• 제목/요약/키워드: irradiation distance

검색결과 170건 처리시간 0.032초

X-선(線) 조사(照射)가 Ehrlich 암세포(癌細胞)의 용적(容積), 단백양(蛋白量) 및 수종(數種) Sulfhydryl 기(基)에 미치는 영향(影響)에 관(關)하여 (Effect of X-Irradiation on the Levels of some Sulfhydryl Groups, Protein and Cell Volume of Ehrlich Ascites Tumour Cells)

  • 유춘식;주영은
    • The Korean Journal of Physiology
    • /
    • 제3권2호
    • /
    • pp.9-16
    • /
    • 1969
  • It is well known that a number of -SH and -SS containing substances afford a certain measure of protection against radiation effects in many biological systems, and it is conceivable that inherent -SH levels in Ehrlich ascites tumour (ELD)cells may be of decisive improtance with respect to the development of cellular radiation injury. So far, little effort has been directed to elucidate the changes in levels of different -SH and -SS groups in ELD cells when the tumour-bearing whole animal was subjected to the sublethal dose of X-irradiation. The present study was designed to bring some lights in the possible changes of and relationship between various sulfhydryl levels, such as P-SH, NP-SH and NP-SS, as well as the content of protein and cell volume of ELD cells, after subjecting the ELD mice to 1,200 r of X-irradiation. The animals used in this experiment were all mixed bred mice of $20{\sim}25\;gm$ in body weight (approximately 2 months old) irrespective of sex. 12 mice in one experiment were inoculated intraperitoneally with 0.2 ml of ascites tumour cells $(2{\times}10^6\;cells)$, and on the 7th day of the tumour growth, they were X-irradiated with 1,200 r, using the conventional X-ray machine under the following conditions: 200 Kv at 15 mA, 0.5 mm Cu filter, target-skin distance: 50 cm. Radiation dose was measured with the the Philip integrating dosimeter. At 24, 36, 48 and 60 hours after the X-irradiation, the mice were killed by cervical dislocation, and the tumours were taken out. Freshly withdrawn ascites tumours were placed in ice, and immediately the cell concentration was measured with the Coulter Cell Counter (Model B), and the hematocrit of the tumour cells were also determined. Cell volume was thus calculated by the cell concentration and hematocrit value. P-SH content of ELD cells was measured potentiometrically according to the method of Calcutt & Doxey, and NP-SH and NP-SS contents were measured spectrophotometrically by the method described by Ellman. Protein content of ELD cells was determined with the Folin phenol reagent by Lowry et al. Altogether, 48 experimental mice were used, and 12 mice with the only exception of X-irradiation were used as the control. Results obtained indicate that the contents of all the cellular sulfhydryl groups as well as cell volume and protein content of the ELD cells increase significantly as time progresses after the sub-lethal X-ray dose of 1,200 r was given and that all the increase is in a lineal fashion. The regression lines of the relative values, (i. e., taking each control value as 1) of all the values obtained, and the regression lines of cell volume, protein and NP-SH are identical, whereas those of NP-SS and P-SH appear to be widely seperated. However, the difference of those two lines (NP-SS & P-SH) were found to be not significant statistically (p>0.05). Therefore, it can be concluded from the above results that all the values examined increase in a lineal fashion with no statistically significant difference among them. Also, with the radiation dose of 1,200 r, the ELD cell becomes enlarged and swollen progressively up to 60 hours post-irradiation and it becomes more than two times of the original normal size at 60 hours after the irradiation, and up to this stage, it seems apparent that the cell division has been slow due to the X-irradiation applied in this experiment. It is well understandable that the contents of NP-SH, NP-SS, P-SH and protein of the ELD cells increase in parallel with the increase of the cell volume by the X-ray does used, but it also seems interesting to note that all the cellular substances tested show no appreciable difference in the pattern of increase.

  • PDF

X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향 (Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration)

