• Title/Summary/Keyword: ionic species

Search Result 280, Processing Time 0.022 seconds

Electrochemical properties of gel copolymer- electrolyte based on Phosphonium ionic liquid

  • Cha, E.H.;Lim, S.A.;Park, J.H.;Kim, D.W.;Park, J.H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.4
    • /
    • pp.304-308
    • /
    • 2008
  • Noble Poly (lithium 2-acrylamido-2-methyl propane sulfonate) and its copolymer with N-vinyl formamide based on trihexyl (tetradecyl) phosphonium acetate [$(C_6H_{13})_3$ P ($C_{14}H_{29}$) $CH_3COO$; $P_{66614}$ $CH_3COO$] and trihexyl (tetradecyl)phosphonium bis(trifluoromethane sulfonyl) amide ([$(C_6H_{13})_3P(C_{14}H_{29})$] [TFSA];$P_{66614}TFSA$) were prepared and analyzed to determine their characteristics and properties. The ionic conductivity of a copolymer based $P_{66614}TFSA$ ionic liquid system exhibits a higher conductivity ($8.9{\times}10^{-5}Scm^{-1}$) than that of a copolymer based $P_{66614}CH_3COO$ system ($1.57{\times}10^{-5}Scm^{-1})$. The charge on the TFSA anion is spread very diffusely through the S-N-S core and particularly in the trifluoromethane groups, and this diffusion results in a decreased interaction between the cation and the anion. The viscosity of $P_{66614}TFSA$ (39 cP at 343 K) and $P_{66614}CH_3COO$ (124 cP at 343 K), which is very hydrophobic, was fairly high. High viscosity leads to a slow rate of diffusion of redox species. The ionic conductivity of copolymer of a phosphonium ionic liquid system also exhibits higher conductivity than that of a homopolymer system. Phosphonium ionic liquids were thermally stable at temperatures up to $400^{\circ}C$.

Radon and TSP Concentrations in the Ambient Air of Gosan Area, Jeiu Island between 2001 and 2004 (제주도 고산지역의 라돈 및 TSP 에어로졸 농도 특성: 2001~2004년 측정)

  • Kang, Chang-Hee;Ko, Hee-Jung;Zahorowski, Wlodek
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.612-624
    • /
    • 2007
  • The real-time monitoring of radon ($^{222}Rn$) concentrations has been carried out to evaluate its ambient background concentration levels in Gosan site, Jeju Island between January 2001 and December 2004. In addition, the atmospheric TSP aerosols have been sampled, and their ionic and metallic components were analyzed to understand the characteristics of air pollution. The mean concentration of radon was $3,121{\pm}1,627\;mBq/m^3$, and the seasonal mean concentrations for spring, summer, fall and winter seasons were 2,898, 2,398, 3,571 and $3,646\;mBq/m^3$, respectively, The hourly concentrations have shown the highest value at 7 a.m. and the lowest value at 2 p.m. From the backward trajectory analyses, the radon concentrations have increased, when the air parcels were moved from the Chinese continent to Jeju area. On the other hand, they have decreased, when the air parcels from the North Pacific Ocean. In the analytical results of ionic species and metal elements of TSP aerosols, the concentrations of $nss-{SO_4}^{2-}$ and S were higher in June and March. Meanwhile, the concentrations of other anthropogenic species as well as soil components were mostly higher in March and April. On the basis of factor analysis, the TSP aerosols at Gosan area were largely influenced by soil sources, followed by anthropogenic sources and marine sources. From the result of backward trajectory analyses, the concentrations of $nss-{SO_4}^{2-},\;{NO_3}^-$, Al and Ca were mostly higher, when the air parcels moved from Chinese continent to Jeju area. On the other hand, their concentrations were lower, when the air parcels drifted from the North Pacific Ocean.

