• Title/Summary/Keyword: jaw angle

Search Result 123, Processing Time 0.021 seconds

A Comparison of pre and post-surgical characteristics in skeletal Class III malocclusion patients using counterpart analysis (구조적 대응체 분석법에 의한 골격성 II급 부정교합 환자의 악교정 수술전후의 비교)

  • Sohn, Byung-Wha;Kyung, Seung-Hyun;Kim, Beom-soo
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.93-107
    • /
    • 2004
  • Enlow's counterpart analysis explains the complex with anatomic and developmental characteristics where craniofacial aspect of Individuals has been developed. Counterpart analysis does not compare individual measurement with the normal value from the average of majority but analyzes by comparison of values that each individual has. In this study we examined surgical changes in skeletal Class III malocclusion patients(male 40, female 40) and compared them with normal occlusion patients using counterpart analysis. The results indicated that : 1. Skeletal anterior-posterior discrepancy was relieved by shortening of the ramus width(B3). 2. The ramus alignment(R3, R4) was displaced posteriorly and the occlusal plane angle(R5) was rotated clockwise. 3. Skeletal Class III pattern was relieved in the post-operative group, but differences in the level of the cranium(R1, R2) was remaining compared to the normal occlusion patients. 4. In the comparison of surgery methods, the two-jaw surgery group presented changes In the maxillary length(A4), ramus alignment(R3, R4) and occlusal plane angle(R5) compared to the one-jaw surgery group, but the differences were not significant. In the past study about Korean skeletal Class m patients, the skeletal characteristics are upward backward rotation of the cranial base, posterior displacement of the maxilla, forward inclination of the ramus and lengthening of the mandibular body, but in this study, skeletal Class m pattern was relieved by shortening of the ramus width and maxillary advancement by orthognathic surgery, because orthognathic surgery is usually performed on limited areas in the maxilla and the mandible.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

The rehabilitation of an edentulous maxilla with an implant-supported fixed prosthesis using a zirconia framework: A case report (상악 완전무치악에서 지르코니아 framework을 이용한 임플란트 지지형 고정성 보철 수복 증례)

  • Byun, Jae-Joon;Jang, Eun-Sun;Kong, Dae-Ryong;Song, Joo-Hun;Lee, Gyeong-Je
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.342-348
    • /
    • 2020
  • Anatomical changes in the facial and alveolar bones occur after multiple teeth are extracted. In the maxilla, the alveolar bone is absorbed in the direction and inclination of the root, and the remaining alveolar bone becomes shorter, reducing the diameter of the arch. In addition, as the nasolabial angle increases, the support of the lips and the aesthetics of the face are lost. This case reports a functional and aesthetically satisfactory results of full mouth rehabilitation with the implant-supported fixed prosthesis using a zirconia framework.

Anatomical Measurement of the Masseter Muscle and Surface Mapping of the Maximal Thickness Point Using Computed Tomography Analysis (전산화단층촬영 영상분석을 이용한 교근의 해부학적 계측 및 최대 두께점 피부 표지화)

  • Suh, Hyeun-Woo;Kim, Hyo-Seong;Ha, Ki-Young;Kim, Boo-Yeong;Pae, Nam-Seok;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • Purpose: Masseter muscle is an important muscle of mastication. Because it has a great influence on the shape of low facial contour, patients who have masseteric hypertrophy show square-shaped jaw appearance. As aesthetic procedures for the reduction of the masseter muscle volume, radiofrequency ablation or botulinum toxin injection is at the center of attention. Authors studied the anatomical measurement of the thickness and width of masseter muscle and the surface mapping of the maximal thickness point using computed tomography (CT) scan to identify the useful guide for the injection of botulinum toxin in masseteric hypertrophy patients. Methods: We analyzed 2 mm-thickness OMU (ostiomeatal unit) CT of 112 normal people (224 masseter muscles) taken from June 2009 to May 2010. First, we measured the thickness, width and depth of the masseter muscle from the skin surface and analysed each by side, sex and age, respectively. The distribution of the thickness of the muscle and the correlation of thickness and width of the muscle were studied also. Second, we underwent surface mapping of the maximal thickness point using CT analysis by means of checking the vertical and horizontal distance from the angle of the mandible. Results: The average thickness and width of the masseter muscle was 17.73 mm and 40.78 mm in the male patients and were 14.33 mm and 37.42 mm in the female patients. Statistically, both figures of the male patients were larger than those of the female patients. However, the depth of the muscle from the skin surface in female patients (7.37 mm) was larger than that of the male patients (6.15 mm). There were no statistical difference in side or age. The width and thickness of the masseter muscle were in the positive correlation. The location of maximal thickness point of the masseter muscle was 27.77 mm vertically and 27.68 mm horizontally in the male patients, and 25.19 mm vertically and 25.42 mm horizontally in the female patients from the angle of mandible. Conclusion: We were able to present statistical evidence of the diagnosis and treatment of the masseteric hypertrophy regarding the anatomical measurements such as the thickness and width. And the maximal thickness point of the masseter muscle may be a useful guide for the clinical procedures of botulinum toxin injection.