  • 박인석;이원정;정상복
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1171-1178
    • /
    • 2023
  • X선 분할조사가 식물의 생장에 미치는 영향은 아직까지 보고된 바 없어, 우리 연구에서는 X선을 새싹 보리에 분할조사 후 생장과 클로로필 농도의 변화를 알아보았다. 각 조사그룹은 대조군, 1회조사군(30 Gy 1회), 2회조사군(15 Gy 씩 2회), 3회조사군(10 Gy 씩 3회)으로 나누었고, 군당 20립 씩 사용하였다.대조군을 제외한 실험군에 대해 방사선종양학과의 선형가속기(Clinac IS, VERIAN, USA, 2011)를 이용하여 총 선량 30 Gy X선을 조사하였다. 조사 조건은 6 MV X-ray, 조사거리(Source-surface distance) 100 cm, 조사면적(field size) 18×10 cm2, 선량률(dose rate) 600 MU/min 에서 실시하였다. 분할조사는 24시간 간격으로 동일조건에서 선량만을 변경시켜 조사하였다. 보리의 생장은 종자별로 X선 조사 후 4일차 부터 1일 간격으로 9일차까지 줄기의 길이를 측정하였다. X선이 보리 싹의 엽록소 형성에 미치는 영향을 알아보기 위하여 분광광도법을 이용하여 클로로필 a 농도를 측정하였다. 통계분석은 SPSS ver. 26.0(Chicago, IL, USA)을 사용하여 분산분석(One-way ANOVA)을 실시하여 대조군(gold standard)에 대해 실험군의 줄기 길이 차이를 분석하였다(사후 검정 Dunnett T3). 발아전조사그룹에서 대조군이 실험군 보다 모든 측정일차에서 길이가 컸고, 1회조사군에서 2회조사군, 3회조사군으로 갈수록 줄기길이가 짧게 나타나 분할조사 횟수가 증가할수록 길이는 짧았다. 대조군과 1회조사군은 모든 측정일차에서 대조군의 길이가 컸지만, 통계학적인 유의한 차이를 보이지는 않았다. 발아후조사그룹에서는 대조군이 실험군 보다 모든 측정일차에서 통계학적으로 유의하게 길이가 컸고, 1회조사군에서 2회조사군, 3회조사군으로 갈수록 길이가 길게 나타나 분할조사 횟수가 증가할수록 길이도 길었다. 발아전조사그룹 보다 발아후조사그룹이 클로로필 농도가 높았고, 발아전조사그룹과 발아후조사그룹 모두 대조군에 비해 실험군에서 모두 클로로필 농도가 높았다. 또한, 분할횟수가 적을수록 클로로필 농도는 높아지는 결과를 보였다. X선의 분할조사는 새싹보리의 생장과 클로로필 농도에 영향을 미치는 것으로 나타났다.

방사선 치료실의 실내 구조와 산란선 측정에 관한 연구 (A study on the Interior Structure and Scattered Radiation Measurement of Radiotherapy Room)

  • 김민애;권용대;제재용
    • 한국방사선학회논문지
    • /
    • 제6권3호
    • /
    • pp.191-195
    • /
    • 2012
  • 연구는 방사선 치료실 내부에 알루미늄 요철 크기가 다른 구조물을 부착하여 방사선 조사 중 발생되는 산란선량을 알아보고자 한다. 알루미늄 요철구조물을 방사선 치료실 벽면에 부착하고, 방사선 조사 중 발생하는 산란선을 측정대상으로 하였다. 알루미늄 요철의 크기는 $1.5{\times}1.5$, $3{\times}3$, $5{\times}5\;cm^2$이고 크기는 가로${\times}$세로가 $60{\times}60\;cm^2$ 이다. 산란선 측정을 위한 TLD와 치료실 벽면까지의 거리는 310 cm이며 사용된 방사선 에너지는 선형가속기에서 발생되는 6MV, 15 MV 이다. 실험 결과 6 MV에서는 조사선량이 100, 300 cGy에서는 알루미늄 요철 구조물을 설치함으로써 산란선이 감소되었으나 200 cGy에서는 $5{\times}5\;cm^2$의 요철구조물에서만 산란선이 감소되었다. 15 MV에서는 조사선량이 200, 300 cGy에서는 알루미늄 요철구조물을 설치함으로써 산란선이 감소되었으나 100 cGy에서는 요철구조물에 상관없이 비슷한 결과 값을 나타내었다. 따라서 실내구조에 부가적으로 알루미늄 요철 구조물을 설치하는 것이 방사선 치료실 벽면에서 발생하는 산란선과 환자의 확률적 영향을 감소시킬 수 있는 방법이라 할 수 있다.

