• 제목/요약/키워드: isolator

검색결과 469건 처리시간 0.021초

제진장치의 제어기 설계와 실험에 관한 연구 (A Study On The Design Of Control Algorithm For Vibration Isolator And its Experiments)

  • 레당카잉;남택근;노영오
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.219-220
    • /
    • 2011
  • In this paper the construction of vibration isolator using induction motor and its experiments are introduced. The vibration isolator is composed by plate, crank, electric motor and laser sensor to measure the displacement of plate. A control scheme to isolate the vibration signals due to the load variance and disturbance is designed with pole-placement and Routh-Huritz method. Experiments are also applied to confirm the effectiveness of the proposed control scheme.

  • PDF

1.9GHz Band Drop-In Type Isolator 설계 (Design of 1.9GHz Band Drop-In Type Isolator)

  • 김지균;이헌용;이병학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1536-1538
    • /
    • 2000
  • In this paper, designed and fabricated the 1.9GHz band isolator for wire-less communication base-stations. It was investigated that characteristics of insertion loss and return loss. The characteristic results of dual structure design showed values that insertion loss was about -40dB and return loss was about -23dB at 1.93$\sim$1.99GHz.

  • PDF

진동 방지기를 갖는 화강암 광탁자의 설계 및 제작 (Design and Constrvction of a Granite Optical Table with a Vibration Isolator)

  • 송재원;유상대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.98-100
    • /
    • 1987
  • A granite optical table with a vibration isolator system is designed and constrvcted. The table top is made with granite and the vibration isolation system is constrvcted using a pneumatic isolator. The performance of the table is evalvated by the vibration measurement.

  • PDF

교량의 마찰형 지진격리장치 최적 인자 결정에 관한 연구 (A Study on Optimal Design Factors of Frictional bearing for Isolated Bridges)

  • 고현무;박관순;김동석;송현섭
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.451-458
    • /
    • 2002
  • To secure structures from strong earthquakes occurred recently and design economically seismic isolation design is spread rapidly. Specially, frictional isolator has superiority in application to bridge because it has many advantages. however, because isolator lies between pier and girder, responses of pier and superstructure contradict each other and we need to control the two responses to minimize the bridge's failure probability. In this study, frictional coefficient and horizontal stiffness is defined as design parameters of frictional isolator. the optimal design parameters of frictional isolator to minimize the bridge's failure probability are presented according to strength of earthquake and soil conditions. The result says that optimal friction coefficient is higher as the strength of earthquake is increased. And it is also higher as the soils are more flexible. But, optimal horizontal stiffness of rubber spring is insensitive to strength of earthquake and soil condition.

  • PDF

Cyclic behavior of DCFP isolators with elliptical surfaces and different frictions

  • Abdollahzadeh, Gholamreza;Darvishi, Reza
    • Structural Engineering and Mechanics
    • /
    • 제64권6권
    • /
    • pp.731-736
    • /
    • 2017
  • Friction Pendulum isolators are tools developed in the past few decades. The simplest form of these isolators, are FPS whose main disadvantages are having a constant frequency independent of the frequency of the structure. For this reason, researchers have invented VFPI isolator whose frequency is variable and depends on displacement. Another friction pendulum isolator is DCFP isolator which is a combination of two FPS isolators. In this article, first by changing the geometry of DCFP isolator plates from spherical to elliptical, the motion and frequency equations of DVFPI isolators are defined, and then the seismic behavior of DVFPI isolators are analyzed in various geometric and plate friction settings using motion equations, and confirmed using ABAQUS software. The most important results of this study are that the hysteresis behavior of DVFPI isolators are severely nonlinear, its curve follows two distinct curvatures, and that the restoring force is faced with softening mechanism that limits the seismic force transmitted to the structure, whereas the restoring force in DCFP isolators increases linearly with increasing displacement.

