• Title/Summary/Keyword: isothermal

Search Result 1,475, Processing Time 0.028 seconds

Hot Stamping Simulations and Experiments for CTBA Tubular Beams (CTBA Tubular Beam의 열간 성형해석 및 실험)

  • Suh, C.H.;Kim, W.S.;Sung, J.H.;Park, J.K.;Kim, Y.S.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • For an accurate analysis of hot stamping, a coupled simulation with different aspects of the process(i.e. mechanical, thermal, and phase transformation) is needed. However, coupled simulations are time consuming and costly. Therefore, the current study proposes a simplified method focused on the forming for the hot stamping simulation of a coupled torsion beam axle (CTBA) tubular beam. In this simplified method, non-isothermal conditions were assumed and only conduction was considered, since it represents the majority of the heat transfer during hot stamping. In addition, temperature and strain rate effects were also included. Moreover, an isothermal simulation was conducted and compared with a non-isothermal simulation. Finally, the simulations were verified by experiments. In conclusion, the proposed method is shown to be effective for the development of tube-type parts, and it effectively predicts the deformation of the tubular beam during hot stamping.

Finite Element Analysis of warm Circular Cup Deep Drawing Process of AZ31 Sheet (AZ31 판재의 온간 원형컵 딥드로잉 공정의 유한요소 해석)

  • Lee, M.H.;Kim, H.Y.;Kim, H.K.;Oh, S.I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.230-233
    • /
    • 2007
  • Due to their low density, high specific strength and electromagnetic interference shielding, magnesium alloy sheets are used increasingly more often in automotive, aerospace, and electronics industries. However, magnesium ally sheets should be usually formed at elevated temperature because of their poor formability at room temperature. For the use of magnesium alloy sheets for an industrial, their mechanical properties at elevated temperature and appropriate forming process conditions have to be developed. In this study, the warm deep drawing process of AZ31 sheets is studied numerically by non-isothermal simulation. The difference between the isothermal simulation results and the non-isothermal simulation results and the progress of warm forming are discussed.

  • PDF

Isothermal Oxidation Behaviour of Domestic Superalloys at Elevated Temperature (국산 Superalloy의 고온 산화 거동)

  • 강은철;전영건;김길식
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.3
    • /
    • pp.151-161
    • /
    • 1991
  • The isothermal oxidation behaviour of commercial superalloys produced in Korea was investigated by using Cahn-2000 microbalance in air at $1000^{\circ}C$ and $1100^{\circ}C$. The effect of alloying elements on the isothermal oxidation was studied by examination of the oxide structures, their morphologies, and EDS linescanning and mapping of cross-section of oxidized specimens. Generally, external Cr2O3 films were formed on all alloy surface, but were not pure, The effect on the oxidation behaviour of refractory elements such as Nb, Mo in Inconel 718 was considered to be deleterious, and the formation of internal Al oxide in Inconel 601 was beneficial.

  • PDF

A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder (공압실린더의 누설유량 계측방법에 관한 연구)

  • Jang J.S.;Ji S.W.;Jeong J.H.;Kang B.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

Loop-mediated Isothermal Amplification Assay to Rapidly Detect Wheat Streak Mosaic Virus in Quarantined Plants

  • Lee, Siwon;Kim, Jin-Ho;Choi, Ji-Young;Jang, Won-Cheoul
    • The Plant Pathology Journal
    • /
    • v.31 no.4
    • /
    • pp.438-440
    • /
    • 2015
  • We developed a loop-mediated isothermal amplification (LAMP) method to rapidly diagnose Wheat streak mosaic virus (WSMV) during quarantine inspections of imported wheat, corn, oats, and millet. The LAMP method was developed as a plant quarantine inspection method for the first time, and its simplicity, quickness, specificity and sensitivity were verified compared to current reverse transcription-polymerase chain reaction (RT-PCR) and nested PCR quarantine methods. We were able to quickly screen for WSMV at quarantine sites with many test samples; thus, this method is expected to contribute to plant quarantine inspections.

Dielectric Changes During the Curing of Epoxy Resin Based on the Diglcidyl Ether of Bisphenol A (DGEBA) with Diamine

  • 김홍경;차국헌
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.11
    • /
    • pp.1329-1334
    • /
    • 1999
  • The curing characteristics of diglycidyl ether of bisphenol A (DGEBA) with diaminodiphenylmethane (DDM) as a curing agent were studied using differential scanning calorimetry (DSC), rheometrics mechanical spectrometry (RMS), and dielectric analysis (DEA). The isothermal curing kinetics measured by DSC were well represented with the generalized auto-catalytic reaction model. With the temperature sweep, the inverse relationship between complex viscosity measured by RMS and ionic conductivity obtained from DEA was established indicating that the mobility of free ions represented by the ionic conductivity in DEA measurement and the chain segment motion as revealed by the complex viscosity measured from RMS are equivalent. From isothermal curing measurements at several different temperatures, the ionic conductivity contribution was shown to be dominant in the dielectric loss factor at the early stage of cure. The contribution of the dipole relaxation in dielectric loss factor became larger as the curing further proceeded. The critical degrees of cure, at which the dipolar contribution in the dielectric loss factor starts to appear, increases as isothermal curing temperature is increased. The dielectric relaxation time at the same degree of cure was shorter for a sample cured at higher curing temperature.

