• Title/Summary/Keyword: irradiation distance

Search Result 169, Processing Time 0.029 seconds

Effect of X-Irradiation on the Levels of some Sulfhydryl Groups, Protein and Cell Volume of Ehrlich Ascites Tumour Cells (X-선(線) 조사(照射)가 Ehrlich 암세포(癌細胞)의 용적(容積), 단백양(蛋白量) 및 수종(數種) Sulfhydryl 기(基)에 미치는 영향(影響)에 관(關)하여)

  • Yu, Choon-Shik;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.3 no.2
    • /
    • pp.9-16
    • /
    • 1969
  • It is well known that a number of -SH and -SS containing substances afford a certain measure of protection against radiation effects in many biological systems, and it is conceivable that inherent -SH levels in Ehrlich ascites tumour (ELD)cells may be of decisive improtance with respect to the development of cellular radiation injury. So far, little effort has been directed to elucidate the changes in levels of different -SH and -SS groups in ELD cells when the tumour-bearing whole animal was subjected to the sublethal dose of X-irradiation. The present study was designed to bring some lights in the possible changes of and relationship between various sulfhydryl levels, such as P-SH, NP-SH and NP-SS, as well as the content of protein and cell volume of ELD cells, after subjecting the ELD mice to 1,200 r of X-irradiation. The animals used in this experiment were all mixed bred mice of $20{\sim}25\;gm$ in body weight (approximately 2 months old) irrespective of sex. 12 mice in one experiment were inoculated intraperitoneally with 0.2 ml of ascites tumour cells $(2{\times}10^6\;cells)$, and on the 7th day of the tumour growth, they were X-irradiated with 1,200 r, using the conventional X-ray machine under the following conditions: 200 Kv at 15 mA, 0.5 mm Cu filter, target-skin distance: 50 cm. Radiation dose was measured with the the Philip integrating dosimeter. At 24, 36, 48 and 60 hours after the X-irradiation, the mice were killed by cervical dislocation, and the tumours were taken out. Freshly withdrawn ascites tumours were placed in ice, and immediately the cell concentration was measured with the Coulter Cell Counter (Model B), and the hematocrit of the tumour cells were also determined. Cell volume was thus calculated by the cell concentration and hematocrit value. P-SH content of ELD cells was measured potentiometrically according to the method of Calcutt & Doxey, and NP-SH and NP-SS contents were measured spectrophotometrically by the method described by Ellman. Protein content of ELD cells was determined with the Folin phenol reagent by Lowry et al. Altogether, 48 experimental mice were used, and 12 mice with the only exception of X-irradiation were used as the control. Results obtained indicate that the contents of all the cellular sulfhydryl groups as well as cell volume and protein content of the ELD cells increase significantly as time progresses after the sub-lethal X-ray dose of 1,200 r was given and that all the increase is in a lineal fashion. The regression lines of the relative values, (i. e., taking each control value as 1) of all the values obtained, and the regression lines of cell volume, protein and NP-SH are identical, whereas those of NP-SS and P-SH appear to be widely seperated. However, the difference of those two lines (NP-SS & P-SH) were found to be not significant statistically (p>0.05). Therefore, it can be concluded from the above results that all the values examined increase in a lineal fashion with no statistically significant difference among them. Also, with the radiation dose of 1,200 r, the ELD cell becomes enlarged and swollen progressively up to 60 hours post-irradiation and it becomes more than two times of the original normal size at 60 hours after the irradiation, and up to this stage, it seems apparent that the cell division has been slow due to the X-irradiation applied in this experiment. It is well understandable that the contents of NP-SH, NP-SS, P-SH and protein of the ELD cells increase in parallel with the increase of the cell volume by the X-ray does used, but it also seems interesting to note that all the cellular substances tested show no appreciable difference in the pattern of increase.