6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구 (Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator)

  • 이철수
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Bath-type 초음파(超音波) 세척기(洗滌器)를 이용(利用)한 태양전지모듈 접착제(接着劑) EVA(Ethylene Vinyl Acetate) 분해특성(分解特性) (Decomposition of EVA(Ethylene vinyl acetate) used as an adhesion of photovoltaic(PV) module by ultrasonic irradiation in bath-type cleaner)

  • 김영진;이재영
    • 자원리싸이클링
    • /
    • 제20권6호
    • /
    • pp.50-55
    • /
    • 2011
  • 태양전지(Photovoltaic, PV) 모듈의 층간 접착제로 사용된 EVA(Ethylene Vinyl Acetate)를 초음파 조사(irradiation)를 이용하여, 선택적으로 분해함으로써 모듈 내 실리콘웨이퍼(Si-wafer)로 제조된 셀(cell)을 분리, 회수하는 연구를 진행하였다. 본 실험에 사용한 초음파 발생장치는 bath-type의 초음파 세척기 (Output: 130 W, Frequency: 40 kHz)로, PV모듈과의 거리는 2 cm로 고정하고 유기용매 종류, 농도, 온도를 조절하면서 EVA 분해 및 셀의 분리 최적 조건을 도출하였다. $55^{\circ}C$, 5M인 조건에서는 용매 종류에 상관없이 160 min 이내에 EVA층의 완전 분해는 가능하였으나, 분해과정 중 발현되는 팽창현상(swelling)에 의해 셀의 일부분이 파손된 상태로 회수되었다. 반면에 $65^{\circ}C$, 5M조건에서는 셀의 파손이 억제된 상태로 회수 가능하였으며, 이는 온도 상승에 의해 EVA 성분의 분해속도가 상승되고, 이로 인해 EVA층의 팽창현상이 발현되기 전에 분해가 일어난 결과라고 판단된다.

방사선 조사를 받은 흰쥐 머리피부 표피층의 미세구조 (Fine Structure on the Epidermis of the Scalp of the Head-Irradiated Rats)

  • 고정식;김재호;양남길;안의태;박경호;김진국
    • Applied Microscopy
    • /
    • 제24권2호
    • /
    • pp.63-77
    • /
    • 1994
  • This experiment was performed to study the morphological responses of the epidermis of the rat scalp, following X-ray irradiation. Male rats were divided into normal and experimental groups. Rats anesthetized with sodium thiopental, were exposed only on their head areas with a single dose of 3,000rads or 6,000rads, respectively. Radiation was produced by Mitsubishi Linea Accelerator ML-4MV at the speed of 200rads/min. The target distance was 80cm. Animals were sacrificed on six hours, two days and six days following irradiation. By the perfusion fixation through the heart, rats were fixed with 1% glutaraldehyde-1% paraformaldehyde solution. Pieces of the tissue taken from the scalp were refixed in 2.5% glutaraldehyde-1.5% paraformaldehyde solution, followed by post-fixation with 1% osmium tetroxide, and embedded within araldite mixture. The sections were cut on a LKB-V ultratome, stained with uranyl acetate and lead citrate, and were observed with JEM 100CX-II electron microscope. The results were as follow; 1. Six hours after exposure to 3,000rads of X-ray. Disrupted intercellular spaces, within which some amorphous materials were filled, disrupted mitochondria, and vacuoles in the keratinocytes were frequently observed, but six days after exposure to 3,000rads of X-ray, Morphology of the keratinocytes was generally restored. 2. Many of the morphological changes were seen on the six days after exposure to 6,000rads of X-ray. 3. Widened intercellular spaces and thickened dense plaques of the desmosomes were frequently observed after exposure to 6,000rads of X-ray. 4. In the experimental groups, the Langerhans and the Merkel cells were damaged, similarly to the keratinocyte. Above results suggest that head irradiation with the dose of 3,000rads temporarily damaged the epidermis of the scalp, though most of the structures recover within six days, whereas with the dose of 6,000rads it severely damaged the epidermis without showing any recovering tendency.

  • PDF

디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동 (Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.125-132
    • /
    • 2020
  • 치과용 복합레진 Filtek P90 (3M ESPE, USA)과 Clearfil AP-X (Kuraray, Japan)를 대상으로 디지털 이미지 상관법을 이용하여 광중합 시 발생하는 수축거동을 관찰하고 등가탄성계수를 적용한 유한요소해석을 통해 시편표면의 응력분포를 산출하여 수축률분포와 비교하였다. 광조사 중과 광조사 후의 촬영 조건을 달리하여 CCD 카메라를 이용한 시편의 변형사진을 획득하고 디지털 이미지 상관분석을 하였다. DIC 분석 결과 상기의 복합레진 모두에서, 비균일한 수축변형률 분포가 관찰되었으며 링시편 내부의 레진 중심부가 자유로운 유동성으로 레진/링의 계면부보다 큰 수축 변형률이 발생하였다. 레진의 중심으로부터 거리가 멀어질수록 반경방향 평균수축률은 감소하였으며, 광조사동안에 발생한 반경방향 평균수축률은 경화시험종료(10 min) 후 발생한 반경방향 평균수축률 값을 기준으로 P90은 33%, AP-X는 57% 수준이었다. P90과 AP-X가 광조사 중의 수축거동이 크게 달랐음을 확인하였다. 레진/링의 계면부에 가까운 레진에서는 광조사 후에 인장변형률이 급격히 커져서 계면부가 인장응력을 받아 취약하게 됨을 확인하였다.

