• Title/Summary/Keyword: jet fire

검색결과 165건 처리시간 0.027초

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

와동과 상호작용하는 화염편에서의 오염물질 생성특성 (Pollutant Formation Characteristics in a Flamelet Interacting with a Vortex)

  • 오창보;이의주
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.9-16
    • /
    • 2010
  • Flame structure of diffusion flame interacting with a single vortex was investigated with direct numerical simulation (DNS). A well-known counterflow diffusion flame was used as an initial flat flame and single vortices were made by issuing a high-velocity jet abruptly in fuel- and air-side. The variations in the maximum concentration of major species (CO and $CO_2$) and NOx (NO and $NO_2$) with the stoichiometric scalar dissipation rate were investigated. Unsteady effects in the species concentration variation of the flame interacting with a vortex were identified by comparing with that of steady flame. $NO_2$ formation characteristics of the flame interacting with a vortex were well understood by investigating the $HO_2$ formation. To enhance the prediction performance in the fire simulation, current turbulent combustion modelings are needed to be modified by adopting the unsteady effects in the species concentrations of diffusion flame interacting with a vortex.

반밀폐공간에서 발생되는 차량용 수소연료탱크 폭발 실험 (An Experimental Study on the Explosion of Hydrogen Tank for Fuel-Cell Electric Vehicle in Semi-Closed Space)

  • 박진욱;유용호;김휘성
    • 자동차안전학회지
    • /
    • 제13권4호
    • /
    • pp.73-80
    • /
    • 2021
  • Recently, Korea has established a plan for the supply of hydrogen vehicles and is promoting the expansion of the supply. Risk factors for hydrogen vehicles are hydrogen leakage, jet fire, and explosion. Therefore Safety measures are necessary for this hazard. In addition, risks in semi-closed spaces such as tunnels, underground roads, and underground parking lots should be analyzed. In this study, an explosion experiment was conducted on a hydrogen tank used in a hydrogen vehicle to analyze the risk of a hydrogen vehicle explosion accident that may occur in a semi-closed space. As results, the effect on the structure and the human body was analyzed using the overpressure and impulse values for each distance generated during the explosion.

복합화력발전소 내 수소연료 적용 시 누출 사고에 대한 피해영향범위 분석: 지역별 환경 특성 영향에 기반하여 (Consequence Analysis on the Leakage Accident of Hydrogen Fuel in a Combined Cycle Power Plant: Based on the Effect of Regional Environmental Features)

  • 박희경;이민철
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.698-711
    • /
    • 2023
  • Consequence analysis using an ALOHA program is conducted to calculate the accidental impact ranges in the cases of hydrogen leakage, explosion, and jet fire in a hydrogen fueled combined cycle power plant. To evaluate the effect of weather conditions and topographic features on the damage range, ALOHA is executed for the power plants located in the inland and coastal regions. The damage range of hydrogen leaked in coastal areas is wider than that of inland areas in all risk factors. The obtained results are expected to be used when designing safety system and establishing safety plans.

추진시험설비의 사고피해영향분석 및 리스크 감소방안 (Consequence Analysis and Risk Reduction Methods for Propulsion Test Facility)

  • 신안태;변헌수
    • Korean Chemical Engineering Research
    • /
    • 제54권3호
    • /
    • pp.360-366
    • /
    • 2016
  • 한국형발사체 개발을 위한 추진시험설비가 구축되고 있으며, 일부 시험설비는 구축이 완료되어 추진기관시험을 실시하고 있다. 추진시험설비의 구성은 엔진 시험체 등의 시험을 실시하는 테스트 스탠드와 추진제로 사용되는 케로신(Jet A-1) 및 액체산소(LOX) 등을 저장하는 설비 등 다양한 서브시스템과 부품들이 연결되어 있다. 테스트 스탠드는 엔진개발모델이 장착되고 추진제가 혼합되어 실제 연소가 이루어지는 곳으로서 큰 에너지긴장도 상태에서 고압으로 작동되는 추진시험설비의 특성상 화재 폭발의 위험성이 존재한다. 본 논문에서는 추진시험설비의 사고피해영향분석 및 리스크 감소방안을 수립하기 위하여, 테스트 스텐드에서의 추진제 누설사고 시나리오를 가정하고, TNT당량모델 실험식을 적용하여 폭발과압에 대한 사고피해영향을 분석하였고, 추진시험설비의 안전성 확보를 위한 리스크 감소방안에 대하여 기술적, 제도적, 관리적 안전대책에 대하여 제시하였다.

정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구 (A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment)

  • 김희진;장경민;김수현;김기범;정은상
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.

