• Title/Summary/Keyword: isolation floor

Search Result 141, Processing Time 0.025 seconds

Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High-Rise Building (고층 건물에 적용한 면진 시스템의 설치 위치에 따른 지진 응답 분석)

  • Kim, Min-Ju;Kim, Dong-Uk;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.81-88
    • /
    • 2018
  • Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.

Noise and Vibration Characteristics by Heavy-weight Floor Impact (중량바닥충격에 의한 소음 및 진동 특성)

  • 서상호;송희수;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.919-922
    • /
    • 2003
  • The correlation between noise and vibration by a heavy-weight floor impact was studied. The triggering technique was used for increasing the reliability and stability to measure the level of sound pressure, sound intensity and vibration acceleration. The simple finite element and rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The result show that the isolation material adapted to reduce the light-weight floor impact noise, causing the natural frequency lower, make resonance with dominant driving frequency, and increase the noise level very sharply. Therefore the noise level Peak in the region of low frequency, below 63Hz, would be related with the natural frequencies of the floor system.

  • PDF

Investigating of a Floor-Impact Isolation System Using Damping Materials In Apartment Buildings (공동주택에서 완충재를 이용한 바닥충격음 저감 System 연구)

  • 송희수;정영;정정호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.499-504
    • /
    • 2004
  • The purpose of this study is to investigate a investigating of a floor-impact isolation system using damping materials in apartment buildings. The stiffness elastic modulus(k) by puls impact forces were calculated loss factor by Hilbert transforms. It is absolved that natural frequency was moved floor shock-absorbing materials and the impact force was reduced by floor panel. The slab was constructed by damping materials. As towards a result, the system showed inverse A 45dB by heavy weight-impact noise and inverse A 52dB by light-impact noise. High frequencies impact-noise can be reduced by upgrading naturial frequency of vibration and noise in the system.

  • PDF

Reduction Method for Floor Impact Noise on APT Remodeling (공동주택 리모델링 현장의 바닥충격음 저감대책)

  • Park, Cheol-Yong;Hong, Goo-Pyo;Lee, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.524-525
    • /
    • 2009
  • Heavy-weight impact noise(HN) is the most irritating noise in Korean apartment houses. It has been proclaimed standard floor system of 210mm thick slab with isolation material in the wall type structure. But this regulation is applied only new construction field and is not considered remodeling field. In general, the LN can be reduced by using isolation material but HN is known as relating with stiffness, strength & boundary condition of slab. Therefore it is difficulty in improving the HN on remodeling field. In this study, We conducted the reinforcement of concrete slab using C.F.S.(carbon fiber sheet), steel plate and steel beam after on-dol with isolation material on the remodeling field. As the test results, It appeared using C.F.S was no improved but using steel plate & steel beam were a little improved on HN.

  • PDF

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

Remotely Operated Decontamination Systems for Use in DFDF

  • Kim, Kiho;Park, Jangjin;Myungseung Yang
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.438-446
    • /
    • 2003
  • This paper presents the development of the remotely operated decontamination systems for use in a highly radioactive zone of the DUPIC Fuel Development facility of the Irradiated Material Examination Facility at the Korea Atomic Energy Research Institute. The remotely operated decontamination systems were designed to completely eliminate human interaction with hazardous radioactive contaminants. These decontamination systems are mainly classified into three systems depending on the task environment - a fabrication equipment decontamination system, a hot-cell floor decontamination system, and an isolation room floor decontamination system. A decontamination system for contaminated fabrication equipment utilizes dry ice pellet blasting method to decontaminate contaminated surface of the equipment. The decontamination systems for the hot-cell floor and isolation room floor employ a vacuum cleaning method to decontaminate the contaminated floor and collect loose dry spent nuclear fuel debris and other radioactive waste placed on the floor. The human operator from the out-of-cell performs a series of decontamination tasks remotely by manipulating decontamination systems located in-cell via a handcontroller with the aid of vision feedback information. The environmental, functional and mechanical design considerations, control system and capabilities of the remotely operated decontamination systems at a high radioactive environment are also described.

  • PDF

Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System (중간층 면진시스템 설치 위치에 따른 고층건물의 지진응답 분석)

  • Kim, Ka-Yeong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.85-92
    • /
    • 2017
  • Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the $1^{st}$ floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.

Evaluation of Floor Impact Sound Performance according to the Reduction Methods (바닥충격음 저감방안에 따른 성능평가)

  • 김경우;최경석;최현중;양관섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.131-136
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

  • PDF

Evaluation of Floor Impact Sound Performance according to the Reduction Methods (바닥충격음 저감방안에 따른 성능평가)

  • Choi Gyoung-Seok;Choi Hyun-jung;Yang Kwan-Seop;Kim Kyoung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.811-818
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

The Analysis of Perceptual Levels For Floor Impact Noises in Apartments (공동주택에서의 바닥충격음 인지도 분석)

  • 김경호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.598-603
    • /
    • 2002
  • The floor impact noise in apartment buildings has been known as the most sensitively recognized environmental noise. Therefore. inhabitants perceptual evaluation of floor impact noises was investigated by a questionnaire survey. It was found that the respondents perceive the floor impact noises from the upper nor as a constant noise level. However, if there is any child on the upper floor. the respondents felt Its noise as a harshly grating level. It was also found that the larger the respondents house is. the higher their wanted level of noise isolation is. Moreover, it was revealed that the main source of the floor impact noise from the upper floor is a child at the age from six to seven. The results could be used as fundamental data for the research on impact sources and new regulations that fit to Korean perceptual aspects and characteristics.

  • PDF