• 제목/요약/키워드: isolation bearing

검색결과 246건 처리시간 0.024초

지진격리설계된 RC교각의 유사동적 실험 (Pseudo Dynamic Test of the Seismically Isolated RC Piers)

  • 김영진;곽임종;조창백;곽종원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.25-28
    • /
    • 2004
  • Many highway bridges in Korea need seismic retrofit because only one decade has passed since the seismic design criteria was introduced. In this experimental study, the effectiveness of base isolation bearings was discussed for the seismic retrofit of the highway bridges. Four real scale RC pier specimens were constructed for the test. These RC piers didn't have seismic details. Except for one RC pier for the pilot test, three types of bearings such as Pot bearing, Rubber bearing (RB), Lead-rubber bearing (LRB) were applied to the other RC piers respectively. The RC pier with Pot bearing means current state of the prototype bridge that is not retrofitted seismically. And two RC piers with RB or LRB mean assumed states of the prototype bridge that are retrofitted seismically. To simulate dynamic behavior of these RC piers under earthquake loads, Pseudo-dynamic test method was used.

  • PDF

면진받침의 내진성능평가를 위한 실험 시 속도의존성과 수직하중의 영향 (Investigating the Influence of Rate Dependency and Axial Force on the Seismic Performance Evaluation of Isolation Bearing)

  • 박민석;채윤병;김철영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.22-29
    • /
    • 2023
  • 재료 및 부재의 내진성능평가 실험 시 재하속도와 수직하중은 성능에 중대한 영향을 미칠 수 있다. 반복 가력 및 하이브리드 실험 시 재하속도는 입력 변위와 출력 변위 사이의 시간 지연현상으로 인해 고속으로 제어하기 어려우며 횡방향 변위에 의해 수직하중을 일정하게 유지하는 것이 어려워 일정한 수직하중이 유지되는 고속 및 실시간 실험은 거의 이루어지지 않았다. 본 연구에서는 면진받침의 속도 의존성과 수직하중의 영향을 조사하기 위해 저속 및 고속 반복 가력 실험과 실시간 하이브리드 실험을 수행하였다. 실험에서 수평 변위와 수직 하중의 실시간 제어를 위해 Adaptive Time Series(ATS) 보정 방법과 State estimator가 포함된 FLB System을 구축하였다. 고속 또는 실시간으로 재하되는 수평 변위 제어 속도와 상부구조물에 의한 수직하중은 면진받침의 강도 및 지진 시 거동에 상당한 영향을 미칠 수 있음을 확인하였으며 내진성능평가를 위한 실험 시 실제와 유사하도록 구현되어야함을 알 수 있었다. 본 연구는 내진성능평가를 위해 구축하고 사용된 시스템의 우수한 성능을 보여주며 정확하고 효율적인 내진성능평가가 가능하도록 하였다.

Design of Seismic Isolated Tall Building with High Aspect-Ratio

  • Kikuchi, Takeshi;Takeuchi, Toru;Fujimori, Satoru;Wada, Akira
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2014
  • When seismic isolation system is applied to high aspect-ratio (height/wide-ratio) steel structures, there are several problems to be taken into consideration. One is lifting up tensile force on the isolation bearing by overturning moment caused by earthquake. Another is securing building stiffness to produce seismic isolation effects. Under these conditions, this paper reports the structural design of high-rise research building in the campus of Tokyo Institute of Technology. With the stepping-up system for the corner bearings, the narrow sides of single span framework are designed to concentrate the dead load as counter-weight for the tensile reaction under earthquake. Also we adopted concrete in-filled steel column and Mega-Bracing system covering four layers on north & south framework to secure the horizontal stiffness of the building.

300m 단층 래티스 돔의 면진 장치에 대한 지진 반응 해석 (Earthquake Response Analysis for Seismic Isolation System of Single Layer Lattice Domes With 300m Span)

  • 박강근;정미자;이동우
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.105-116
    • /
    • 2018
  • The objective of this study is to investigate the response reducing effect of a seismic isolation system installed between 300m dome and supports under both horizontal and vertical seismic ground motion. The time history analysis is performed to investigate the dynamic behavior of single layer lattice domes with and without a lead rubber bearing seismic isolation system. In order to ensure the seismic performance of lattice domes against strong earthquakes, it is important to investigate the mechanical characteristics of dynamic response. Horizontal and vertical seismic ground motions cause a large asymmetric vertical response of large span domes. One of the most effective methods to reduce the dynamic response is to install a seismic isolation system for observing seismic ground motion at the base of the dome. This paper discusses the dynamic response characteristics of 300m single layer lattice domes supported on a lead rubber seismic isolation device under horizontal and vertical seismic ground motions.

라이즈-스팬비에 따른 면진 아치구조물의 지진응답 분석 (The Seismic Response According to Rise-Span Ratio of the Arch Structure With Seismic Isolation)

  • 김수근;김유성;김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2018
  • In order to reduce the seismic response of the spatial structure, a seismic isolation system with sufficient flexibility is used. The natural period of structure with seismic isolation system got be long to avoid prominent period. In this study, The seismic response of the truss-arch structure, which is modeled in three types according to the rise-span ratio is analyzed on El-centro, Northridge and Artificial Earthquake and compared with the seismic response of the truss-arch structure with lead rubber bearing(LRB). When seismic load is applied to the truss arch with isolation system, the horizontal acceleration response of the truss arch is reduced and vertical seismic response is also reduced. The application of the seismic isolation system is effective in controlling the seismic response.