Pollution Characteristics of Rainwater at Jeju Island during 2009~2010 (2009~2010년 제주지역 강우의 오염 특성 연구)

  • Kim, Ki-Ju;Bu, Jun-Oh;Kim, Won-Hyung;Lee, Yoon-Sang;Hyeon, Dong-Rim;Kang, Chang-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.818-829
    • /
    • 2013
  • The collection of rainwater samples was made at Jeju area during 2009~2010, and the major ionic species were analyzed. In the comparison of ion balance, conductivity, and acid fraction for the validation of analytical data, the correlation coefficients showed a good linear relationship within the range of 0.966~0.990. The volume-weighted mean pH and electric conductivity were 4.9 and $17.8{\mu}S/cm$, respectively, at the Jeju area. The volume-weighted mean concentrations of ionic species in rainwater were in the order of $Cl^-$ > $Na^+$ > $nss-SO_4{^{2-}}$ > $NH_4{^+}$ > $NO_3{^-}$ > $Mg^{2+}$ > $H^+$ > $nss-Ca^{2+}$ > $HCOO^-$ > $K^+$ > $PO_4{^{3-}}$ > $CH_3COO^-$ > $NO_2{^-}$ > $F^-$ > $HCO_3{^-}$ > $CH_3SO_3{^-}$. The ionic strength of rainwater was $0.26{\pm}0.21$ mM during the study period. The composition ratios of ionic species were such as 50.1% for the marine sources ($Na^+$, $Mg^{2+}$, $Cl^-$), 30.9% for the anthropogenic sources ($NH_4{^+}$, $nss-SO_4{^{2-}}$, $NO_3{^-}$), and 4.7% for the soil source ($nss-Ca^{2+}$), and 3.1% for organic acids ($HCOO^-$, $CH_3COO^-$). From the seasonal comparison, the concentrations of $NO_3{^-}$, $nss-Ca^{2+}$, and $nss-SO_4{^{2-}}$ increased in winter and spring seasons, indicating a reasonable possibility of long range transport from Asia continent. Especially, the acidifying contributions by major inorganic acids ($nss-SO_4{^{2-}}$ and $NO_3{^-}$) and organic acids ($HCOO^-$ and $CH_3COO^-$) were 87.6% and 12.4%, respectively. In comparison by sectional inflow pathway of air mass during the rainy sampling days, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ were relatively high when the air mass was moved from the China continent into Jeju area.

Unsteady Electroosmotic Channel Flows with the Nonoverlapped and Overlapped Electric Double Layers

  • Kang, Sang-Mo;Suh, Yong-Kweon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2250-2264
    • /
    • 2006
  • In micro- and nanoflows, the Boltzmann distribution is valid only when the electric double layers (EDL's) are not overlapped and the ionic distributions establish an equilibrium state. The present study has numerically investigated unsteady two-dimensional fully-developed electroosmotic flows between two parallel flat plates in the nonoverlapped and overlapped EDL cases, without any assumption of the Boltzmann distribution. For the study, two kinds of unsteady flows are considered: one is the impulsive application of a constant electric field and the other is the application of a sinusoidally oscillating electric field. For the numerical simulations, the ionic-species and electric-field equations as well as the continuity and momentum ones are solved. Numerical simulations are successful in accurately predicting unsteady electroosmotic flows and ionic distributions. Results show that the nonoverlapped and overlapped cases are totally different in their basic characteristics. This study would contribute to further understanding unsteady electroosmotic flows in micro- and nanofluidic devices.

Study on the Characteristics of Concentrations and Compositions in $PM_{10}$ in Kunsan City (군산 지역에서 $PM_{10}$의 농도 및 성분 특성에 관한 연구)

  • 김성천;송재종;임성호;강달선
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.18-24
    • /
    • 2000
  • The collection of PM10 samples were collected by a PM10 hi-vol. air sampler from June, 1998 through May, 1999 in Kunsan located at western coastal region of Korea. We obtained 84 samples during sampling period. Samples were analyzed to quantify the concentration of ionic and metallic components such as SO42-, NO3-, Cl-, NH4+, K+, Na+, Mg2+, Zn, Cd, Cr, Pb and Fe. Seasonal variations of the concentrations by wind directions of each component were studied. We found that PM10 concentration had the highest level in winter and the lowest level in summer. When the wind direction is from west to east, the concentration of most ionic and metallic species were higher compared to reverse direction. That implied the effect of air pollutants from industrial area. Also, substantial amount of Na+ and Cl- were observed, which was assumed to the effect from the sea.

