• 제목/요약/키워드: ionization chamber

검색결과 235건 처리시간 0.026초

Effects of Hyperbaric Pressure on Cellular Morphology, Proliferation and Protein Expression of Jurkat Cell

  • Oh, Eun-Ha;Oh, Sang-Nam;Im, Ho-Sub;Lee, Joo-Hyun;Kim, Jin-Young;Moon, Joo-Hee;Hong, Eun-Young;Kim, Yang-Hee;Yang, Min-Ho;Lim, Yong-Chul;Park, Sun-Young;Lee, Eun-Il;Sul, Dong-Geun
    • Molecular & Cellular Toxicology
    • /
    • 제1권2호
    • /
    • pp.116-123
    • /
    • 2005
  • The application of high pressure on cellular morphology, proliferation and protein expression of Jurkat cells (human T lymphocyte cell line) has been extensively investigated. In the present study, we manufactured a novel pressure chamber that modulates 5% $CO_{2}$, temperature and pressure (up to 3 ATA). Jurkat cells was incubated 2 ATA pressure and analyzed cellular morphology and growth using an electron microscopy and MTT assay. The cells showed the morphological changes in the cell surface, which appeared to cause a severe damage in cell membrane. The growth rate of the cells under 2 ATA pressure decreased as cultured time got increased. Furthermore, a long term exposure of high pressure on Jurkat cells may act as one of the important cellular stresses that leads to inducing cell death. Cellular proteomes were separated by 2-dimensional electrophoresis with pH 3-10 ranges of IPG Dry strips. And many proteins showed significant up-and-down expressions with hyperbaric pressure. Out of all, 10 spots were identified significantly using matrix-assisted laser desorption/ionization-time of fight (MALDI-TOF) mass spectrometry. We and found that 9 protein expressions were decreased and one protein, heat shock protein HSP 60, was increased in Jurkat cells under 2 ATA. Identified proteins were related to lipid metabolism and signal transduction.

X선 촬영시 산란선 방향 의존성에 관한 연구 (A Study on the Directional Dependence of Scatter Ray in Radiography)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.63-70
    • /
    • 1995
  • In this pauper, the back, forward, side and $45^{\circ}$ oblique scatter dose were measured the X-ray exposure conditions 60, 80, 100, 120kV, FFD 100cm, FS $20\times20cm$, toward the $25\times25cm\times10\sim20cm$ of solid water, paraffin and MiX-DP phantom, and Pb, Cu, Al, and styrofoam meterials, by the electrometer and 5.3 cc ionization chamber. The obtained results are summarized as following. 1. The percentage depth dose(PDD) at the range of the diagnostic x-ray energy were appeared 50 % depth dose at the 2 cm depth with 60 kV, and 5 cm depth with 120 kV X-ray, 10 % depth dose at the 10 cm depth with 60 kV and 14 cm depth with 120 kV X-ray, 5 % below depth dose at the 20 cm depth. 2. The back scatter dose which were generated the surface of Pb, Cu and Al metal plates were 10 % below, and than the back scatter dose at the Pb plate were a most amount of these which were about 10 %, and were appeared the order of Cu and Al. 3. The percentage forward scatter were appeared from 50 % to 65 %, and the more phantom thicknees become, the more forward scatter were increased with the ratio of 5 % per 5 cm thickness. 4. The percentage back scatter which were generated the tissue equivalence meterials solid water, paraffin and MiX-DP were from 20 % to 40 %, and than the back scatter dose at the solid water were a mest amount of those, and paraffin and MiX-DP were appeared with the next values. 5. The percentage $90^{\circ}$ lateral and $45^{\circ}$ oblique side scatter dose were measured from 4 % to 12 %. a most amount of scatter dose which were generated from the patient in radiography were the forward scatter, the next values were the back scatter, the third values were the $90^{\circ}$ lateral scatter.

