Sensitivity of Lavender to Proton, Electron, and Gamma Radiation

  • Chen, Wensheng;Li, Hui;Shi, Lei;Bai, Hong Tong
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.122-133
    • /
    • 2016
  • While ion beams are widely used in plant breeding, little is known about the sensitivity of Lavandula angustifolia (lavender) to ionizing radiation. To compare the biological effects of different types of ionizing radiation on the germination and survival rates of lavender, we exposed lavender seeds to gamma rays, 3 MeV electron beams, and 1.89 MeV proton ion beams. We observed that the seed germination rate decreased with increasing dosages of all three types of ionizing radiation. The malformation rate of lavender seedlings exposed to electron beams and gamma rays increased with increasing radiation dosage. By contrast, the effect of the accelerated proton beams on the malformation rate was negatively correlated with the dosage used. The survival rate of lavender seedlings exposed to the three types of ionizing radiation decreased in a dose-dependent manner. In addition, the survival rate of seedlings irradiated with proton and electron beams decreased more slowly than did that of seedlings irradiated with gamma rays. The half-lethal dose of gamma rays, electron beams, and proton beams was determined to be 48.1 Gy, 134.3 Gy, and 277.8 Gy, respectively, and the most suitable proton-ion energy for lavender seeds in terms of penetration depth was determined to be 5 MeV. These findings provide valuable information for the breeding of lavender by radiation mutation.

The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line (초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발)

  • Ju, Mun-No;Yang, Kwang-Ho;Lee, Dong-Il;Shin, Koo-Yong;Lim, Jae-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

Fabrication and polysilicon Resistors Compensated with Boron and Phosphorous Ion-Implantation (Boron과 Phosphorous 이온주입에 의한 다결정 실리콘 저항의 제조)

  • 김지범;최민성
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.813-817
    • /
    • 1987
  • High value sheet resistance (Rs' 1K-33K\ulcorner/) polysilicon resistors were fabricated using double ion implantation with boron as the major dopant and phosphorus compensation. It is observed that Rs sensitivity to the net doping concentration is decreased by one order of magnitude compared to the conventional (boron implanted)polysilicon resistors. The temperature co-efficient of resistance (TCR) measured between 25\ulcorner and 125\ulcorner shows equivalent values to those of non-compensated resistors for the same Rs. A qualitative electrical conductiion mechanism for compensated polysilicon resistor is proposed, based on the existing grain boundary charge trapping theory.

  • PDF

Relative Hydrophobicity of Triphenylmethane Dyes as Revealed by Interaction with Tetraarylborate Anions

  • Lee, Beom-Gyu;Yoon, Kil-Joong;Kim, Jin-Doo;Kim, Kang-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.4
    • /
    • pp.357-359
    • /
    • 1989
  • The ion aggregates formed between cationic triphenylmethane dyes and tetraphenylborate(TPB) or tetrakis(4-fluorophenyl) borate (TFB) anions have been investigated spectroscopically. The photometric sensitivities of the dyes are found to be increasing in the order pararosaniline < malachite green < methyl violet 2B < crystal violet < ethyl violet. Cetyltrimethylammonium bromide(CTAB) and Triton X-100(TX-100) destroy the ion aggregates. By comparing the concentration of surfactant beyond which dye-borate mixed solutions behave identically with the dye blank, the order of hydrophobicity appears to be parallel with that of photometric sensitivity.

Ca2+-regulated ion channels

  • Cox, Daniel H.
    • BMB Reports
    • /
    • v.44 no.10
    • /
    • pp.635-646
    • /
    • 2011
  • Due to its high external and low internal concentration the $Ca^{2+}$ ion is used ubiquitously as an intracellular signaling molecule, and a great many $Ca^{2+}$-sensing proteins have evolved to receive and propagate $Ca^{2+}$ signals. Among them are ion channel proteins, whose $Ca^{2+}$ sensitivity allows internal $Ca^{2+}$ to influence the electrical activity of cell membranes and to feedback-inhibit further $Ca^{2+}$ entry into the cytoplasm. In this review I will describe what is understood about the $Ca^{2+}$ sensing mechanisms of the three best studied classes of $Ca^{2+}$-sensitive ion channels: Large-conductance $Ca^{2+}$-activated $K^+$ channels, small-conductance $Ca^{2+}$-activated $K^+$ channels, and voltage-gated $Ca^{2+}$ channels. Great strides in mechanistic understanding have be made for each of these channel types in just the past few years.

