• 제목/요약/키워드: isolation system

검색결과 1,775건 처리시간 0.035초

진동 파워흐름 측정을 통한 SUV용 엔진 마운트의 에너지 전달 기여도 분석에 관한 연구 (A Study on the Transmitted Energy Contribution Analysis of SUV Engine Mount by Vibration Power Flow Measurement)

  • 김수곤;이상권;김성종
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.400-410
    • /
    • 2008
  • Reduction of structure-borne noise in the compartment of a car is an important task in automotive engineering. Many methods which analyze noise transfer path have been generally used for structure-borne noise. These methods are useful in solving particular problem but do not quantify the effectiveness of vibration isolation for each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow measurement has been used for a simple isolation system or a laboratory based isolation system. This paper identifies the transfer path of booming noise in a SUV. The powertrain used for test has a in-line 4cylinder engine and 5-shift auto-transmission. This powertrain is transversely supported by four isolators. We calculated the energy flow throughout four isolator by the measurement of power flow and the contribution of energy flow at each isolator.

다양한 수동 진동 절연 장치의 진동 절연 특성 비교 (A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator)

  • 이대은;한재흥
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.817-824
    • /
    • 2012
  • 정밀 시스템에 전달되는 진동은 시스템의 성능 저하 및 오작동을 초래할 수 있기 때문에 저감되어야 한다. 진동을 저감시키는 가장 일반적인 방법은 진동이 전달되는 경로에 수동 진동 절연 장치를 도입함으로 전달되는 진동을 절연시키는 방법이다. 탄성소자와 점성 감쇠기로 구성된 일반적인 수동 진동 절연 장치는 공진에서의 전달률을 낮추기 위해서 고주파수 대역에서 진동 절연 성능을 희생해야 하는 단점을 지니고 있다. 이 논문에서는 공진에서 낮은 전달률과 고주파수 대역에서 높은 진동 절연 성능을 동시에 가진 수동 진동 절연 장치들의 특성을 비교 분석하였다.

다양한 수동 진동 절연 장치의 진동 절연 특성 비교 (A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator)

  • 이대은;한재흥
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.232-237
    • /
    • 2012
  • 정밀 시스템에 전달되는 진동은 시스템의 성능 저하 및 오작동을 초래할 수 있기 때문에 저감되어야 한다. 진동을 저감시키는 가장 일반적인 방법은 진동이 전달되는 경로에 수동 진동절연 장치를 도입함으로 전달되는 진동을 절연시키는 방법이다. 탄성소자와 점성 감쇠기로 구성된 일반적인 수동 진동 절연 장치는 공진에서의 전달율을 낮추기 위해서 고주파수 대역에서 진동 절연 성능을 희생해야 하는 단점을 지니고 있다. 본 논문에서는 공진에서 낮은 전달율과 고주파수 대역에서 높은 진동 절연 성능을 동시에 가진 수동 진동 절연 장치들의 특성을 비교 분석하였다.

  • PDF

A novel risk assessment approach for data center structures

  • Cicek, Kubilay;Sari, Ali
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.471-484
    • /
    • 2020
  • Previous earthquakes show that, structural safety evaluations should include the evaluation of nonstructural components. Failure of nonstructural components can affect the operational capacity of critical facilities, such as hospitals and fire stations, which can cause an increase in number of deaths. Additionally, failure of nonstructural components may result in economic, architectural, and historical losses of community. Accelerations and random vibrations must be under the predefined limitations in structures with high technological equipment, data centers in this case. Failure of server equipment and anchored server racks are investigated in this study. A probabilistic study is completed for a low-rise rigid sample structure. The structure is investigated in two versions, (i) conventional fixed-based structure and (ii) with a base isolation system. Seismic hazard assessment is completed for the selected site. Monte Carlo simulations are generated with selected parameters. Uncertainties in both structural parameters and mechanical properties of isolation system are included in simulations. Anchorage failure and vibration failures are investigated. Different methods to generate fragility curves are used. The site-specific annual hazard curve is used to generate risk curves for two different structures. A risk matrix is proposed for the design of data centers. Results show that base isolation systems reduce the failure probability significantly in higher floors. It was also understood that, base isolation systems are highly sensitive to earthquake characteristics rather than variability in structural and mechanical properties, in terms of accelerations. Another outcome is that code-provided anchorage failure limitations are more vulnerable than the random vibration failure limitations of server equipment.

