Compatibility of Lithium ion Phosphate Battery in Solar off Grid Application

  • Lakshmanan, Sathishkumar;Vetrivel, Dhanapal;Subban, Ravi;R., Saratha;Nanjan, Sugumaran
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.472-478
    • /
    • 2022
  • Solar energy harvesting is practiced by various nations for the purpose of energy security and environment preservation in order to reduce overdependence on oil. Converting solar energy into electrical energy through Photovoltaic (PV) module can take place either in on-grid or off-grid applications. In recent time Lithium battery is exhibiting its presence in on-grid applications but its role in off-grid application is rarely discussed in the literature. The preliminary capacity and Peukert's study indicated that the battery quality is good and can be subjected for life cycle test. The capacity of the battery was 10.82 Ah at 1 A discharge current and the slope of 1.0117 in the Peukert's study indicated the reaction is very fast and independent on rate of discharge. In this study Lithium Iron Phosphate battery (LFP) after initial characterization was subjected to life cycle test which is specific to solar off-grid application as defined in IEC standard. The battery has delivered just 6 endurance units at room temperature before its capacity reached 75% of rated value. The low life of LFP battery in off-grid application is discussed based on State of Charge (SOC) operating window. The battery was operated both in high and low SOC's in off-grid application and both are detrimental to life of lithium battery. High SOC operation resulted in cell-to-cell variation and low SOC operation resulted in lithium plating on negative electrode. It is suggested that to make it more suitable for off-grid applications the battery by default has to be overdesigned by nearly 40% of its rated capacity.

납 표준물질을 이용한 방사성동위원소 Thallium-201의 화학적 분리공정 개발 (Development of Chemical Separation Process for Thallium-201 Radioisotope with Lead Standard Material)

  • 이준영;김태현;박정훈
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.543-549
    • /
    • 2023
  • Thallium-201 (201Tl) is a medical radioisotope which emits gamma rays when it decays and used in myocardial perfusion scans in single-photon emission tomography due to its similar properties to potassium. Currently, the Korea Institute of Radiological & Medical Sciences is the only institution producing 201Tl in Korea, and optimization of 201Tl production research is necessary to meet supply compared to domestic demand. To this end, technical analysis of plating target production and chemical separation methods essential for 201Tl production research is conducted. It deals with the process of generating and separating 201Tl radioisotope and target production, It can be generated through a nuclear reaction such as natHg(p,xn)201Tl, 201Hg(p,n)201Tl, natPb(p,xn)201Bi → 201Pb → 201Tl, 205Tl(p,5n)201Pb → 201Tl, and considering impure nuclide generated simultaneously with the use of proton beam energy of 35 MeV or less, it is intended to be produced using the 203Tl(p,3n)201Pb→201Tl nuclear reaction. In particular, the chemical separation of Tl is a very important element, and the chemical separation methods that can separate it is broadly divided into four types, including solid phase extraction, liquid-liquid, electrochemical, and ion exchange membrane separation. Some chemical separations require additional separation steps, such as methods using selective adsorption. Therefore, this technical report describes four chemical separation methods and seeks to separate high-purity 201Tl using a method without additional separation steps

초고속 증착용 마그네트론원 설계 및 특성에 관한 연구 (A study on magnetron source design and characteristics for super high rate deposition)