A Study on the Control Scheme of Vibration Isolator with Electrical Motor

  • Nam, Taek-Kun;Le, Dang-Khanh
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.133-140
    • /
    • 2012
  • In this study, a reliable control scheme with PID combined controller will be considered. The combined controller in this study is PID algorithm with parameters tuned by using ILC (iterative learning control) approach. The controller was applied to the vibration isolator using an induction motor which works as an actuator. This isolator is developed to eliminate the influence of vibration from rotating machineries on the small ship. The NI cRIO real time controller with FPGA is loaded to get or generate control signals. Crank mechanism which converts rotating energy into translational force is adopted and the relation between control force and torque generated from actuator is also analyzed. A Labview program is composed for controlling practice. Experimental results will be described to show the effectiveness of the proposed control schemes.

에어컨 실내기 팬 모터용 방진고무의 동특성 측정에 관한 연구 (A Study on the Measurement of Dynamic Properties of the Rubber Mount in the Impeller Fan Motor of the Air-conditioner)

  • 최현;김준우;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.185-190
    • /
    • 2001
  • The structure borne noise of the air-conditioner, which degrades the noise quality, is hardly reduced by the general noise treatments. It can be effectively reduced by eliminating the structural vibration which the noise originates from. The rubber vibration isolator prevents the dynamic force induced by the fan driving motor from exciting the chassis structure, which finally reduces the structure borne noise. The dynamic properties of the vibration isolation system such as the natural frequency of the vibration isolation and loss factor of the rubber isolator, need to be experimentally evaluated. In this paper, these dynamic properties were obtained by the resonant method using the impact hammer for 3 types of the isolator specimens. It is known that the isolation natural frequency of the axial direction of the rubber isolator is two times higher than that of the radial direction, and is proportional to the hardness of the rubber specimen.

  • PDF

면진장치 들림 효과를 고려한 면진된 골조의 구조 거동 평가 (Evaluation of Structural Response of Base Isolated Frame Considering Uplift Effect of Isolators)

  • 김대곤
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.69-76
    • /
    • 2010
  • 적층고무 면진장치의 전단강성 뿐만 아니라 인장강성 및 압축강성을 실험적으로 구한 후 비선형 해석 프로그램을 이용하여 면진장치를 모델링 하였다. 수평력을 받는 면진된 골조의 면진장치에 전도에 의한 인장응력이 발생되게 하기 위하여 큰 초기변위를 부여한 자유진동 실험을 해석적으로 수행하였다. 적층고무 면진장치는 인장에 약하기 때문에 면진장치에서의 들림 현상을 해석적으로 구하기 위하여 면진장치의 수직방향 강성들이 해석 모델에 적절히 반영되어야 한다.

  • PDF

Design of the SMD Isolator for IMT-2000 handset

  • 김진섭;윤종남
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2003년도 기술심포지움 논문집
    • /
    • pp.218-220
    • /
    • 2003
  • In this paper, tile SMD isolator for IMT-2000 handset is designed, fabricated and analyzed. We have designed the SMD isolator using EM Simulation tool. Electrical results have improved in comparison with a conventional model. It provides an insertion loss of 0.3 dB at 1.95GHz and an isolation of 21.5 dB or more over a frequency range of 1.92 through 1.99 GHz. The size of the isolator is $4\times4\times1.8mm^3$.

  • PDF

층간소음저감재 장기 내구성 평가를 위한 가열시험의 문제점 및 개선방안에 관한 연구 (A study on the improvement method of heat treatment condition for the long-term stability evaluation in the floor impact isolator)

  • 박연준;이찬규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.238-243
    • /
    • 2011
  • This study compared Kd, loss factor and thickness of floor impact isolator by loading/unloading heat treatment with results by continuous loading treatment and checked problem and improvement method of heat treatment condition for the long-term stability evaluation of the floor impact isolation. As the results, it is required the change of heat treatment condition unloading now to loading as actual weigh on the floor impact isolator.

  • PDF