Characteristics of dose distribution for virtual wedge (가변형 쐐기필터의 선량분포에 관한 특성)

  • 김부길;김진기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • We was investigate the dosimetric characteristics of the virtual wedge and it compared to the conventional fixed wedge. Also we was evaluate the quality factor of the experimental multi-channel dosimetry system for virtual wedge. Recently virtual wedge technique and wedge fraction methods are available through the computer controlled asymmetric collimator or the independent jaw in medical linear accelerator for radiation therapy. The dosimetric characteristics are interpreted by radiation field analyzer RFA-7 system and PTW-UNIDOS system. Experimental multi-channel dosimetry system for virtual wedge was consists of the electrometer, the solid detector and array phantom. The solid detectors were constructed using commercially diodes for the assessment of quality assurance in radiotherapy. And it was used for the point dose measuring and field size scanning. The semiconductor detector and ion chamber were positioned at a dmax, 5 cm, 10 cm, 20 cm depth and its specific ratio was determined using a scanning data. Wedge angles in fixed and virtual type are compared with measurements in water phantom and it is shown that the wedge angle 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$were agree within 1$^{\circ}$ degree in 6, 10 MV photon beams. In PDD and beam flatness, experimental multi-channel disimetry system was capable of reproduceing the measured values usually to within $\pm$2.1% the statistical uncertainties of the data. It was used to describe dosimetric characteristics of virtual wedge in clinical photon beams. Also we was evaluate optimal use of the virtual wedge and improve the quality factor of the experimental multi-channel dosimetry system for virtual wedge.

  • PDF

The Effect of The Forward Head Posture on The Maximum Mouth Opening of The Temporomandibular Joint, The Muscle Activity and The Asymmetry Rate of The Temporalis and Masseter (머리전방자세가 턱관절의 최대 개구량과 관자근 및 깨물근의 근활성도와 비대칭률에 미치는 영향)

  • Yang, Yong-Pil;Seo, Dong-yel
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.291-296
    • /
    • 2021
  • This study examined the effects of the forward head posture on the maximum mouth opening of the jaw joint and the muscle activity and asymmetry of the temporalis and masseter. The craniovertebral angle was measured in 50 subjects (23.10±2.73 years) who met the selection requirements of the study. The maximum mouth opening, muscle activity, and muscle asymmetry were measured by reducing 0%, 10%, and 20%. As the craniovertebral angle decreased, the maximum mouth opening decreased (p<.001), the muscle activity of the right and left temporalis decreased (p<.001), and the muscle activity of the left temporalis also decreased. (p<.01). The asymmetry rate of the added muscles of the left and right temporalis, left and right temporalis, and masseter increased according to the change in condition (p<.01). The results of this study are expected to help establish a treatment strategy and comprehensive diagnosis for the temporomandibular joint and present a theoretical basis of manual therapy and therapeutic exercises used for the treatment of TMD.

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.

Logic for the use of stable structural superimposition method and introduction of its application (안정골구조물 중첩법(stable structural superimposition method)을 사용해야 하는 합리적 근거 및 그 중첩방법의 소개)

  • Chun, Youn-Sic;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.669-682
    • /
    • 1997
  • [$Bj\ddot{o}rk$] and Skieller concluded after following facial growth patterns using implants in upper and lower jaw bones that stable structures, which are not influenced by the growth do exist and so these must be the reference landmarks in the process of superimposition. In spite of such facts, for the last 40 years since the discovery of stable structures, most orthodontists have preferred best fit superimposition method to structural method. Cases such as Angle's Class II division 2 malocclusion that show characteristic forward and upward growth or one under long period of post-treatment observation demonstrate that distinct differences exist between the two methods of superimposition. Today, ethical concerns prohibit further growth studies that use implants, md so there is no choice but to use stable structural superimposition method based on $Bj\ddot{o}rk's$ data. Thus, to encourage clinical use of stable structural superimposition method, logic for the use of stable structural superimposition method will be demonstrated, and its technical methods of application will be introduced step by step.

  • PDF

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.