형광 이미징 시스템의 패키징 및 강도 특성 연구 (A Study on the Fluorescence Imaging System Packaging and Optical Intensity Characteristics)

  • 김태훈;조상욱;박찬식;이학근;김두인;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제23권3호
    • /
    • pp.37-41
    • /
    • 2016
  • 본 논문에서는 긴 작동거리(working distance, WD)를 가지는 근적외선 형광 이미징 시스템을 소개하고, gain, 노출시간, 작동거리, 확대배율 등 측정 변수에 의한 형광 영상의 차이에 대해 분석하였다. 노출시간이 길수록, 확대배율이 클수록 형광신호는 더욱 강해지고, gain이 클수록 형광신호도 강해지지만, 배경신호도 함께 증가하여 SBR은 나빠질 수 있다. 제안한 시스템은 레이저 조사 방식으로 인해 작동거리가 짧은 경우 레이저 조사 영역의 강도 분포가 균일하지 못해서 형광신호가 약해지며, 그에 따른 해결방안을 제안하였다.

SLS 공정을 이용한 p-type poly-Si TFT 제작에 관한 연구 (A Study on the Fabrication of p-type poly-Si Thin Film Transistor (TFT) Using Sequential Lateral Solidification(SLS))

  • 이윤재;박정호;김동환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.229-235
    • /
    • 2002
  • This paper presents the fabrication of polycrystalline thin film transistor(TFT) using sequential lateral solidification(SLS) of amorphous silicon. The fabricated SLS TFT showed high Performance suitable for active matrix liquid crystal display(AMLCD). The SLS process involves (1) a complete melting of selected area via irradiation through a patterned mask, and (2) a precisely controlled pulse translation of the sample with respect to the mask over a distance shorter than the super lateral growth(SLG) distance so that lateral growth extended over a number of iterative steps. The SLS experiment was performed with 550$\AA$ a-Si using 308nm XeCl laser having $2\mu\textrm{m}$ width. Irradiated laser energy density is 310mJ/$\textrm{cm}^2$ and pulse duration time was 25ns. The translation distance was 0.6$\mu$m/pulse, 0.8$\mu$m/pulse respectively. As a result, a directly solidified grain was obtained. Thin film transistors (TFTs) were fabricated on the poly-Si film made by SLS process. The characteristics of fabricated SLS p -type poly-Si TFT device with 2$\mu\textrm{m}$ channel width and 2$\mu\textrm{m}$ channel length showed the mobility of 115.5$\textrm{cm}^2$/V.s, the threshold voltage of -1.78V, subthreshold slope of 0.29V/dec, $I_{off}$ current of 7$\times$10$^{-l4}$A at $V_{DS}$ =-0.1V and $I_{on}$ / $I_{off}$ ratio of 2.4$\times$10$^{7}$ at $V_{DS}$ =-0.1V. As a result, SLS TFT showed superior characteristics to conventional poly-Si TFTs with identical geometry.y.y.y.

개의 혈관외피세포종의 수술적 및 방사선요법 치료례 (Hemangiopericytoma Treated by Surgery with Radiation Therapy in a Dog)

  • 홍성혁
    • 한국임상수의학회지
    • /
    • 제18권1호
    • /
    • pp.82-84
    • /
    • 2001
  • An 11 kg, 7-year-old male pug dog with lameness and tumor of the 2-3rd interdigital portion of the right forelimb was referred to the Veterinary Medical Center of the Tokyo University. On the clinical examination findings, the tumor size was $3{\times}3 cm but alopecia and necrosis were not found. On the radiological findings, a bone lysis was found in the phalanges of digit II of the right forelimb but pulmonary metastasis was not found. The mass was removed with metacarpal bone. Histopathological examination of the mass revealed highly differentiated hemangiopericytoma. Two weeks after the operation, the dog was irradiated by orthovoltage radiation. The source of irradiation was 300 kV, 4mA, 4Gy and a focal spot to skin distance of 40 cm using 1.0 Cu, 1.0Al filter. The radiation therapy was performed twice a week for 5 weeks. The dog showed no recurrence and no metastasis. It was thought that the surgery and radiation therapy treatment was quite a useful method to treat a canine heman-giopericytoma.

  • PDF