  • PDF

Conduction Mechanism of Charge Carriers in Electrodes and Design Factors for the Improvement of Charge Conduction in Li-ion Batteries

  • Akhtar, Sophia;Lee, Wontae;Kim, Minji;Park, Min-Sik;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-20
    • /
    • 2021
  • In-depth knowledge of electrode processes is crucial for determining the electrochemical performance of lithium-ion batteries (LIBs). In particular, the conduction mechanisms of charged species in the electrodes, such as lithium ions (Li+) and electrons, are directly correlated with the performance of the battery because the overall reaction is dependent on the charge transport behavior in the electrodes. Therefore, it is necessary to understand the different electrochemical processes occurring in electrodes in order to elucidate the charge conduction phenomenon. Thus, it is essential to conduct fundamental studies on electrochemical processes to resolve the technical challenges and issues arising during the ionic and electronic conduction. Furthermore, it is also necessary to understand the transport of charged species as well as the predominant factors affecting their transport in electrodes. Based on such in-depth studies, potential approaches can be introduced to enhance the mobility of charged entities, thereby achieving superior battery performances. A clear understanding of the conduction mechanism inside electrodes can help overcome challenges associated with the rapid movement of charged species and provide a practical guideline for the development of advanced materials suitable for high-performance LIBs.

Uncertainties of ionic species in snowpit samples determined with ion chromatography system (이온크로마토그래피 시스템을 이용한 눈 시료의 이온성분 측정자료의 불확도 산출)

  • Hong, Sang-Bum;Hur, Soon-Do;Kim, Sun-Mee;Hong, Sungmin;Chung, Ji-Woong;Kang, Namgoo;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.350-363
    • /
    • 2012
  • To determine ionic species in snowpit samples using ion chromatography system, we described the performance of ion chromatography(IC) system, cleaning method of bottle, and interference by filtering procedure. The limit of detection, reproducibilities, and accuracies determined with BCR$^{(R)}$-408 were 0.01-0.26 ${\mu}g$/L, 0.4-17.4%, 4.5-12.0% for cations and 0.02-0.26 ${\mu}g/L$, 0.1-27.6%, 1.3-5.6% for anions, respectively. Lab blank test for sample bottle indicated that $CH_3CO_2{^-}$, $HCO_2{^-}$, and $NH_4{^+}$ can be easily contaminated in the lab environment. The positive interferences of $NO_3{^-}$ were partly attributed to the cleaning method of bottle. The filtering of melted snow sample should be carefully applied because it can positively affect the concentration levels of some ionic species. Finally, this method was applied to measure ionic species in snowpit samples from the upward area near NEEM camp and the uncertainties of measurement data of $F^-$ were also estimated.

Comparison of Water Relations of Three Cultivated Pleurotus Species and Trichoderma Green Moulds

  • Lee, Hyang-Burm;Naresh Magan;Yu, Seung-Hun
    • The Plant Pathology Journal
    • /
    • v.16 no.1
    • /
    • pp.25-28
    • /
    • 2000
  • The effect of ionic osmotic potential (Ψ$\pi$), and matric potential (Ψm) in the range of -0.2 to -4.0 Mpa on mycelial growth of three species of Pleurotus (P.florida, P.ostrenatus and P.safor-caju) were determined over a range of temperature (15-3$0^{\circ}C$) on a 2% malt extract agar medium and compared with the Ψ$\pi$ effect on growth of two strains of Trichoderma green mould. With the ionic solute KCl, optimun Ψ$\pi$for growth was -0.2 MPa for P.floreda and in the range of -0.2 to -0.5 MPa, with slight growth at -3.0 MPa and with nogrowth at -4.0 MPa. Of the species of Pleurotus, P.florida grew signigicantly slower than the other two species. Growt of the species of Pleurocus was significantly slower when water potential (Ψ$\omega$) was modified matrically with polyethylene glycol (PEG) 8000 then osmotically with KCl. They were also more sensitive to changes in Ψm than Ψ$\pi$The optimum Ψm of the Pleurotus was -0.5 Ψm, with no growth below -3.0 MPa. Of the species of Pleurotus, P.florida was most sensitive and P.sajor-caju was more tolerent to lowered Ψ$\pi$,but P.sajor-caju was most sensitive to lowered Ψm. The growth rate of the Trichoderma green mould strains was much faster than that observed for the Pleurotus spp. Optimum growth for bot strains of Trichoderma was in the range of -0.2 to -0.5 MPa. Strain CNU 503 was more tolerant to water stress than strain CNU 501. Both strains were able to grow up to 30% of optimum growth at -4.0 MPa at 25-3$0^{\circ}C$.