  • 빈진호;남경훈;한전건
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 춘계학술발표회 초록집
    • /
    • pp.8-8
    • /
    • 2001
  • 초고속 증착은 짧은 시간에 박막 형성을 가능하게 하므로 window glass 코팅등의 대면적 코팅에 있어서 비용을 절감 시키고, 대량생산을 가능하게 만들기 때문에 관심이 집중되고 있다. 고속증착 공정으로는 high current arc, laser arc, hollow cathode discharge ion plating 그리고 마그네트론 스퍼터링법 등이 있다. 특별히 마그네트론 스퍼터링법은 3m이상의 넓이에 코팅을 할때 두께가 매우 균일하며, 증착율은 evaporation 공정에 비해 경제적, 기능적인 면에서 효율적이다. 그리고 증착된 박막은 매우 조밀하고 좋은 밀착력을 갖고 있으며, 고융점 금속을 포함하여 금속 합금 및 혼합물의 비율을 조정 및 금속 산화물, 질화물, 탄화물 등과 같은 금속의 증착도 stoichiometry를 조정하여 박막을 합성 시키는데 있어서 효과적이다. 이러한 초고속 증착을 만들기 위한 마그네트론 스퍼터링법의 요건은 마그네트론 원이 높은 타켓 power density를 가져야 하며, 타켓에서 효율적으로 플라즈마를 구속하여 스퍼터 되는 이온의 양을 최대화 시킬 수 있어 한다. 따라서 본 실험에서는 초고속 증착을 위해서 직경 50mm 타켓의 UBM magnetron원을 설계 제작하였다. 고밀도의 플라즈마를 형성시키기 위해서, Poisson simulation c code를 이용하여 자기장의 방향, 세기 및 밀도를 측정 하였고, 자기장 측정기(Gauss meter)를 이용하여 실제 자장을 측정 비교 분석하였다. 상기의 data를 바탕으로 여러 형상의 마그네트론원을 설계, 제작하였고. 마그네트론 원의 특성 분석을 위해 I-V 방전 특성을 평가하였고 substrate ion current density와 박막의 증착율을 측정하였다.duty-on 시간의 증가에 따라 $Cr_2N$ 상의 형성이 점점 많아져 80% duty-on 시간 경우에는 거의 CrN과 $Cr_2N$ 상이 공존하는 것으로 나타났다. 또한 duty-on 시간이 증가할수록 회절피크의 세기가 증가하여 결정화가 더 많이 진행되어짐을 알 수 있었다. 마찬가지로 바이어스 펄스이 주파수에 다른 결정성의 변화도 펄스의 주파수가 증가할수록 박막이 결정성이 좋아지고 $Cr_2N$ 상이 쉽게 형성되었다. 증착 진공도에 따른 결정성은 상대적으로 질소의 농도가 높은 낮은 진공도에서는 CrN 상이 주로 형성되었으며, 반대로 높은 진공도에서는 $Cr_2N$ 상이 많이 만들어졌다. 즉 $1.3{\times}10^{-2}Torr$의 증착 진공도에서는 CrN 상만이 보이는 반면 $9.0{\tiems}1-^{-2}Torr$ 진공도에서부터 $Cr_2N$ 상이 형성되기 시작하여 $5.0{\tiems}10^{-2}Torr$ 진공도에서는 두개의 상이 혼재되어 있음을 알 수 있었다. 박막의 내마모성을 조사한 결과 CrN 박막의 마찰 계수는 초기에 급격하게 증가한 후 0.5에서 0.6 사이의 값으로 큰 변화를 보이지 않았으며, $Cr_2N$ 박막도 비슷한 거동을 보였다.차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$

  • PDF

전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구 (Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire)

  • 이계형;조진형;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권2호
    • /
    • pp.127-136
    • /
    • 2005
  • 광도 차이를 보이지 않았지만 전기도금한 선재 (p<0.001). 스테인레스스틸 선재 (p <0.05). 구리 (p<0.001) 는 배지만을 첨가한 경우보다 통계적으로 유의한 흡광도 감소를 보였다 ISO 10993, part 5에 따라 구리는 "강한 독성"을 보이는 반면 티타늄과 스테인레스스틸 선재는 "무독성". 그리고 전기도금 선재는 "중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.

치과보철용 자석재료의 전기화학적 안정성 개선효과 (IMPROVEMENT EFFECTS OF ELECTROCHEMICAL STABILITY OF MAGNETIC MATERIALS FOR PROSTHETIC DENTISTRY)

