• 제목/요약/키워드: j factor

검색결과 2,578건 처리시간 0.031초

Quadratic strip theory for high-order dynamic behavior of a large container ship with 3D flow effects

  • Heo, Kyeong-uk;Koo, Weoncheol;Park, In-Kyu;Ryue, Jungsoo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권2호
    • /
    • pp.127-136
    • /
    • 2016
  • Springing is the resonance phenomenon of a ship hull girder with incoming waves having the same natural frequency of the ship. In this study, a simple and reliable calculation method was developed based on quadratic strip theory using the Timoshenko beam approach as an elastic hull girder. Second-order hydrodynamic forces and Froude-Krylov forces were applied as the external force. To improve the accuracy of the strip method, the variation in the added mass along the ship hull longitudinal direction, so called tip-effect, was considered. The J-factor was also employed to compensate for the effect of three-dimensional fluid motion on the two-node vibration of the ship. Using the developed method, the first- and second-order vertical bending moments of the Flokstra ship were compared. A comparative study was also carried out for a uniform barge ship and a 10,000 TEU container ship with the respective methods including the J-factor and tip-effect.

EFFICACY EVALUATION OF THE WHITENING COSMETICS USING MELANOGENESIS INHIBITION ASSAY COSMETICS IN B-16 MELANOMA CELL

  • S. J. Yang;S. J. Jang;Park, S. S.;J. Y. Jang;K. H. Son;Lee, J. P.;Lee, K. S.;M. Y. Heo;Kim, Y. O.
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.544-544
    • /
    • 2003
  • We investigated the inhibitory effect of whitening materials with growth factor or alone on melanomas derived from Human (B-16) and mouse (SK-MEL-31) using melanin content. Melanin content was determined by the absorbance value at 470nm per cells. we used the growth factors known as activators of Adenylate cyclase, Protein kinase C and tyrosine kinase pathway separately. In addition, we compared the action of UV-induced with non-biological growth factor with whitening materials in melanomas derived from Human and mouse. The results showed that the aspect of inhibitory effect of whitening materials on B16 and SK-MEL-31 was not different. And, the action of each growth factor involved in the differentiation and proliferation of melanoma on the inhibition of melanogenesis in B-16 and SK-MEL-31 using whitening agents showed no difference. Also, The action of UV -induced and non-biological growth factors didn't exhibit different pattern on the effect of whitening agent in B-16 and SK-MEL-31.

  • PDF

딤플형 판형 열교환기의 유동 및 전열특성에 대한 수치해석 (A Numerical Simulation of Flow and Heat Transfer in a Dimple-type Plate Heat Exchanger)

  • 안혁진;이상혁;허남건;박형준;유해성
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.149-155
    • /
    • 2010
  • In the present study, the characteristics on the internal flow and heat transfer of the dimple-type plate heat exchanger were numerically investigated. For the numerical analysis, the conjugate heat transfer analysis between hot fluid-separating plate-cold fluid was performed using the periodic boundary condition at the center area of the plate and appropriate inlet and outlet conditions for the two streams. The numerical results were validated by the comparison with the experimental data. From these results, the correlations of the Colburn j-factor for the heat transfer and the Fanning f-factor for the flow friction were obtained. The present results could be applicable for the optimal design of dimple-type plate heat exchanger.

자동차용 파워트레인 마운팅 시스템의 최적설계 (Optimum Design of Vehicle Powertrain Mounting System)

  • 김진훈;이수종;이우현;김정렬
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2010
  • Technology of vehicle industry has been developing and it is required a better vehicle performance than before. Therefore, the consumers are asking not only an economic efficiency, functionality, polished design, ride comfort and silence but also a driving stability. The ride comfort, silence and driving stability are influenced by the size of vehicle and various facilities. But the principal factor is a room noise and vibration sensed by a driver and passenger. Thus, the NVH of vehicle has been raised and used as a principal factor for evaluation of vehicle performance. The primary objective of this study is an optimized design of powertrain mounting system. To optimized design was applied MSC.Nastran optimization modules. Results of dynamic analysis for powertrain mounting system was investigated. By theses results, design variables was applied 12 dynamic spring constant. And the weighting factor according to translational displacement and rotational displacement applied 3 cases. The objective function was applied to minimize displacement of powertrain. And the design variable constraint was imposed dynamic spring constant ratio. The constraint of design variable for objective function was imposed bounce displacement for powertrain.

