibula transfer. At 51 months after operation, he has been remained as free of disease, and he has recovered the knee motion ranged from 15 degree to 75 degree. The osteosarcoma in infant is very rare but it should be considered the osteosarcoma in the differential diagnosis of any bone lesion. Instead of amputation, the limb sparing operation and the solutions for limb length inequility in growing period should be carefully considered in the infantile osteosarcoma.

  • PDF

Association between Polymorphisms in UDP-glucuronosyltransferase 1A6 and 1A7 and Colorectal Cancer Risk

  • Osawa, Kayo;Nakarai, Chiaki;Akiyama, Minami;Hashimoto, Ryuta;Tsutou, Akimitsu;Takahashi, Juro;Takaoka, Yuko;Kawamura, Shiro;Shimada, Etsuji;Tanaka, Kenichi;Kozuka, Masaya;Yamamoto, Masahiro;Kido, Yoshiaki
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2311-2314
    • /
    • 2012
  • Genetic polymorphisms of uridine diphosphate-glucuronosyltransferases 1A6 (UGT1A6) and 1A7 (UGT1A7) may lead to genetic instability and colorectal cancer carcinogenesis. Our objective was to measure the interaction between polymorphisms of these repair genes and tobacco smoking in colorectal cancer (CRC). A total of 68 individuals with CRC and 112 non-cancer controls were divided into non-smoker and smoker groups according to pack-years of smoking. Genetic polymorphisms of UGT1A6 and UGT1A7 were examined using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). We found a weak association of UGT1A6 polymorphisms with CRC risk (crude odds ratio [OR], 1.65;95% confidence interval [95% CI], 0.9-3.1, P=0.107; adjusted OR 1.95%, 95% CI 1.0-3.8, P=0.051). The ORs for the UGT1A7 polymorphisms were statistically significant (crude OR: 26.40, 95% CI: 3.5-198.4, P=0.001; adjusted OR: 21.52, 95% CI: 2.8-164.1, P=0.003). The joint effect of tobacco exposure and UGTIA6 polymorphisms was significantly associated with colorectal cancer risk in non-smokers (crude OR, 2.11; 95% CI, 0.9-5.0, P=0.092; adjusted OR 2.63, 95% CI, 1.0-6.7, P=0.042). In conclusion, our findings suggest that UGT1A6 and UGT1A7 gene polymorphisms are associated with CRC risk in the Japanese population. In particualr, UGT1A6 polymorphisms may strongly increase CRC risk through the formation of carcinogens not associated with smoking.

Improving of the Fishing Gear and Development of the Automatic Operation System in the Anchovy Boat Seine- II Analysis of escaping behaviour of anchovy in relation to underwater light and towing flow velocity (기선권현망어업의 어구개량과 자동화조업시스템 개발- II 수중광 및 예망유속과 멸치의 도피반응 행동 분석)

  • 김용해;장충식;안영수;김형석
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.78-84
    • /
    • 2001
  • Escape behaviour of the anchovy (Engralius japonica, total length 4-7cm) at the inside wing net and bag net in the anchovy boat seine was observed by underwater video camera in order to clarify the relationship between visual stimulus of the gear or relative water flow inside gear and reacting behaviour. The vertical attenuation coefficient of underwater illuminance in the offshore of Keoje island and Tongyoung was ranged from 0.24 to 1.03 and it could be affect visual range and visual contrast of the fishing gear. The relative water flow at the joint part between inside wing and bagnet while towing was 1.5 times higher than at the middle part of inside wing or fore part of bag net, but it was estimated under than maximum swimming speed of 4-7 cm anchovy. The mean escaping number of anchovy from end part of inside wing of 30 cm mesh to out side for a minute within visual range of video camera was 455 and anchovy swimming forward from bag net through flapper was 308. These results revealed anchovy could escape as voluntary response in spite of higher visual stimulus or higher water flow.

  • PDF

The Motion Response of an Oil Boom with Flexible Skirt (유연한 스커트를 가진 오일붐의 운동응답해석)

  • 성홍근;조일형;최항순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.2
    • /
    • pp.156-162
    • /
    • 1995
  • A numerical method for a 2-D oil boom model considering the flexibility of skirt has been developed The neater is assumed rigid and the skirt is tensioned membrane having a point mass at its end The fluid motion is potential. The kinematic condition which demands the continuity of the displacement is imposed at the joint between the floater and the skirt. The dynamic condition for the point mass is imposed at the bottom end of the skirt. The numerical method is based on the Green's function method in the frame of linear potential theory. It finds it's solution simultaneously from the total system of three equations, integral equation, the equation of motion of the floater and the equilibrium equation of the deformation of the skirt. Integral equation is derived by applying the Green's theorem to radiation potential and Green's function. Proper descretization of those three equations leads to the system of a linear algebraic equation. Due to the flexibility of skirt the motion of floater can be diminished in some range of wave frequency and furthermore the mechanism of resonance of the oil boom can be changed. The motion responses of various oil booms have been compared varying the length of the skirt and the point mass. The numerical method has been validated indirectly from the good correspondence between the motion responses of the flexible skirt model and the rigid skirt model in low frequency limit.

  • PDF

The Effects of Knee Sleeve with a Stimulation of Golgi Tendon Organ on One Leg Standing and Proprioception (무릎 슬리브 착용과 골지 건 기관 자극이 한 발 서기 동작과 고유수용성 감각에 미치는 영향)

  • Jeong, BoRa;Chang, YoonHee;Kim, GyuSeok;Ryu, JeiCheong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.323-330
    • /
    • 2017
  • Knee sleeve has been used for prevention of sport injuries as well as rehabilitation. To investigate prevention of sport injuries of knee sleeve, it is important to evaluate balance associated with proprioception. The aim of this study was to evaluate the effects of a knee sleeve with a pad that stimulate to golgi tendon organ (GTO_PAD) on proprioception and balance ability. Five healthy males were participated for the study. They were asked to reenact target angle with Biodex and perform one leg standing with knee sleeve and knee sleeve with GTO_PAD. There was no significant difference in %Target angle, but the value of %Target angle was higher in subjects wearing knee sleeve with GTO_PAD than only knee sleeve, except for one subject. During one leg standing, time duration was increased in subjects wearing knee sleeve with GTO_PAD. The length of center of pressure in x-axis (COPx) and COP in y-axis (COPy) were decreased when wearing knee sleeve with GTO_PAD (COPx : $162.06{\pm}58.99mm$ in knee sleeve vs. $149.03{\pm}45.30mm$ in knee sleeve with GTO_PAD, COPy : $310.79{\pm}115.89mm$ in knee sleeve, $291.57{\pm}76.53mm$ in knee sleeve with GTO_PAD). There was significant differences in INI_transition, steady, and LAT_transition phase (all, p < 0.05). These findings support that wearing knee sleeve with GTO_PAD might enhance proprioception and balance.