  • 곽종하;오상호;최한철;정재헌
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.628-641
    • /
    • 2006
  • Statement of problem: Dental magnetic materials have been applied to removable prosthetic appliances, maxillofacial prostheses, obturator and dental implant but they still have some problems such as low corrosion resistance in oral environments. Purpose: To increase the corrosion resistance of dental magnetic materials, surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels. Materials and methods : Surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels, and then three kinds of electrochemical corrosion test were performed in 0.9% NaCl solution; potentiodynamic, potentiostatic, and electrochemical impedance test. From this study, corrosion behavior, amount of elements released, mean average surface roughness values, the changing of retention force, and magnetic force values were measured comparing with control group of non-coated magnetic materials. Results: The values of surface roughness of TiN coated Sm-Co and TiN coated Nd-Fe-B based magnetic materials were lower than those of non coated Sm-Co and Nd-Fe-B alloy. From results of potentiodynamic test, the passive current density of TiN coated Sm-Co alloy were smaller than those of TiN coated Nd-Fe-B alloy and non coated alloys in 0.9% NaCl solution. From results of potentiostatic and electrochemical impedance test, the surface stability of the TiN coated Sm-Co alloy was more drastically increased than that of the TiN coated Nd-Fe-B alloy and non-coated alloy. The retention and magnetic force after and before corrosion test did not change in the case of TiN coated magnetic alloy sealed with stainless steel. Conclusion: It is considered that the corrosion problem and improvement for surface stability of dental magnetic materials could be solved by ion plating with TiN on the surface of dental magnetic materials and by sealing with stainless steels.

ENEPIG 표면처리에서의 Sn-Ag-Cu 솔더조인트 신뢰성: 1. 무전해 Ni-P도금의 두께와 표면거칠기의 영향 (Reliability of Sn-Ag-Cu Solder Joint on ENEPIG Surface Finish: 1. Effects of thickness and roughness of electroless Ni-P deposit)

  • 허석환;이지혜;함석진
    • 마이크로전자및패키징학회지
    • /
    • 제21권3호
    • /
    • pp.43-50
    • /
    • 2014
  • 전자 제품의 경박 단소화 및 고집적화가 이루어 지면서 실리콘 집과 인쇄회로기판의 인터커넥션의 고신뢰도가 요구되고 있다. 본 연구는 Sn-4.0wt%Ag-0.5wt%Cu (SAC405) 솔더와 다양한 무전해 Ni-P 도금 두께에서의 high speed shear 에너지 및 파괴 모드를 연구하였다. 파괴 모드 분석을 위하여 집속이온빔(FIB) 분석이 이용되었다. 질산 기상 처리하지 않은 $1{\mu}m$ Ni-P 시편에서 낮은 shear 에너지가 나왔으며, 이는 솔더레지스트 선단에서 파단의 원인을 제공하는 것이 확인되었다. 질산 기상 처리한 시편에서 무전해 Ni-P 도금 두께가 커질수록 취성 파괴 모드는 감소한다. 또 Ni-P 도금 두께와 표면 거칠기(Ra)는 반비례 관계를 가진다. 이는 Ni-P 도금의 표면 거칠기를 낮추면 SAC405 솔더 조인트의 신뢰도를 향상시킨다는 사실을 나타낸다.

Ti-Al-Si-N 코팅막의 마모거동에 미치는 Si 함량의 영향 (The Effect of Si Content on the Tribological Behaviors of Ti-Al-Si-N Coating Layers)

  • 진형호;김정욱;김광호;윤석영
    • 한국세라믹학회지
    • /
    • 제42권2호
    • /
    • pp.88-93
    • /
    • 2005
  • 아크 이온 플레이팅과 스퍼터로 구성된 하이브리드 시스템을 이용하여 다성분계 Ti-Al-Si-N 코팅막을 WC-Co 기판에 증착하였다. 증착시 Si 함량을 변화시켜 코팅막의 마모특성에 Si 함량이 미치는 영향에 대하여 조사하였다. 마모 특성을 관찰하기 위하여 Ti-Al-Si-N 코팅막이 증착된 WC-Co 원판에 3N의 하중, 0.1 m/s의 속도로 볼 온 디스크(ball-on-disk) 형태의 마모시험기를 이용하여 건식 마모 실험을 하였다. 상대재로는 스틸볼과 지르코니아볼을 사용하였다. 상대재가 스틸볼의 경우 Ti-Al-Si-N 코팅막의 마찰계수가 Ti-Al-N 코팅막의 마찰계수보다 낮게 나타났다 이는 Si가 첨가되어 마모시 상대재와 코팅막 사이에 자기윤활효과(self-lubricant effect)에 의한 것으로 여겨진다. 코팅막과 스틸볼 사이에 응착 마모 거동을 보였으며, Si의 함량이 증가함에 따라 마찰계수는 감소하였다. 한편, 상대재가 지르코니아 볼의 경우 코팅막과 지르코니아 볼 사이에서 연삭마모 거동이 더 지배적이었고, Si 함량이 증가할수록 마찰계수는 증가하였다.

