• Title/Summary/Keyword: isolation system

Search Result 1,778, Processing Time 0.026 seconds

Base-isolated building with high-damping spring system subjected to near fault earthquakes

  • Tornello, Miguel Eduardo;Sarrazin, Mauricio
    • Earthquakes and Structures
    • /
    • v.3 no.3_4
    • /
    • pp.315-340
    • /
    • 2012
  • There are many types of seismic isolation devices that are being used today for structural control of earthquake response in buildings. The most commonly used are sliding bearings and elastomeric bearings, the latter with or without lead core. An alternative solution is the use of steel springs combined with viscoelastic fluid dampers, which is the case discussed in this paper. An analytical study of a three-story building supported on helical steel springs and viscoelastic fluid dampers, GERB Control System (GCS), subjected to near-fault earthquakes is presented. Several earthquakes records have been obtained by the acceleration network installed in the isolated building and in its non-isolated twin since they were finished. These experimental results are analysed and discussed. The aim is to show that the spring-based system can be an alternative for base isolation of small building located near active faults.

Reducing Effect Analysis on Earthquake Response of 100m Spanned Single-Layered Lattice Domes With LRB Seismic Isolation System (LRB 면진 장치를 갖는 100m 단층 래티스 돔의 지진 응답에 대한 감소 효과 분석)

  • Park, Kang-Geun;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.53-64
    • /
    • 2019
  • The objective of this study is to investigate the earthquake response for the design of 100m spanned single-layer lattice dome. The plastic hinge analysis and eigenvalue buckling analysis are performed to estimate the ultimate load of single-layered lattice domes under vertical loads. In order to ensure the stability of lattice domes, it is investigated for the plastic hinge progressive status by the pushover increment analysis considering the elasto-plastic connection. One of the most effective methods to reduce the earthquake response of large span domes is to install the LRB isolation system of a dome. The authors discuss the reducing effect for the earthquake dynamic response of 100m spanned single-layered lattice domes. The LRB seismic isolation system can greatly reduce the dynamic response of lattice domes for the horizontal and vertical earthquake ground motion.

Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch (침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가)

  • Hong, Ki-Ho;Chang, Duk;Han, Sang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.

Evaluation of Torsional Vibration Isolation Damper in Automotive Transmissions Based on In-situ Torque Measurement (토크 측정을 이용한 차량 변속기용 비틀림 진동 절연 댐퍼 평가)

  • Kim, Gi-Woo;Jang, Jae-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.4
    • /
    • pp.377-382
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

Performance of multi-storey structures with high damping rubber bearing base isolation systems

  • Karabork, Turan
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.399-410
    • /
    • 2011
  • Base isolation, having quite simple contents, aims to protect the buildings from earthquake-induced damages by installing structural components having low horizontal stiffness between substructure and superstructure. In this study, an appropriate base isolation system for 2-D reinforced concrete frame is investigated. For different structural heights, the structural systems of 2, 3 and 4 bays are modeled by applying base isolation systems and results are compared with conventional structural systems. 1999 Marmara earthquake data is used for applying the model by time history method in SAP2000 package. Results of various parameters such as base shear force, structure drift ratio, structure period and superstructure acceleration are discussed for all models.

Isolation Circuits Based on Metamaterial Transmission Lines for Multiplexers(Invited Paper)

  • Lee, Hanseung;Itoh, Tatsuo
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.141-150
    • /
    • 2013
  • Multiplexers based on isolation circuits made of metamaterial lines are proposed and studied. The new approach provides unique advantageous features beneficial to system designer. For instance, there is no need to modify the filters used in multiplexers. Also, the design process is straightforward. In this paper, two types of multiplexers based on metamaterial isolation circuits are presented, and their operation concepts are explained. Also, theories and design process of isolation circuits are presented to help readers design and fabricate proposed multiplexers. For verifying the concepts, two types of triplexers and two types of quadruplexers are designed and fabricated. All filters used in the multiplexers are commercial surface acoustic wave filters. The measured results are well matched with the simulation results.

Evaluation of Torsional Vibration Isolation Performance Using In-situ Driveline Output Torque Measurement (구동 출력 토크 측정을 이용한 비틀림 진동 절연 성능 평가)

  • Kim, Gi-Woo;Jang, Jae-Duk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.382-387
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

  • PDF

A Study on Improved Isolation of Indoor Repeating Antenna using Metamaterial Absorber for WCDMA System

  • Kim, Hyoungjun;Moon, Yong;Seo, Chulhun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.850-855
    • /
    • 2013
  • This paper proposes a novel design for a compact, high-isolation WCDMA indoor repeater antenna. The proposed antenna consists of a patch antenna and metamaterial absorber. The required WCDMA bandwidth is obtained by utilizing the coupling between the main and the parasitic patches. In addition, high isolation is achieved using the metamaterial absorber, which has an absorption of about 98% at 2.1 GHz. Overall, the proposed antenna has a gain of over 7 dBi, a Voltage Standing Wave Ratio (VSWR) of less than 2, more than 85 dB of isolation between the service and donor antennas over the WCDMA band and a total volume of the proposed antenna only $70mm{\times}70mm{\times}43.8mm$.

Effects of the nonlinear behavior of lead-rubber bearings on the seismic response of bridges

  • Olmos, B.A.;Roesset, J.M.
    • Earthquakes and Structures
    • /
    • v.1 no.2
    • /
    • pp.215-230
    • /
    • 2010
  • The main objectives of this work were to investigate the effects of the nonlinear behavior of the isolation pads on the seismic response of bridges with rubber bearings, and to identify when base isolation improved their seismic performance. To achieve these objectives a parametric study was conducted designing a set of bridges for three different soil types and varying the number of spans, span lengths, and pier heights. The seismic responses (accelerations, displacements and pier seismic forces) were evaluated for three different structural models subjected to three earthquakes with different dynamic characteristics. The first represented bridges without base isolation; the second corresponded to the same bridges including now rubber bearings as an isolation system, with linear elastic behavior that shifted the natural period of the bridge by a factor of 2 to 4. In the third model the seismic response of bridges supported on lead-Rubber bearings was studied accounting for the nonlinear behavior of the lead. The results show clearly the importance of the nonlinear behavior on the seismic performance of the bridges.

Experimental Performance Verification of Energy-Harvesting System Using the Micro-vibration of the Spaceborne Cryocooler (우주용 냉각기의 미소진동을 이용한 에너지 수확 시스템의 실험적 성능검증)

  • Jung, Hyunmo;Kwon, Seongcheol;Oh, Hyunung
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.3
    • /
    • pp.15-22
    • /
    • 2016
  • The on-board appendages of satellites with mechanical moving parts such as the fly-wheel, the control-moment gyro, the cryocooler, and the gimbal-type directional antenna can generate an undesirable micro-vibration disturbance, which is one of the main causes of the image-quality degradation that affects high-resolution observation satellites. Consequently, the isolation of the micro-vibration issue has always been considered as salient, and the micro-vibration is therefore the focus of this study wherein a complex system that can provide the dual functions of a guaranteed vibration-isolation performance and electrical energy harvesting is proposed. The vibration-isolation and energy-harvesting performances of the complex system are predicted through a numerical analysis based on the characteristics that are obtained from component-level tests. In addition, the effectiveness of the complex system that is proposed in this study is verified through an assembly-level functional-performance test.