LRB 댐퍼 조합형 지진격리장치 개발 및 특성평가실험 (Development of Seismic Isolation Device with LRB and Shock Transmission Units and Its Verification Tests)

  • 서주원;김남식;임진석;유문식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2002
  • The new seismic isolation system (StLRB) is developed, which can separate non-seismic displacements which come from the thermal expansion etc. in LRB design. The StLRB has 3 components, sliding system (PTFE + stainless plate), LRB (lead rubber bearing) and STU (shock transmit units). In this project, the StLRB is designed to apply to the bridge structure by analyzing the characteristics of each component and also the dynamic behavior of the structure was analyzed by non-linear analysis. The verification test was performed to show the two stages separated by STU units. Test results show the effectiveness of both the separation and the seismic isolation performance.

  • PDF

3자유도 능동형 제진 시스템의 불확실성과 제어 (Uncertainties and control of a 3-DOF active vibration isolation system)

  • 김화수;박희재;문준희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.925-933
    • /
    • 2006
  • Using the physics-based model for the vibration isolation system, the model uncertainties are described. With the model including parameter perturbations, the robust controller to meet the robust performance and stability is designed through $\mu$-synthesis by DK-iteration. The order of controller is reduced by virtue of Hankel norm approximation technique to allow the efficient implementation in the real-time experimental environment without any performance degradation. The performance of the reduced $\mu$-controller is accessed in comparison with the original one. The experiments validate the superiority of the proposed control scheme against the model uncertainties and its applicability with varying payload.

  • PDF

3자유도 능동형 제진 시스템의 불확실성과 제어 (Uncertainties and Control of a 3-DOF Active Vibration Isolation System)

  • 김화수;박희재;조영만;문준희
    • 한국소음진동공학회논문집
    • /
    • 제16권12호
    • /
    • pp.1262-1271
    • /
    • 2006
  • Using the physics-based model for the vibration isolation system, the model uncertainties are described. With the model including parameter perturbations, the robust controller to meet the robust performance and stability is designed through $\mu$-synthesis by DK-iteration. The order of controller is reduced by virtue of Hankel norm approximation technique to allow the efficient implementation in the real-time experimental environment without any performance degradation. The performance of the reduced $\mu$-controller is accessed in comparison with the original one. The experiments validate the superiority of the proposed control scheme against the model uncertainties and its applicability with varying payload.

Experimental Study on Seismic Performance of Base-Isolated Bridge

  • Chung, Woo Jung;Yun, Chung Bang;Kim, Nam Sik;Seo, Ju Won
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.51-60
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

역진자 제어계의 고장검출식별 기법 (Fault Detection and Isolation Scheme for Inverted Pendulum Control System)

  • 이상문;류지수;이기상;박태건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2227-2229
    • /
    • 2004
  • Fault Detection and Isolation(FDI) schemes using unknown input functional observers with very low order are presented. These schemes resolve the major practical difficulties with all FDI systems employing multiple observers for residual generation and can be implemented by the use of microprocessors that are normally used in commercial processes mainly due to the simplicity of the residual generation block. Various design objectives including detection, isolation, estimation and compensation of instrument fault/or process fault are achievable with these schemes. The proposed FDI scheme is applied to an inverted pendulum control system for instrument fault detection.

  • PDF

면진 LRB(Lead Rubber Bearing) 시스템의 유한요소 해석 및 설계 (Finite Element Analysis and Design of a Lead-Rubber-Bearing System for Seismic Isolation)

  • 송우진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.229-232
    • /
    • 1999
  • The seismic isolation technology has appeared to be increasingly necessary for highway brides LNG tank nuclear power plant and building structures in view of recent frequent earthquake vibrations in Korea. Also high-technology industries required effective seismic protection. The LRB(Lead Rubber Bearing) systen has been counted as the most effective way for seismic isolation which is now under development and widely used in industries. Hear the commercial FEM software for nonlinear analysis MARC has provided force-displacement curves on the rubber system. The analysis has been carried out about four cases ; 29.5mm and 59mm horizontal dislacements with/without a center hole. The unknown constants of the strain energy function of Ogden model have been obtained by a tension test,

  • PDF