Isolation of Cadmium Ion-resistant Bacteria and Resitance to Various Heavy Metals (카드봄 내성균의 분리와 각종 중금속에 대한 저항성의 연구)

  • Yeeh, Yeehn;Lee, Jong-Kun
    • Korean Journal of Microbiology
    • /
    • v.17 no.2
    • /
    • pp.49-57
    • /
    • 1979
  • Cadimium ion-resistant microorganism was isolated from the sludge of wastewater. The physiological, morphological and other cultural data showed that this strain belonged to Citrobacter freudii. A clearcut distinction of growth among nutrient broth, typtic soy broth and synthetic medium was demonstrated. The resistant cells showed only slight mutagenic action. During the growth of bacterial population in resting state, the organisms reduced the initial level of resistance to cadmium ions when they were not kept in contact with cadmium ions in bacteral multiplication. And cadmium ion-resistant and cadmium ion-sensitive strain were found to show equal, lower or higher sensitivity to other heave metals.

  • PDF

Fast Protein Staining in Sodium Dodecyl Sulfate Polyacrylamide Gel using Counter ion-Dyes, Coomassie Brilliant Blue R-250 and Neutral Red

  • Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.704-708
    • /
    • 2002
  • A fast and sensitive protein staining method in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) using both an acidic dye, Coomassie Brilliant Blue R-250 (CBBR) and a basic dye, Neutral Red (NR) is described. It is based on a counter ion-dye staining technique that employs oppositely charged two dyes to form an ion-pair complex. The selective binding of the free dye molecules to proteins in an acidic solution enhances the staining effect of CBBR on protein bands, and also reduces gel background. It is a rapid staining procedure, involving fixing and staining steps with short destaining that are completed in about 1 h. As the result, it showed two to fourfold increase in sensitivity comparing with CBBR staining. The stained protein bands can be visualized at the same time of staining.

Alizarin Red S modified electrochemical sensors for the detection of aluminum ion

  • Chang, Seung-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.421-427
    • /
    • 2010
  • Alizarin Red S modified screen printed carbon electrodes were developed for the electrochemical detection of aluminum ion. The electrodes developed use screen-printed carbon electrodes(SPCEs) coupled with chemical modification with an organic chelator, Alizarin Red S(ARS), for aluminum ion detection in aqueous solution. For sensor fabrication ARS was directly immobilized on the surface of SPCEs using PVA-SbQ(The poly(vinyl alcohol) bearing stryrylpyridinium groups). Aluminum concentrations were indirectly estimated by amperometric determination of the non-complexed ARS immobilized on the electrodes, after its complexation with aluminum. The sensitivity of the sensor developed was $3.8\;nA{\mu}M^{-1}cm^{-2}$ and the detection limit for aluminum was $25\;{\mu}M$.

Green flow injection spectrophotometric system for lead ion (II) evaluation in vegetables samples using new azo reagent

  • Fatimah Lateef Al-Zubaidi;Khdeeja Jabbar Ali
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • A new, sensitive, and reliable flow injection methodology was investigated for the determination of lead ion (II) in vegetables' samples using a laboratory-prepared reagent 2-[(6-methoxy-2-benzothiazoly)azo]-4-methoxy phenol (6-MBTAMP). Infrared spectroscopy, UV-visible spectrophotometry, Energy dispersive X-ray spectroscopy (EDX), Elemental Analysis (CHN), nuclear magnetic resonance spectroscopy 1HNMR, and 13CNMR techniques were used to characterize the reagent and lead (II) complex. The method is based on lead ion (II) reacting with the reagent (6-MBTAMP) in a neutral solution to produce a green-red complex with a maximum absorbance at 670 nm. The optimum conditions, such as flow rate, lead ion (II) volume, reagent volume, medium pH, reagent concentration, and reaction coil length were thoroughly examined. The limits of detection (LOD) and quantification (LOQ) were determined to be 0.621 mg·L-1 and 2.069 mg·L-1 , respectively, while Sandell's sensitivity was determined to be 0.345 ㎍·cm-2.

Turn-On Type Fluorogenic and Chromogenic Probe for the Detection of Trace Amount of Nitrite Ion in Water

  • Saleem, Muhammad;Abdullah, Razack;Hong, In Seok;Lee, Ki-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.389-393
    • /
    • 2013
  • A rhodamine B-based fluorescent probe for nitrite ion ($NO{_2}^-$) has been designed, synthesized, characterized and its properties for recognition of $NO{_2}^-$ were studied. Nearly non fluorescent probe upon reaction with nitrite ion significantly triggered the fluorescence. Fluorescence response is based on ring opening of the spirolactam of rhodamine B phenyl hydrazide showing maximum absorbance at 552 nm and maximum emission at 584 nm. Probe 3 exhibited high sensitivity and extreme selectivity for nitrite ion over other common ions and oxidants ($Cl^-$, $ClO^-$, $ClO{_2}^-$, $ClO{_3}^-$, $ClO{_4}^-$, $SO{_4}^{2-}$, $SiO{_3}^{2-}$, $NO{_3}^{2-}$, $CO{_3}^{2-}$) examined in methanol water (1:1, v/v) at pH 7.0. The probe might be a new efficient tool for detection of nitrite ion in natural water and biological system.