  • PDF

Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정 (High Energy Electron Dosimetry by Alanine/ESR Spectroscopy)

  • 추성실
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.85-92
    • /
    • 1989
  • 물질에 방사선을 조사시키면 구성원자 또는 분자의 일부분이 전리되며 특수한 유기화합물은 장기간 free radical상태로 존재하고 그 밀도는 조사된 방사선량에 비례한다. Free radical상태의 물질에 마이크로파와 같은 전자파를 투과시키면 free radicl된 전자의 고유진동과 일치된 전자파를 흡수하는 전자스핀공명(Electron Spin Resonance)이 일어나며 흡수된 전파의 강도를 측정함으로서 조사된 방사선량을 추측할 수 있다. ESR를 이용한 free radical dosimeter로서 가장 잘 알려진 물질이 아미노산 alanine이므로 이것과 파라핀 $10\%$를 혼합하여 $0.4\times1cm$의 alanine dosimeter를 제작하였다. 측정 방법은 방사선 흡수선량을 직접 측정할 수 있도록 조직등가인 물 팬텀과 방수된 Alanine dosimeter holder를 제작하고 의료용 선형가속기에서 발생되는 $6\~21$ MeV전자선을 조사하면서 최대 흡수 선량과 깊이에 따른 선량분포를 측정하였다. 전자선 조사선량은 1 Gy에 60 Gy까지의 방사선 치료선량 범위를 선택하였으며 측정결과 전자선량 증가에 따라 ESR신호의 진폭이 선형비례적으로 증가하였다. 그러나 전자선량이 4 Gy이하에서는 alanine dosimeter의 선량 균일성 이 $\pm2\~4\%$ (표준편차)의 오차가 있었으며 4 Gy이상에서는 $\pm1\%$ 이하의 오차를 나타냄으로서 환자에 대한 전자선 조사량 범위인 1Gy에서 60Gy까지의 흡수선량을 정확히 측정할 수 있었다. 측정한 결과 전자선 에너지 12 MeV이하에서는 전리상으로 측정 계산된 선량과 일치하였지만 15 MeV이상에서는 표면에서 깊이 2cm까지의 흡수선량이 약$2\~5\%$가 높았다. 이와 같은 현상은 의료용 선형가속기의 전자선 방출구에 장착된 산란판과 조사면을 조정하는 cone에 의하여 발생되는 저 에너지 산란전자선이 alanine dosimeter에 측정된 것으로서 에너지가 증가될수록 오염 정도가 증가되었다. 본 실험을 통하여 지금까지 고에너지 전자선량계측에서 전리상에 의한 전기량 측정과 산란선이 없는 단일 에너지로만 간주하여 계산하였던 전자선 흡수선량 측정방법을 직접 흡수선량 측정이 가능한 Alanine/ESR dosimetry로서 교정하는 것이 바람직하다고 생각한다.

  • PDF

광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정 (Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs))

  • 임인철;유윤식;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.86-92
    • /
    • 2011
  • 본 연구는 최근 생체내선량측정에서 유용성을 재평가 받고 있는 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)와 다이오드 검출기를 병행하여 직장암 방사선치료 환자의 피부선량을 측정하고 치료계획시스템 에서 계산 선량과 측정 선량을 비교하여 OSL 선량계의 임상적 유용성을 평가하고자 하였다. 각 OSL 선량계의 고유한 교정상수를 측정하고 10 명의 직장암 환자를 대상으로 3 부위를 설정하여 측정하였다. 기준 흡수선량 100 cGy에 대하여 OSL 선량계의 교정상수는 6 MV X-선의 경우 1.17, 10 MV X-선의 경우 1.28 이었다. 또한 직장암 환자들의 피부선량은 측정 부위별로 치료계획시스템에서 계산 선량과 비교하여 다이오드 검출기는 1.16 ~ 2.83%의 선량증가를 보였고 OSL 선량계는 1.36 ~ 2.17%의 선량증가를 보였다. 특히 피부면의 굴곡이 심한 회음부(perineum)에서 계산된 선량과 전달 선량간 차이가 증가되었으며 다이오드 검출기보다 OSL 선량계가 측정값의 변화가 상대적으로 작았다. 따라서 OSL 선량계는 기존에 사용하던 이온함 및 다이오드 검출기를 대신하여 방사선량학적 오차의 검증 및 생체내선량측정에서 임상적으로 적용이 가능하였으며 직장암 환자의 굴곡이 심한 회음부 주변의 선량 평가에 대한 연구가 계속되어야 할 것으로 판단된다.