LNG 저장탱크의 면진시스템 적용을 위한 내진설계 (Seismic design for application of LNG storage tank isolation system)

  • 서기영;박현재;양성영;김남식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.132-138
    • /
    • 2013
  • Natural gas as a clean fuel of the world demand for the trend is gradually increasing demand for clean energy in the country and there is growing interest. Therefore, LNG storage tanks and related facilities in the country of the importance of leading a community-based facility has emerged. So common sense that an earthquake with a seismic isolation device LNG storage tank similar to the actual behavior of the analytical model which can describe the development and construction of storage tanks to enhance the safety and economic design techniques need to be developed. In this study, a base isolation system, seismic analysis procedure of LNG storage tanks, and Triple-FPB developed a mathematical model of the present crystallized and complexity factors to the sum over histories model simplifies the complex behavior of the LNG storage tank with base isolation system how to interpret the seismic isolation is proposed.

  • PDF

Experimental and analytical study of a new seismic isolation device under a column

  • Benshuai Liang;Guangtai Zhang;Mingyang Wang;Jinpeng Zhang;Jianhu Wang
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.415-428
    • /
    • 2023
  • Low-cost techniques with seismic isolation performance and excellent resilience need to be explored in the case of rural low-rise buildings because of the limited buying power of rural residents. As an inexpensive and eco-friendly isolation bearing, scrap tire pads (STPs) have the issue of poor resilience. Thus, a seismic isolation system under a column (SISC) integrated with STP needs to be designed for the seismic protection of low-rise rural buildings. The SISC, which is based on a simple exterior design, maintains excellent seismic performance, while the mechanical behavior of the internal STP provides elastic resilience. The horizontal behaviors of the SISC are studied through load tests, and its mechanical properties and the intrinsic mechanism of the reset ability are discussed. Results indicate that the average residual displacement ratio was 24.59%, and the reset capability was enhanced. Comparative experimental and finite element analysis results also show that the load-displacement relationship of the SISC was essentially consistent. The dynamic characteristics of isolated and fixed-base buildings were compared by numerical assessment of the response control effects, and the SISC was found to have great seismic isolation performance. SISC can be used as a low-cost base isolation device for rural buildings in developing countries.

Sloped rolling-type bearings designed with linearly variable damping force

  • Wang, Shiang-Jung;Sung, Yi-Lin;Hong, Jia-Xiang
    • Earthquakes and Structures
    • /
    • 제19권2호
    • /
    • pp.129-144
    • /
    • 2020
  • In this study, the idea of damping force linearly proportional to horizontal isolation displacement is implemented into sloped rolling-type bearings in order to meet different seismic performance goals. In addition to experimentally demonstrating its practical feasibility, the previously developed analytical model is further modified to be capable of accurately predicting its hysteretic behavior. The numerical predictions by using the modified analytical model present a good match of the shaking table test results. Afterward, several sloped rolling-type bearings designed with linearly variable damping force are numerically compared with a bearing designed with conventional constant damping force. The initial friction damping force adopted in the former is designed to be smaller than the constant one adopted in the latter. The numerical comparison results indicate that when the horizontal isolation displacement does not exceed the designed turning point (or practically when subjected to minor or frequent earthquakes that seldom have a great displacement demand for seismic isolation), the linearly variable damping force design can exhibit a better acceleration control performance than the constant damping force design. In addition, the former, in general, advantages the re-centering performance over the latter. However, the maximum horizontal displacement response of the linearly variable damping force design, in general, is larger than that of the constant damping force design. It is particularly true when undergoing a horizontal isolation displacement response smaller than the designed turning point and designing a smaller value of initial friction damping force.

아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용 (Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure)

  • 강주원;김현수
    • 한국전산구조공학회논문집
    • /
    • 제24권2호
    • /
    • pp.157-165
    • /
    • 2011
  • 지진하중이 가해지는 구조물의 동적응답을 줄이기 위해서 면진장치가 널리 사용되고 있다. 근래에 들어서는 면진층의 변위를 증가시키지 않으면서도 면진된 구조물의 동적응답을 효과적으로 줄일 수 있는 스마트 면진시스템에 대한 연구가 활발히 이루어지고 있다. 이에 본 연구에서는 지진하중을 받는 아치구조물의 동적응답을 저감시키기 위하여 스마트 면진시스템을 적용하였고 제어성능을 검토하였다. 스마트 면진시스템을 구성하기 위하여 4kN 용량의 MR 감쇠기와 저감쇠 탄성 고무베어링을 사용하였다. 제안된 스마트 면진시스템의 제어성능을 검토하기 위하여 최적설계된 LRB와 지진응답 제어성능을 비교하였다. 이를 위하여 KBC2009 설계응답스펙트럼에 맞추어 생성한 인공지진파를 지진하중으로 사용하였다. 스마트 면진시스템의 MR 감쇠기를 제어하기 위하여 퍼지제어기를 사용하였으며, 다목적 유전자알고리즘을 이용하여 최적화하였다. 수치해석결과 스마트 면진시스템을 사용하면 LRB를 사용한 경우와 비교하여 면진층 변위와 아치구조물의 지진응답을 크게 줄일 수 있음을 확인하였다.

하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화 (Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.