  • PDF

Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration (X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향)

  • In Suck Park;Won-Jeong Lee;Sang-Bok Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1171-1178
    • /
    • 2023
  • In study, we investigated changes on growth and chlorophyll concentration on sprouted barley by fractionated X-ray irradiation (FXI). Group was divided into the control group (CG), 1-time irradiation group (30 Gy once), 2-time irradiation group (15 Gy 2 times), and 3-time irradiation group (10 Gy 3 times), and 20 grains were used per group. Experimental group (EG) was exposed by using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18×10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in 9th day. Data analysis was performed the One-way ANOVA using SPSS ver 26.0(Chicago, IL, USA). In the pre-germination irradiation group (Pre-GIG), the CG had greater length than the EG on all measurement days, and as the number of FXI increased, the length became shorter. In the post-germination irradiation group (Post-GIG), the length of the CG was statistically significantly greater than that of the EG on all measurement days, and as the number of FXI increased, the length also became longer. The chlorophyll concentration was higher in the Post-GIG than in the Pre-GIG, and chlorophyll concentrations of EG was higher in the Pre-GIG than in the CG, as well as and Post-GIG. In addition, the smaller the number of FXI, the higher the chlorophyll concentration in both groups. FXI was found to affect the growth and chlorophyll concentration of sprouted barley.

A study on the Interior Structure and Scattered Radiation Measurement of Radiotherapy Room (방사선 치료실의 실내 구조와 산란선 측정에 관한 연구)

  • Kim, Min-Ae;Kwon, Yong-Dae;Je, Jae-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.191-195
    • /
    • 2012
  • This research aims at examining the amount of scattered radiation generated during irradiation by adhering structures with different sizes of aluminum prominence and depression to the inside of a radiotherapy room. The irregular aluminum structures were stuck to the wall of a radiotherapy room, and the scattered radiation generated during irradiation was measured. The sizes of the aluminum prominence and depression were $1.5{\times}1.5$, $3{\times}3$, and $5{\times}5\;cm^2$ with the width of 60 cm and the height of 60 cm. The distance between TLD and the wall of the radiotherapy room to measure scattered radiation was 310 cm, and the used radiation energy was 6 MV and 15 MV generated from a linear accelerator. The research result showed that the irradiation amount at 6 MV was 100, and at 300 cGy the scattered radiation decreased by the installation of the structure with aluminum prominence and depression, but at 200 cGy, only the scattered radiation of the uneven structure of $5{\times}5\;cm^2$ decreased. At 15 MV, the irradiation amount was 200 cGy, and at 300 cGy, the scattered radiation was reduced when the rugged aluminum structure was set up, but at 100 cGy, similar result values were produced regardless of the uneven structure. Consequently, installation of an additional structure with aluminum prominence and depression in the present interior structure can decreased the stochastic effect of the scattered radiation generated from the wall of a radiotherapy room and patients.

Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator (6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구)

  • Lee, Cheol-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Decomposition of EVA(Ethylene vinyl acetate) used as an adhesion of photovoltaic(PV) module by ultrasonic irradiation in bath-type cleaner (Bath-type 초음파(超音波) 세척기(洗滌器)를 이용(利用)한 태양전지모듈 접착제(接着劑) EVA(Ethylene Vinyl Acetate) 분해특성(分解特性))

  • Kim, Young-Jin;Lee, Jae-Ryeong
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • Using ultrasonic irradiation, the separation and recovery of PV cell, made of silicon wafer, from PV module was carried out through selective decomposition of EVA used as an interlaminated binder. The ultrasonic cleaner of bath-type (Output: 130 W, Frequency: 40 kHz) was used as an ultrasonic apparatus in this research. With the fixed distance of 2 cm, from ultrasonic generator to PV cell, the experiment of EVA decomposition was performed in various organic solvents such as Toluene, Trichloroethylene, O-dichlorobenzene, Benzene. And also their concentrations and temperature was changed to survey the optimum conditions. However EVA can be decomposed perfectly at $55^{\circ}C$ within 160 min in 5 M of all kinds of solvent, PV cell may be recovered with being damaged or broken severely. This damage may be resulted from the swelling of EVA in the process of decomposition. Whereas, at the condition of 5 M at $65^{\circ}C$, PV cell can be recovered with the state of minor damage or crack. This implies that the decomposition rate of EVA increases with an increase of temperature, thereby EVA can be decomposed before the swelling of EVA layer. Conclusively, it is possible for PV cell to be recovered within 40 min, at $65^{\circ}C$ in 5 M, with less damage.