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성 (Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy)

  • 강민규;김성준;신현수;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.218-222
    • /
    • 2010
  • 세기조절방사선치료(intensity modulated radiation therapy, IMRT)는 치료면적을 소조사면으로 나누어 여러 방향에서 방사선이 조사되기 때문에 기존의 치료방법에 비해 많은 MU와 더 긴 치료시간이 요구된다. 통증 및 장애 등으로 인해 장시간 같은 자세를 유지하기 어려운 환자의 경우, 효과적인 치료를 위해서는 선량율을 증가시켜 치료시간을 줄이는 것이 한 방법이다. 본 연구에서는 선량율 변화에 따른 선량 및 선량분포를 측정하고 그 변화를 알아보았다. IMRT 치료계획은 ECLIPSE 시스템(Varian, SomaVision 6.5, USA)을 이용하여, $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ 방향의 5문 조사로 계획하였다. 선량율 변화에 따른 선량 및 선량분포 확인을 위해 선량율은 100, 300, 500 MU/min으로 설정하였으며, 선량과 선량분포는 이온함(PTW, TN31014)과 필름(EDR2, Kodak)을 이용하여 각각 측정하였다. 이때 필름 선량계는 아크릴 팬톰에 삽입 후 빔의 조사방향과 나란하게 설치되었고 방사선조사를 위한 선형가속기는 21EX-S (Varian, USA)를 이용하였다. 측정된 필름 선량계는 VXR-16 (Vidar System Corporation)을 이용하여 분석함으로써 선량분포를 확인하였다. 선량율이 증가할수록 CTV를 포함하는 100% 선량분포의 면적이 거의 선형적으로 감소함을 보였다.

자기장 내에서 전자선의 표면선량 변화 측정 (Surface Dose Measurement of Electron Beam within the Magnetic Field Variation)

  • 제재용;노경석;신운재;박철우
    • 대한방사선치료학회지
    • /
    • 제20권2호
    • /
    • pp.103-107
    • /
    • 2008
  • 목적: 전자선 조사야에서 자기장의 유무, 세기와 형태에 따른 표면 선량의 변화를 알아보고 임상에서의 적용 가능성에 대하여 알아보고자 한다. 대상 및 방법: 6 MeV 전자선과 $10{\times}10\;cm^2$의 조사야를 이용하여 9개의 hole이 있는 차폐블록을 제작하여 필름 농도를 측정하고 전자선 조사야 내에 자장이 위치 할 때와 조사야의 외부에 위치 할 때의 선량변화를 필름과 표면선량 측정기를 이용하여 측정하였다. 결 과: 전자선의 입사각은 조사야의 중심에서 측면으로 4 cm 지점에서 3도 정도의 입사각을 나타내었으며, ring type의 자기장을 사용할 경우 0.9%의 표면선량 증가가 나타나고, lens block에 자기장을 위치시키면 1.58%의 표면선량이 증가하고, half 조사야의 중심 측면에 자기장을 위치시키면 조사야의 중심에 3.6%의 표면 선량 증가를 보였다. 결 론: 전자선은 선속의 중심에서 측면으로 일정 각도를 이루고 조사되어지며 자기장이 위치한 조사야내 표면선량의 변화는 자기장으로 인하여 전자선의 진행 방향이 변화되었음을 의미하고 안구와 같은 부위에 환자의 불편함이 없이 표면선량을 증가 시켜야 할 경우 유용한 방법으로 사용되어질 것이다.

  • PDF

전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구 (Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment)

  • 양승우;한무재;신요한;정재훈;최윤선;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2020
  • 본 연구에서는 전자선 치료에서 전자선 선량 측정 시 교차교정이 필요한 기존 평행평판형이온함을 대체하고자 하였다. 광도전성 반도체 화합물 HgI2를 사용하여 선량계로 제작하였으며, 선형가속기에서 6, 9, 12 MeV 전자선에 대한 HgI2 선량계의 특성을 분석하였다. 그리고 기존 선량계와의 대체가능성과 전자선 선량계로서의 적용 가능성을 평가하고 전자선 선량계 개발의 기초연구로써 활용하고자 하였다. 재현성 평가결과, RSD는 6, 9, 12 MeV 에너지에서 각각 0.4246%, 0.5054%, 0.8640%로 나타나 출력 신호가 안정적인 것을 나타내었다. 선형성 평가결과, 직선형 추세선의 신뢰도 지표 R2값은 6 MeV에서 0.9999, 9 MeV에서 0.9996, 12 MeV에서 0.9997로 나타나 선량이 증가함에 따라 HgI2에 출력 신호가 비례한 것을 확인할 수 있었다. 본 연구의 HgI2 선량계는 전자선 측정 적용가능성이 매우 높은 것으로 판단되며, 전자선 검출에 대한 기초연구로 활용될 수 있을 것으로 사료된다.

갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가 (Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients)

  • 임상무;우광선;정위섭;홍성운;김장휘;김기섭
    • 대한핵의학회지
    • /
    • 제29권1호
    • /
    • pp.54-60
    • /
    • 1995
  • 방사성 핵종의 체내 투여 또는 체내 오염에 의한 내부피폭 흡수선량 측정을 위하여 개발된 MIRD 씨스템을 이용하여 175mCi $^{131}I$ 치료를 받는 8명의 분화된 갑상선암의 주변림프절 전이 환자에서 전신, 위, 신장, 방광 및 골수 등의 흡수선랑을 측정하였다. 전리함 검출기와 자료저장 장치가 부착된 Eberline Smart 200 씨스템을 이용하여 전신 $^{131}I$의 시간 방사능 곡선을 얻었고, 선형 회귀분석을 하여 곡선하면적을 구한 값을 투여 방사능량(Ao)으로 나누어 체류시간($\tau$)으로 하였다. MIRDose2의 S값을 이용하여 전신흡수선량을 구하였으며 ICRP publication 53의 표준인 신장, 방광, 위의 체류시간을 이용하여, 이들 장기의 흡수선량을 구하였다. 전신 및 골수의 흡수선량은 22.4 및 25.4rad로 ICRP 최대허용선량보다 훨씬 낮았으며, 방광에 375.1, 위에 285.1rad로 심각한 증상을 초래할 정도의 선량은 아니었다. 분화된 갑상선암의 폐 및 뼈전이 환자에서 200mCi 이상 투여방사능량을 증가시킬 경우 이 방법으로 전신 및 골수 등의 흡수 선량을 평가하여 안전성을 확인할 수 있을 것으로 생각된다.

  • PDF

전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화 (Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure)

  • 석진우;;한성;백영환;고석근;윤기현
    • 한국세라믹학회지
    • /
    • 제40권10호
    • /
    • pp.967-972
    • /
    • 2003
  • 직경 5 cm cold hollow cathode 이온원을 박막의 이온보조증착법 또는 이온보조반응법에 사용하기에 적합한 이온빔으로 넓은 면적을 균일하게 조사할 수 있는 이온원을 설계, 제작하기 위한 방안으로 연구하게 되었다. 이온원은 글로우 방전을 위한 음극과 이온화 효율의 증가를 위한 자석, 플라즈마 챔버, 그리드 전극으로 이루어진 이온광학시스템, 직류전원공급장치로 이루어진다. 전자인출전극의 구조 및 형태로 구분하여 한개의 노즐로 이루어진 (I) 형태와 복수개의 노즐로 변형된 (II) 형태로 제작하였다. 서로 다른 구조의 전자인출전극 (I)형태와 (II) 형태를 부착한 이온원에 beam profile을 측정한 결과 (I) 형태의 전자인출전극을 부착한 경우에는 이온원의 중심에서 140 $\mu\textrm{A}$/$\textrm{cm}^2$으로 측정되어 졌으며, 외곽으로 멀어질수록 급격히 전류밀도가 감소하여 균일한 영역(최대값의 90%)은 직경 5 cm로 측정되어졌다. (II) 형태로 변형되어진 이온원의 경우 중심에서 65 $\mu\textrm{A}$/$\textrm{cm}^2$으로 (I) 형태와 비교하여 상대적으로 낮은 전류밀도가 측정되었지만 외각으로 멀어졌을 경우에도 전류밀도는 완만하게 감소하여 균일한 영역은 직경 20 cm로 측정되었으며, 본 연구목적에 부합되는 특성이 측정되었다. 이온빔 균일도가 증가한 (II) 형태의 전자인출전극을 부착한 이온원으로 주입하는 아르곤 가스량의 변화, 이온광학시스템의 플라즈마 그리드 전극과 가속 그리드 전극 간격의 조절, 이온빔 에너지 변화에 따른 beam profile 및 특성을 괸찰하였다.