진동대 시험을 이용한 유기질토가 협재된 모래지반의 내진 안정성 평가 (Seismic Stability Evaluation of Sand Ground with Organic Soil by Using Shaking Table Test)

  • 정용진;백영철;이동혁
    • 한국지반환경공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.13-20
    • /
    • 2023
  • 강릉지역은 유기질토가 생성되기 적합한 환경을 지닌 지역으로 유기질토 상부와 하부에 퇴적 모래층이 분포되어 있는 충적층 지반이 존재한다. 본 연구는 모래층 사이에 유기질토 및 점토가 협재된 지반 상부에 조성된 강릉지역을 통과하는 철도노반의 내진 안전성을 평가하기 위하여 상사율을 고려한 철도노반 및 지반 모형을 제작하여 진동대 시험을 실시하고 유효응력 해석 결과값을 비교하여 내진 안정성을 평가하였다. 적용된 지진파는 인공지진파, 경주지진파, Borah 지진파, Nahanni 지진파, Tabas 지진파를 적용하였으며 상부 모래층의 최대 응답가속도는 0.239g(인공지진파), 과잉간극수압비는 0.509(Borah파)가 발생하는 것으로 분석되었다. 신설노반의 하부지반에 적용된 jet grouting에 의한 지반보강 효과로 인해 신설 노반의 발생변위는 기존노반에 비해 최소 33.7%에서 최대 56.7% 감소한 것으로 나타났다. 진동대 시험결과는 Flac 프로그램의 Finn 모델을 적용한 유효응력해석으로 검증하였으며, 진동대 시험값과 유사한 경향을 나타내었다.

인접 건물 간 최소 안전거리를 고려한 군부대 내 수소충전소 위치선정 연구 (A Study on the Selection of Hydrogen Refueling Station Locations within Military Bases Considering Minimum Safe Distances between Adjacent Buildings)

  • 김동연;권혁진
    • 인터넷정보학회논문지
    • /
    • 제24권6호
    • /
    • pp.171-180
    • /
    • 2023
  • 수소에너지 기술은 4차 산업 시대에서 주목받는 중요한 분야로 수소와 산소를 활용하여 전기 에너지를 생성하는 기술이다. 이 기술을 군사 차량에 적용할 경우, 온실가스 감소, 무소음, 저 진동 및 낮은 발열량의 효과로서 군사적으로 전략적 이점을 얻을 수 있어 다국에서 수소 군사 차량을 위한 연구 중이다. 우리나라 또한 미래 군사 차량에 수소를 적용하고 소형화 및 AI를 통한 스마트화 시키는 미래전을 대비한 전략인 Army Tiger4.0 계획을 수립하였다. 또한 국방부는 군용 수소충전소 설치에 따라 군 내 수소차 보급에도 탄력이 붙을 것으로 예상하여 환경부와의 협력으로 군용 수소충전소를 전국적으로 확충하기 위한 계획을 수립하였다. 하지만 수소는 화재와 폭발 위험물질로 안전한 충전소 구축과 효과적인 관리를 위한 체계적인 제도가 필요하다. 현재 군에서는 지정한 수소충전소 시설의 분류와 설치 조건을 군 시설 설계지침서를 통해 확인하였다. 그 결과, 충전소는 주유 시설로 분류되며 인접 건물과의 최소 안전거리를 2m 이상으로 이격시키는 것만 명시되어 있을 뿐 안전거리에 대한 그 외의 내용은 명시되지 않았다. 폭발의 규모가 큰 수소의 특성을 고려하여 과학적 기법을 통해 사고 피해 범위를 정량적으로 파악하고 피해 거리 밖으로 최소 안전거리를 제시하였다.

도로터널에서 수소차 사고시나리오 개발 및 위험거리에 대한 분석 연구 (Development of FCEV accident scenario and analysis study on dangerous distance in road tunnel)

  • 이후영;류지오
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.659-677
    • /
    • 2022
  • 수소는 차세대 에너지원으로 부각되고 있으며, 수소차(FCEV)개발 및 보급이 급속도로 이루어질 것으로 예상된다. 이에 수소차 사고에 대응하기 위한 대책이 요구되고 있으며, 수소차의 안전성에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 기존 실험 및 연구자료에 대한 분석을 통해 도로터널에서 수소차 안전성 평가를 위하여 국내 실정에 맞는 수소차 사고시나리오를 개발하였으며, 수소차 사고시나리오의 사고결과에 대한 위험거리를 분석·제시하였다. 수소차 사고시나리오에 따른 사고결과는 경미한 사고, 일반화재, 제트화염, 폭발로 구분되며, 각각의 발생확률을 93.06%, 1.83%, 2.25%, 2.31%로 예측된다. 표준단면(72 m2)의 도로터널에서 국내에서 시판되는 수소차량의 수소탱크제원을 적용하는 경우, 사고결과에 따른 위험 거리는 폭발의 경우 약 17.6 m (폭발압력 16.5 kPa기준), 제트화염은 약 6 m, 파이어볼 형성에 따른 위험거리는 최대 35 m로 분석되었다.

BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책 (Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant)

  • 우인성;이중희;이인복;천영우;박희철;황성민;김태옥
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.22-28
    • /
    • 2012
  • BPA 공장의 메탄올 분리공정에서 HAZOP 평가를 실시하고, 사고 시나리오로부터 화재 및 폭발 사고의 피해범위를 예측하였다. 그 결과, 화재사고의 피해범위는 50 mm 직경의 안전밸브 토출배관 파열에 의한 제트화재에서는 20 m이었고, 설비가 전파되어 플래쉬화재가 발생되는 경우에는 267 m이었다. 또한 개방공간 증기운 폭발사고의 피해범위는 토출배관 파열에서는 22 m이었고, 설비 전파인 경우에는 542 m이었다. 그리고 최악의 누출 시나리오에 대한 안전대책으로는 메탄올 분리컬럼 내부의 이상압력 상승을 감지할 수 있는 압력계를 2 out of 3 voting으로 설비 상부에 설치하여 주공급라인 상에 설치된 컨트롤밸브와 긴급차단밸브를 동시에 차단할 수 있도록 하여야 한다.