Fine Structure on the Epidermis of the Scalp of the Head-Irradiated Rats (방사선 조사를 받은 흰쥐 머리피부 표피층의 미세구조)

  • Ko, Jeong-Sik;Kim, Jae-Ho;Yang, Nam-Gil;Ahn, E-Tay;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.63-77
    • /
    • 1994
  • This experiment was performed to study the morphological responses of the epidermis of the rat scalp, following X-ray irradiation. Male rats were divided into normal and experimental groups. Rats anesthetized with sodium thiopental, were exposed only on their head areas with a single dose of 3,000rads or 6,000rads, respectively. Radiation was produced by Mitsubishi Linea Accelerator ML-4MV at the speed of 200rads/min. The target distance was 80cm. Animals were sacrificed on six hours, two days and six days following irradiation. By the perfusion fixation through the heart, rats were fixed with 1% glutaraldehyde-1% paraformaldehyde solution. Pieces of the tissue taken from the scalp were refixed in 2.5% glutaraldehyde-1.5% paraformaldehyde solution, followed by post-fixation with 1% osmium tetroxide, and embedded within araldite mixture. The sections were cut on a LKB-V ultratome, stained with uranyl acetate and lead citrate, and were observed with JEM 100CX-II electron microscope. The results were as follow; 1. Six hours after exposure to 3,000rads of X-ray. Disrupted intercellular spaces, within which some amorphous materials were filled, disrupted mitochondria, and vacuoles in the keratinocytes were frequently observed, but six days after exposure to 3,000rads of X-ray, Morphology of the keratinocytes was generally restored. 2. Many of the morphological changes were seen on the six days after exposure to 6,000rads of X-ray. 3. Widened intercellular spaces and thickened dense plaques of the desmosomes were frequently observed after exposure to 6,000rads of X-ray. 4. In the experimental groups, the Langerhans and the Merkel cells were damaged, similarly to the keratinocyte. Above results suggest that head irradiation with the dose of 3,000rads temporarily damaged the epidermis of the scalp, though most of the structures recover within six days, whereas with the dose of 6,000rads it severely damaged the epidermis without showing any recovering tendency.

  • PDF

Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration (디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동)

  • Park, Jung-Hoon;Choi, Nak-Sam
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.125-132
    • /
    • 2020
  • The polymerization shrinkage behavior of dimethacrylate-based composite (Clearfil AP-X, Kuraray) and silorane-based composite (Filtek P90, 3M ESPE) used for dental composite restorations was measured using digital image correlation method. The stress distribution on the surface of specimen was calculated by finite element analysis with equivalent elastic modulus and was compared with the measured shrinkage distribution. Camera images were monitored by a CCD camera during and after the irradiation of light. As a result of the DIC analysis, a non-uniform shrinkage distribution was observed in both composite resins, and the resin core inside the ring specimen had free flowability, leading to in greater shrinkage strain than the resin/ring interfacial region. It was observed that as the distance from the center of the resin increased, the radial average shrinkage strain decreased. The radial average shrinkage strain during light irradiation occurred to be 33% for P90 and 57% for AP-X of the entire strain at the end of the test. The shrinkage behavior of P90 and AP-X was measured to be significantly different from each other during light irradiation. In the resin near the resin/ring interface, it was confirmed that the tensile strain rapidly formed to increase after light irradiation, causing a tensile stressed, interface weak.