  • PDF

Ionic Equilibria Analysis of $NiCl_2$ in Chloride Solutions by Using Bromley Equation (염산용액에서 Bromley식을 이용한 염화니켈의 이온평형해석)

  • Lee Man-Seung;Lee Gwang-Seop
    • Resources Recycling
    • /
    • v.12 no.3
    • /
    • pp.38-45
    • /
    • 2003
  • ionic equilbria of nickel chloride in hydrochloric acid solutions were analyzed by considering chemical equilibria, mass and charge balance equations. The activity coefficients of solutes were calculated by using Bromley equation. It was found that most of species containing nickel existed as $Ni^{2+}$$NiCl^{+}$. The mole fractions of nickel hydroxides were very low in the con-centration ranges considered in this study and the mole fraction of$Ni_4$ $(OH)_{4}^{4+}$ increased greatly with the pH of the solution. The pH values of $NiCl_2$ $-HCl-NaOH-H_2$O system at $25^{\circ}C$ calculated in this study agreed well with those experimentally measured up to ionic strength of 9.4m.

Comparison of Chemical Compositions of Size-segregated Atmospheric Aerosols between Asian Dust and Non-Asian Dust Periods at Background Area of Korea

  • Kim, Won-Hyung;Song, Jung-Min;Ko, Hee-Jung;Kim, Jin Seog;Lee, Joung Hae;Kang, Chang-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3651-3656
    • /
    • 2012
  • The size-segregated atmospheric aerosols have been collected at 1100 m site of Mt. Halla in Jeju, a background area in Korea, using 8-stage cascade impact air sampler during Asian dust and non-Asian dust storm periods. Their ionic and elemental species were analyzed, in order to examine the pollution characteristics and composition change between Asian dust and non-Asian dust periods. The major ionic species such as nss-$SO_4{^{2-}}$, $NH_4{^+}$, and $K^+$ were predominantly distributed in the fine particles (below $2.1{\mu}m$ diameter), and besides the $NO_3{^-}$ was distributed more in coarse particle fraction than fine particle. On the other hand, the typical soil and marine species i.e., nss-$Ca^{2+}$, $Na^+$, $Cl^-$, and $Mg^{2+}$, were mostly existed in the coarse particles (over $2.1{\mu}m$ diameter). As well in the elemental analysis of aerosols, the major soil-originated Al, Fe, Ca, and others showed prominently high concentrations in the coarse particle fraction, whereas the anthropogenic S and Pb were relatively high in the fine particle fraction. From the comparison of aerosol compositions between Asian dust and non-Asian dust periods, the concentrations of the soil-originated species such as nss-$Ca^{2+}$, Al, Ca, Fe, Ti, Mn, Ba, Sr have increased as 2.7-4.2 times during the Asian dust periods. Meanwhile the concentrations of nss-$SO_4{^{2-}}$ and $NO_3{^-}$ have increased as 1.4 and 2.0 times, and on the contrary $NH_4{^+}$ concentrations have a little bit decreased during the Asian dust periods. Especially the concentrations of both soil-originated ionic and elemental species increased noticeably in the coarse particle mode during the dust storm periods.