• 제목/요약/키워드: isothermal

검색결과 1,475건 처리시간 0.03초

비등온 난류 제트의 이상유동에 대한 수치모델 (Numerical Modeling of Two-Phase Non-Isothermal Turbulent Jet)

  • 황득리엔;김명관;권오붕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.783-788
    • /
    • 2001
  • Choosing the most suitable mathematical model and relating this to turbulent tangential tensions model are very important in the investigations of turbulent two-phase flow. This paper considers two-fluid scheme. According to it, two phases have their own densities, velocities, and temperatures at any spatial point and at any moment. The equations of motion and heat transfer for each phase are linked with the forces of interaction between two phases. These forces are considered as predominant for the flow. As a closure in the system of motion equations, one modification of $K - {\epsilon}$ turbulent model is worked out. The modification uses two equations for turbulent kinetic energy of the phases and one - for the turbulent energy loss of main phase. This model can be set as a $K_g - K_p -{\epsilon}$ model. The modified model has been tested for both a two-phase non-isothermal flat jet and axially symmetrical jet. The numerical results are compared with the reference data revealing a good agreement between them.

  • PDF

수직으로 엇갈린 등온평판에서의 혼합대류 열전도 (Mixed Convection Heat Transfer from Vertically Misaligned Isothermal plates)

  • 권순석;김상영;박순업
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.52-61
    • /
    • 1992
  • The steady laminar mixed convection from vertically misaligned, isothermal plastes has been studied by numerical procedure. The governing equations are solved by the finite difference method using successive using successive over relaxation scheme at Re=100-800, $Gr=10^3-10^6$, Pr=0.71 and dimensionless plate spacings b/L=0.1-1.0. The plume interaction caused by the thermal interference of twoplates is observed. As Reynolds numbers increase, the optimum plate spacings are moved to narrow spacings at the same Grashof number and as Grashof numbers increase, to wide spacings at the same Reynolds number.

  • PDF

난류선회 등온 및 분무연소 유동에 대한 수치해석 (Numerical Study of Turbulent Swirling Isothermal and Spray-Combusting Flows)

  • 김성구;안국영;김용모;이창식
    • 한국자동차공학회논문집
    • /
    • 제4권5호
    • /
    • pp.130-141
    • /
    • 1996
  • Numerical study of a confined, swirling, isothermal and spray-combusting flows has been presented. The pressure-velocity coupling in the Eulerian gas-phase equation is handled by the improved PISO algorithm. The droplet dispersion by turbulence is introduced by a Stochastic Separated Flow(SSF) model. The k-$\varepsilon$ turbulence model and the eddy dissipation model are employed to account for turbulence-combustion interaction. The detailed comparison with experimental data has been made for the isothermal jet swirling flows and the nearly monodisperse spray-combusting flow in the swirl combustor.

  • PDF

층간분리 방지를 위한 건식 등온 신선 패스 설계 (Isothermal Pass Schedule to Prevent Delamination in the Dry Wire Drawing Process)

  • 고대철;이상곤;김민안;김병민
    • 한국정밀공학회지
    • /
    • 제24권1호
    • /
    • pp.57-63
    • /
    • 2007
  • Wire drawing process of the high carbon steel with a high speed is usually conducted at room temperature using a number of passes or reductions through consequently located dies. In the multi-pass drawing process, temperature rise in each pass affects the mechanical properties of the final product such as bending, torsion, and tensile property, etc. This temperature rise during the deformation promotes the occurrence of delamination, and deteriorates the torsion property and durability of wire. This study investigates the occurrence of delamination in the wire through the torsion test and the evaluation of wire temperature. The excessive wire temperature leads to the occurrence of the delamination. Based on the calculation of the wire temperature, a new pass schedule, which can prevent the delamination due to the excessive wire temperature rise, is designed through the isothermal pass schedule.

Loop-mediated isothermal amplification assay for the detection of Salmonella spp. in pig feces

  • Kim, Yong Kwan;Kim, Ha-Young;Jeon, Albert Byungyun;Lee, Myoung-Heon;Bae, You-Chan;Byun, Jae-Won
    • 대한수의학회지
    • /
    • 제54권2호
    • /
    • pp.113-115
    • /
    • 2014
  • Salmonella are causative agents of gastroenteritis and systemic disease in animals. The invA gene was selected as a target sequence of loop-mediated isothermal amplification (LAMP) assay for diagnosis of Salmonella infection. The detection limits for broth dilution, spiked feces and enrichment were $10^4$, $10^5$ and $10^2$ CFUs/mL, respectively. The LAMP assay developed in the present study may be a reliable method for detection of Salmonella spp. in pig feces.

