• 제목/요약/키워드: ion-chromatography

검색결과 1,273건 처리시간 0.028초

광화학적으로 제조된 Superoxide Radical을 이용한 Superoxide Dismutase를 생산하는 해양미생물의 탐색 및 효소정제 (Screening and Purification of Superoxide Dismutase Producing Marine Bacterium Using Photochemically Generated Superoxide Ion)

  • 조기웅
    • 미생물학회지
    • /
    • 제38권2호
    • /
    • pp.81-85
    • /
    • 2002
  • 해양세균으로부터 superoxide dismutase를 생산하는 균주를 광화학적 superoxide ion 형성 및 nitrite정량방법으로 검색하여 고활성 균주 B-446을 확보하고 본 균주로부터 35-75% ammonium sulfate precipitation, DEAE-Sephadex A-25 ion exchange chromatography, Sephadex C-200 gel filtration chromatography, High-Q anion exchange chromatography그리고 HPLC-GPC를 이용하여 수율 6%, 정제도 32.3 배의 정제된 SOD를 얻었으며 정제 과정중 효소활성 분석에 본 광화학적 superoxide ion생성 방법으로 사용하였다.

Ion Chromatography에 의한 음료수중 음이온 함량에 관한 연구 (Measurement of an Ion Concentration in Drinking Water by lon Chromatography)

  • 김형석
    • 환경위생공학
    • /
    • 제4권1호
    • /
    • pp.7-15
    • /
    • 1989
  • According to the increase of population and development of industrialization air and water pollution problems are still keeping going to great nuisance to human activities. Specially man should drink 2l clean water to maintain our health every day, but we afraid of drink the city tap water because of the contaminants like heavy metals, bacteria trihalomethane, etc. In the analysis of the anions in potable water, we usually adapt the Standard methods for the Examination of Water and Wastewater. But this method is tedious and time consuming, so the Ion Chromatography method is now used in research of water quality. Author worked with Ion Chromatography in measuring the anions in drinking water by attaching conductivity dector to normal High Performance Liquid Chromatograph. Low-capacity ion-exchange coulmn and dilute eluents, 0.00M phthalic aic was used in this study. The concentration of chloride ion was 1.55 ppm$\~$3 8.81ppm, nitrate ion was 5.45 ppm$\~$18.27ppm, and sulfate ion was 19.64 ppm$\~$28.86 ppm. The phosphate ion was detected only in Apt. tap water as 167.99 ppm whose amount was supposed to be used as a water pipe cleaner.

  • PDF

젤 여과, 이온 크로마토그래피와 HPLC에 의한 효모 엑기스내의 비타민의 분석연구 (Characterization of Vitamins in Yeast Extract using Gel Filtration, Ion Exchange Chromatography and HPLC)

  • 최인호;홍억기;강환구;김인호
    • KSBB Journal
    • /
    • 제15권1호
    • /
    • pp.76-79
    • /
    • 2000
  • Complex, ill-defined mixtures of natural origin are often used as nutrients in the production of biological products through microbial fermentation. Product yields are affected by variation in these natural products. Yeast extract is a typical example of these natural products. Since it is a mixture of amino acids, peptides and nucleic acids, its composition is not well characterized. In this study, we investigated the properties of thiamine hydrochloride, riboflavin and pyridoxine hydrochlride in yeast extract by using a gel filtration chromatography, ion exchange chromatography and high performance liquid chromatography. Yeast extract solution was fractionated by gel filtration chromatography and ion exchange chromatography, and then, each fraction was analyzed by using a high performance liquid chromatography.

  • PDF

단백질의 치환 크로마토그래피

  • 윤태호;김인호
    • 한국미생물생명공학회소식지:생물산업
    • /
    • 제13권2호
    • /
    • pp.13-17
    • /
    • 2000
  • 새로운 분리공정으로써 크로마토그래피를 이용하고자 하는 노력들이 활발하게 진행되어지고 있는 가운데, 기존의 전통적인 크로마토그래피를 더욱 발전시킨 시도들이 행하여지고 있다. 여기에 부합하여 약 20여년 전부터 연구되기 시작한 Displacement ion-exchange chromatography는 현재 활발한 연구가 진행되어지고 있으며, 전형적인 preparative chromatography에 비해 많은 장점을 가지고 있다. Displcement ionexchange chromatography는 displacer를 사용하여, 고농도의 원료 물질을 효율적으로 단시간내에 처리할 수 있는 공정으로 기존의 preparative chromatography의 문제점이었던 꼬리끌기 현상과 희시현상을 대폭 감소시킬 수 있게 되었다. 따라서, displacement ion-exchange chromatography 공정에서의 가장 큰 과제인 비선형 등온선 영역에서의 거동과 분리공정 조작선의 결정 및 고성능의 displacer에 대한 연구가 요구되어지고 있으며, 본 총론에서는 이온교환 크로마토그래피 공정에서 displacement ion exchange chromatography를 이용한 단백질의 분리에 대하여 고찰하고자 한다.