타이타늄 합금에 다양한 두께로 코팅된 TiN 피막의 기계적 성질 (MECHANICAL PROPERTIES OF TIN COATED FILM WITH VARIOUS COATING THICKNESS ON TITANIUM ALLOY)

  • 이재윤;오동준;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.675-686
    • /
    • 2007
  • Statement of problem: Titanium nitride(TiN) coatings are the most general and popular coating method and used to improve the properties of metallic surface for industrial purposes. When TiN coating applied to the abutment screw, frictional resistance would be reduced, as a results, the greater preload and prevention of the screw loosening could be expected. Purpose: The purpose of this study was to investigate mechanical properties of TiN coated film of various coating thickness on the titanium alloy surface and to evaluate proper coating thickness. Material and method: 95 Titanium alloy (Ti-6Al-4V) discs of 15 mm in diameter and 3 mm in thickness were prepared for TiN coating and divided into 7 groups in this study. Acceding to coating deposition time (CDT) with TiN by using Arc ion plating, were divided into 7 groups : Group A (CDT 30min), Group B (CDT 60min), Group C (CDT 90min), Group D (CDT 120min), Group E (CDT 150min), Group F(CDT 180min) and Group G (no CDT) as a control group. TiN coating surface was observed with Atomic Force Microscope(AFM), field emission scanning electron microscopy(FE-SEM) and examined with scratch tester, wear tester. Result: 1. Coating thickness fir each coated group was increased in proportion to coating deposition time. 2. Surface of all coated groups except Group A was homogeneous and smooth. However, surface of none coated Group G had scratch. 3. Adhesion strength for each coated group was increased in proportion to coating deposition time. 4. Wear resistance for each coated group was increased in proportion to coating deposition time. 5. Surface roughness in Group A, B, C was increased in proportion to coating deposition time. But, surface roughness in Group D, E, F was showed decreased tendency in proportion to coating deposition time. Conclusion: According to coating deposition time, mechanical properties of TiN coated film were changed. It was considered that 120 minutes coating deposition time ($1.32{\mu}m$ in coating thickness) is necessary.

박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구 (A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS)

  • 김형우;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

인쇄공정으로 제조된 저항형 습도센서의 감습특성에 대한 전극패턴의 영향 연구 (The Effect of Electrode Pattern on the Humidity-sensing Properties of the Resistive Humidity Sensor Based on All-printing Process)

  • 안희용;공명선
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.169-176
    • /
    • 2012
  • 저항형 습도센서의 개발을 위하여 스크린 인쇄방법으로 glass epoxy(GE) 기재 위에 핑거의 수와 그 사이의 간격이 다른 여러 가지 바이트형의 금 전극을 제조하였다. 전극의 기본적인 구조는 핑거 수가 3, 4 및 5를 가지며 간격은 각각 310과 460 ${\mu}m$이다. 전극은 처음에 은 나노 페이스트로 전극 패턴을 인쇄하고 연속적으로 Cu, Ni 및 Au를 무전해 도금을 진행하여 제조하였다. 감습성 고분자 전해질은 [2-(methacryloyloxy)ethyl] dimethyl benzyl ammonium chloride(MDBAC)과 methyl methacrylate(MMA)의 공중합체를 사용하였으며 스크린 인쇄 방법으로 Au 전극/GE 기재 위에 인쇄하였다. 이렇게 제조된 습도 센서의 20-95%RH 영역의 상대습도 대 로그 임피던스 그래프에서 좋은 직선성을 보여주었으며 히스테리시스는 1.5%RH 이하 및 75초의 응답 및 회복 속도를 보여주었다. 전극의 구조는 고분자 저항형 습도센서의 감습특성에 큰 영향을 미치며 전해질 고분자와 전극 사이의 활성화 에너지, 온도의존성, 감도, 직선성 및 히스테리시스와 같은 감습특성 등의 차이를 비교하였고 특히 이온의 이동에 관여하는 활성화 에너지 및 온도 의존성에 큰 영향을 미쳤다.