Non-isothermal pyrolysis of cashew shell cake-bituminous coal blends

  • Park, Yoon Hwa;Park, Ho Young;Kim, Hyun Hee;Park, Sang Bin
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.121-128
    • /
    • 2018
  • This paper describes the non-isothermal pyrolysis of cashew shell cake (CSC) - bituminous coal blends. The blends exhibit two distinct stages in the thermogravimetric curves, which the first stage stems from CSC and the second one from the superposition of CSC and coal pyrolysis. The pyrolysis behavior of the blend was linearly proportional to the blending ratios. The overall behavior of the blends was evaluated in terms of the maximum rate of weight loss, characteristic temperatures, char yields, and the calculated and experimental thermogravimetric curves. The activation energies ranged up to 49 kJ/mol for the blends were obtained and used to evaluate the interaction in the blends. The present thermogravimetric study shows that there is no significant interaction between CSC and coal in the blends, and it was supported by the characteristic values which are linearly proportional to the weight percentages of cashew cake-shell in the blends. The no-interaction might be due to the fact that the main reaction zones are distinctively different for two constituents, so the additive rule is acceptable for describing pyrolysis behavior of the present blends.

탄산칼슘의 비등온 열적거동 (Non-isothermal Behavior of Calcium Carbonate)

  • 손용운;임재원;최국선
    • 한국분말재료학회지
    • /
    • 제16권3호
    • /
    • pp.167-172
    • /
    • 2009
  • This study has been carried out to investigate the non-isothermal behaviors and kinetic parameter of calcium carbonate by different thermal analysis methods. At the heating rate of $10^{\circ}C$/min, the onset calcination temperature, the peak and final temperatures of calcium carbonate were $612^{\circ}C$, $748^{\circ}C$, and $890^{\circ}C$ respectively. As the heating rate of the calcium carbonate increased from $5^{\circ}C$/min to $20^{\circ}C$/min, the peak temperature increased from $719^{\circ}C$ to $782^{\circ}C$. The activation energies of the calcium carbonate calculated by the methods of Kissinger and Freeman-Carroll were 40.15 kcal/mol and 43.47 kcal/mol, respectively.

등온열처리법에 의해 모의 열화된 1Cr-1Mo-0.25V 터빈케이싱 강의 재질열화 평가 (Evaluation of Material Degradation of 1Cr-1Mo-0.25V Turbine Casing Steel Aged Artificially by Isothermal Heat Treatment)

  • 마영화;김도형;윤기봉
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.22-26
    • /
    • 2010
  • Material degradation should be considered to assess integrity and residual life of high temperature equipments. However, the property data reflecting degradation are not sufficient for practical use. In this study, mechanical properties of 1Cr-1Mo-0.25V casting steel generally used for turbine casing were measured and variation of microstructure was observed. Degradation was simulated by isothermal heat treatment.

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

Ni/B/Ni 액상확산접합계의 액상폭에 관한 연구 (A Study on the Width of Liquid Layer of Ni/B/Ni Diffusion Bonding System)

  • 정재필;강춘식
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.147-154
    • /
    • 1995
  • In order to study the bonding mechanism of Ni/B/Ni transient liquid phase bonding system, width of liquid layers were calculated, where in this system melting point of insert material(B) is higher than bonding temperature and melting point of base metal(Ni). Caclulated values were compared with experimental ones which were measured by bonding Ni/B/Ni system at 1433-1474K under vacuum atmosphere. As results, the width of initial liquid layer of Ni/B/Ni system was calculated as $W_{IL}$ = $W_{o}$[1 + {2.100..rho.$_{S/}$ ( $X_{3}$ + $X_{4}$)..rho.$_{Ni}$ }-.rho.$_{S/}$.rho. Ni/], and it was nearly same with experimental values. Maximum width of liquid layer, width of liquid layer during isothermal solidification and isothermal solidification time were calculated also.o.o.o.

  • PDF