  • PDF

착유기 세척제가 유두컵 라이너 재질에 미치는 화학적 영향 (Chemical effect of the detergents used for cleaning a milking machine on the teatcup liner materials)

  • 이정치
    • 한국동물위생학회지
    • /
    • 제36권4호
    • /
    • pp.273-281
    • /
    • 2013
  • This study investigated the effects of the alkaline detergent and acid rinse used for cleaning milking machines on the eight commercially available teatcup liner materials. The sample liners prepared for use in the clean-in-place process were analyzed by ultraviolet spectrophotometer, ion chromatography and liquid chromatography. Among the eight liner materials, the ultraviolet spectra of 3 sample liners were shown to have a similar peak shape after cleaning, but the ultraviolet spectra peak shape of 5 sample liners was noticeably changed. No products were detected by ion chromatography in any of the liner materials used in this study. When the liner materials were only treated with alkaline detergent, some additional peaks were observed using liquid chromatography which indicate the creation of molecular substance and elution from liner materials, however, these peaks disappeared when the liner materials were cleaned with the acid rinse. Therefore, we propose that an acid rinse should be applied, after cleaning the milking machine with the alkaline detergent.

Isolation and Purification of Polysaccharide from Fruiting body and Culture Broth of Agaricus blazei Murill

  • Youm, Yong-Soo;Hong, Eock-Kee
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.343-347
    • /
    • 2005
  • The polysaccharides were extracted from fruiting body, mycelia, and cell-free broth of Agaricus blazei Murill. The crude polysaccharides were obtained by the ethanol addtion. They were further purified using ion-exchange chromatography and gel chromatography. Ion-exchange chromatography using DEAE-cellulose column separated neutral and acidic polysaccharides. Neutral polysaccharides were then purified with gel filtration chromatography. For single peak obtained from gel filtration chromatography was molecular weight was measured with Sepharose CL-6B. The same procedure with acidic polysaccharides were performed to get the purified polysaccharides.

  • PDF

이온 크로마토그래피용 모세관 컬럼의 개발 (Development of Capillary Columns for Ion Chromatography)

  • 김호현;표동진
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.521-527
    • /
    • 1999
  • 본 연구에서는 적은 양의 시료를 분석할 수 있는 이온 크로마토그래피용 모세관 컬럼을 개발하였다. 내경이 작은 모세관 컬럼을 사용하는 경우 이동상의 유속은 보통 $5{\sim}15{\mu}L/min$ 정도 되고 컬럼의 길이는 50~150 mm 정도이다. 컬럼은 RSL-300 fused silica 모세관(내경 : 0.53 mm, 외경 : 0.67 mm)과 AG14 column resin(support : polystyrene-divinylbenzene, functional group : aulkyl quatemary ammonium)을 이용하여 만들었다. 또한 이런 모세관 컬럼에 맞는 새로운 전도도 셀과 억제컬럼도 함께 개발하여 사용하였다. 이 모세관 컬럼을 이용하여 실제 음이온들(fluoride, nitrite, nitrate, chlorate)을 분석한 결과 재현성 있고 좋은 크로마토그램을 얻었다.

  • PDF

$\beta$-아밀라아제의 정제에 관한 연구 (Purification of Soybean $\beta$-Amylase)

  • 안용근
    • 한국식품영양학회지
    • /
    • 제7권1호
    • /
    • pp.23-28
    • /
    • 1994
  • Soybean $\beta$-amylase was purified by DEAE-cellulose ion exchange chromatography, Sephadex G-100 gel chromatography, CM Sephadex C-50 ion exchange chromatography and CM Sephadex C-50 ion exchange rechromatography The purified enzyme showed 1, 020 unit/mg of specific activity. The purified enzyme was identified as homogenious by disc PAGE and analysis of reaction product.

  • PDF

Suppressed 이온 크로마토그래피에서 과량의 양이온이 낮은 농도의 음이온 분석에 미치는 영향 (The Effect of High Concentration Cation Matrix on the Analysis of the Low Anion Concentration in Suppressed Ion Chromatography)

  • 강미정;이석근
    • 분석과학
    • /
    • 제11권6호
    • /
    • pp.495-498
    • /
    • 1998
  • The effect of high concentration ion matrix on the analysis of low anion concentration in the suppressed ion chromatography was studied. The anions studied were $Br^-$, $NO_3{^-}$, $HPO_4^{2-}$, $SO_4^{2-}$, and $C_2O_4^{2-}$ in the presence of excess NaCl and $CaCl_2$. In this study we suggested that the erroneous results in the suppressed ion chromatographic determination of small concentration of anions were not caused by the interaction of large amount of cation in the suppressor, but by the interaction of cation with concerned anion in the original solution. The error in the analysis of such anion can not be eliminated just by dilution. Therefore, we suggested that standard addition method might be adequate for analyses of those samples.

  • PDF