A Study on the Fluorescence Imaging System Packaging and Optical Intensity Characteristics (형광 이미징 시스템의 패키징 및 강도 특성 연구)

  • Kim, Taehoon;Cho, Sang Uk;Park, Chan Sik;Lee, Hak-Guen;Kim, Doo-In;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.37-41
    • /
    • 2016
  • In this paper, we introduced a near infrared fluorescence imaging system that has long working distance and analyzed on the effects of measurement variables such as gain, exposure time, working distance, magnification. Fluorescence signal intensity is growing up according to exposure time and magnification increasing, and it is getting stronger according to increase of gain, but the background signal intensity is getting stronger together. It causes low SBR. Due to a laser irradiation method, laser intensity distribution of the introduced system is not uniform and it makes fluorescence signal weak. So, we proposed a solution.

A Study on the Fabrication of p-type poly-Si Thin Film Transistor (TFT) Using Sequential Lateral Solidification(SLS) (SLS 공정을 이용한 p-type poly-Si TFT 제작에 관한 연구)

  • Lee, Yun-Jae;Park, Jeong-Ho;Kim, Dong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.229-235
    • /
    • 2002
  • This paper presents the fabrication of polycrystalline thin film transistor(TFT) using sequential lateral solidification(SLS) of amorphous silicon. The fabricated SLS TFT showed high Performance suitable for active matrix liquid crystal display(AMLCD). The SLS process involves (1) a complete melting of selected area via irradiation through a patterned mask, and (2) a precisely controlled pulse translation of the sample with respect to the mask over a distance shorter than the super lateral growth(SLG) distance so that lateral growth extended over a number of iterative steps. The SLS experiment was performed with 550$\AA$ a-Si using 308nm XeCl laser having $2\mu\textrm{m}$ width. Irradiated laser energy density is 310mJ/$\textrm{cm}^2$ and pulse duration time was 25ns. The translation distance was 0.6$\mu$m/pulse, 0.8$\mu$m/pulse respectively. As a result, a directly solidified grain was obtained. Thin film transistors (TFTs) were fabricated on the poly-Si film made by SLS process. The characteristics of fabricated SLS p -type poly-Si TFT device with 2$\mu\textrm{m}$ channel width and 2$\mu\textrm{m}$ channel length showed the mobility of 115.5$\textrm{cm}^2$/V.s, the threshold voltage of -1.78V, subthreshold slope of 0.29V/dec, $I_{off}$ current of 7$\times$10$^{-l4}$A at $V_{DS}$ =-0.1V and $I_{on}$ / $I_{off}$ ratio of 2.4$\times$10$^{7}$ at $V_{DS}$ =-0.1V. As a result, SLS TFT showed superior characteristics to conventional poly-Si TFTs with identical geometry.y.y.y.

Hemangiopericytoma Treated by Surgery with Radiation Therapy in a Dog (개의 혈관외피세포종의 수술적 및 방사선요법 치료례)

  • 홍성혁
    • Journal of Veterinary Clinics
    • /
    • v.18 no.1
    • /
    • pp.82-84
    • /
    • 2001
  • An 11 kg, 7-year-old male pug dog with lameness and tumor of the 2-3rd interdigital portion of the right forelimb was referred to the Veterinary Medical Center of the Tokyo University. On the clinical examination findings, the tumor size was $3{\times}3 cm but alopecia and necrosis were not found. On the radiological findings, a bone lysis was found in the phalanges of digit II of the right forelimb but pulmonary metastasis was not found. The mass was removed with metacarpal bone. Histopathological examination of the mass revealed highly differentiated hemangiopericytoma. Two weeks after the operation, the dog was irradiated by orthovoltage radiation. The source of irradiation was 300 kV, 4mA, 4Gy and a focal spot to skin distance of 40 cm using 1.0 Cu, 1.0Al filter. The radiation therapy was performed twice a week for 5 weeks. The dog showed no recurrence and no metastasis. It was thought that the surgery and radiation therapy treatment was quite a useful method to treat a canine heman-giopericytoma.

  • PDF