동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구 (Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump)

  • 권영철
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1337-1342
    • /
    • 2007
  • 본 연구에서는 동시 냉난방 히트펌프용 열교환기의 성능평가 및 설계해석 기술의 확보를 위해 난방운전 온도조건에서 6종의 루버핀-관 열교환기의 공기측 열전달특성 및 마찰특성을 실험을 통하여 조사하였다. 실험을 위해 공기엔탈피방식의 칼로리미터와 항온수조를 이용하였다. 전열량의 증가는 핀피치보다 열수에 의해 더 크게 나타났고, 핀피치가 작을수록 열전달계수는 더 높았다. 또한 핀피치가 작을수록 열수증가에 의한 열전달계수의 증가폭이 커졌다. 핀피치와 열수변화에 대한 j-계수와 f-계수는 레이놀즈 수가 증가할수록 감소하였고, 레이놀즈 수 400부근의 영역에서 역전현상이 존재하였다.

  • PDF

경계요소법을 이용한 계면균열의 응력특이성에 관한 고찰 (Study on the Stress Singularity of Interface Crack by using Boundary Element Method)

  • 조종두;곽시영
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.197-204
    • /
    • 1999
  • The boundary element method was used for studying singularities of an interface crack with contact zones. The iterative procedure is applied to estimate the contact zone size. Because the contact zone size was extremely small in a tension field, a large number of Gaussian points were used for numerical integration of the Kernels. Stress extrapolation method and J-integral were used ofr determining stress intensity factors. When the interface crack was assumed to have opened tips, oscillatory singularities appear near the tips of the interface crack. But the interface crack with contact zone which Comninou suggested had no oscillatory behavior. The contact zone size under shear loading was much larger than that under tensile. The stress intensity factors computed by stress extrapolation method were close to those of Comninou's solution. And the stress intensity factor evaluated by J-integral was similar to that by stress extrapolation method.

  • PDF

과단면적 계수를 고려한 철심 변류기 설계 방법 (An Iron-cored CT Design Considering Overdimensioning Factor)

  • 이주훈;강상희;이승재;강용철;배주천;안준기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.834-836
    • /
    • 1998
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current. However, the possibility of CT saturation still remains, because the fault current may have substantial amounts of ac and/or de components. This paper presents a iron-cored CT design method to prevent CT saturation. The proposed method employs the overdimensioning factor $(K_{ta})$ considering dc components contained as well as symmetrical ac components in the fault current.

  • PDF

Experimental and numerical analysis of fatigue behaviour for tubular K-joints

  • Shao, Yong-Bo;Cao, Zhen-Bin
    • Structural Engineering and Mechanics
    • /
    • 제19권6호
    • /
    • pp.639-652
    • /
    • 2005
  • In this paper, a full-scale K-joint specimen was tested to failure under cyclic combined axial and in-plane bending loads. In the fatigue test, the crack developments were monitored step by step using the alternating current potential drop (ACPD) technique. Using Paris' law, stress intensity factor, which is a fracture parameter to be frequently used by many designers to predict the integrity and residual life of tubular joints, can be obtained from experimental test results of the crack growth rate. Furthermore, a scheme of automatic mesh generation for a cracked K-joint is introduced, and numerical analysis of stress intensity factor for the K-joint specimen has then been carried out. In the finite element analysis, J-integral method is used to estimate the stress intensity factors along the crack front. The numerical stress intensity factor results have been validated through comparing them with the experimental results. The comparison shows that the proposed numerical model can produce reasonably accurate stress intensity factor values. The effects of different crack shapes on the stress intensity factors have also been investigated, and it has been found that semi-ellipse is suitable and accurate to be adopted in numerical analysis for the stress intensity factor. Therefore, the proposed model in this paper is reliable to be used for estimating the stress intensity factor values of cracked tubular K-joints for design purposes.