Development of Diagnostic Technology of Xylella fastidiosa Using Loop-Mediated Isothermal Amplification and PCR Methods

  • Kim, Suyoung;Park, Yujin;Kim, Gidon
    • Research in Plant Disease
    • /
    • v.27 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • Xylella fastidiosa is the most damaging pathogen in many parts of the world. To increase diagnostic capability of X. fastidiosa in the field, the loop-mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR) assay were developed to mqsA gene of citrate-synthase (XF 1535) X. fastidiosa and evaluated for specificity and sensitivity. Both assays were more robust than current published tests for detection of X. fastidiosa when screened against 16 isolates representing the four major subgroups of the bacterium from a range of host species. No cross reaction with DNA from healthy hosts or other species of bacteria has been observed. The LAMP and PCR assays could detect 10-4 pmol and 100 copies of the gene, respectively. Hydroxynaphthol blue was evaluated as an endpoint detection method for LAMP. There was a significant color shift that signaled the existence of the bacterium when at least 100 copies of the target template were present.

Experiments of Turbulent Thermal Mixing Phenomena Using Parallel Non-Isothermal Water Jets

  • Kim, Y.K.;Kim, J.M.;Lee, Y.B.;J.S. Hwang;H.Y. Nam
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.36-41
    • /
    • 1996
  • Turbulent thermal mixing experiments by the injection of two parallel non-isothermal water jets have been performed. The turbulent velocities and fluctuations under the isothermal conditions have been measured using LDV system. The velocity vectors have been plotted in two dimensions from the data measured at 29$\times$16 points. The thermal mixing experiments also have been conducted, where we used 45 K-type thermocouples with a sheath diameter of 0.020" which were fixed with 5 mm distance in a line at a measured height. The measured heights were 5, 10, 20, 30, 40 cm from the upper end of rectangular nozzles. We measured the turbulent temperatures under the various flow velocity conditions with 12$^{\circ}C$ $\leq$ $\Delta$T $\leq$4$0^{\circ}C$. The sampling frequency and sampling time were about 420 Hz and 10 seconds, respectively. The measured results of equal velocity parallel jets were analyzed axially and radially to obtain the variation of temperature fluctuation.tion.

  • PDF

The Characteristics of Isothermal Conduction Calorimetry and Specific Heat in Coal Gasification Slag (석탄 가스화 용융 슬래그의 비열 및 미소수화열 특성)

  • Han, Jun-Hui;Hu, Yun-Yao;Lim, Gun-Su;Kim, Su-Hoo;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.182-183
    • /
    • 2021
  • In this study, This is the result of thermal characteristics analysis to suggest an efficient method of using coal gasification slag(CGS) of byproduct from integrated gasification combined cycle(IGCC). In Specific Heat characteristics, CGS and CS showed similar values. Isothermal Conduction Calorimetry showed that the hydration reaction of cement was retarded when CGS was used. Therefore, it is expected that CGS will be used as an efficient alternative to reducing the hydration heat of mass concrete as a functional aggregate combination.

  • PDF

Development of Loop-mediated Isothermal Amplification (LAMP) for Detection of Vibrio alginolyticus (Loop-mediated isothermal amplification (LAMP)법을 이용한 Vibrio alginolyticus의 신속 진단법 개발)

  • Hong, Seung-hyun;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.903-909
    • /
    • 2015
  • Loop-mediated isothermal amplification (LAMP), a PCR-based diagnostic method, is based on autocycling strand displacement DNA synthesis in the presence of exonuclease-negative Bst DNA polymerase under isothermal conditions. With the help of four specific primers that recognize six different sequences of a target DNA, LAMP has high specificity in pathogenic identification in a short time. Hence, in the present study, LAMP is used as a diagnostic tool in the identification of the most dreadful aquatic pathogenic species, Vibrio alginolyticus, and to develop species-specific LAMP primers and optimization of LAMP reaction conditions such as annealing temperature, elongation time, and other PCR chemical concentrations, including MgSO4, dNTPs, Betaine, and Bst polymerase. The optimized LAMP primers were also checked for specificity with other Vibrio species, which showed that the designed primers were very specific to V. alginolyticus After the first introduction of a species name like this one, the first part (“Vibrio” in this case) should be abbreviated to only the first letter.only. These are usually the most harmful pathogens of the Vibrio species that appear in shrimp and crabs. The results also revealed that the LAMP assay could be 10-fold more sensitive than conventional PCR in detecting V. alginolyticus. This could be the first report on using a rapid and highly sensitive technique, the LAMP assay, in the effective diagnosis of the pathogenic bacteria V. alginolyticus, which could help in the early detection of diseases, particularly in aquaculture.