• Title/Summary/Keyword: ion leakage

Search Result 174, Processing Time 0.031 seconds

The Electrical properties of Al/TiN/Ti Contact at Submicron contact(2) (Al/TiN/Ti 전극의 Submicron contact에서의 전기적특성(2))

  • Lee, C.J.;Eum, M.J.;Ra, Y.C.;Kim, S.J.;Sung, M.Y.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1069-1071
    • /
    • 1995
  • The electrical properties of Al/TiN/Ti contact are investigated at submicron contacts. The contact resistance and contact leakage current are dependent on metallization, surface dopant concentration, semiconductor surface treatment and contact plug ion implantation. In this paper, the contact resistance and contact leakage current are studied according to surface dopant concentration, semiconductor surface treatment and contact plug ion implantation at 0.8 micron contact. The contact resistance and contact leakage current increases with increasing substrate ion concentration. HF cleaning represents high contact resistance but low contact leakage current while CDE cleaning represents low contact resistance but high contact leakage current. Contact plug ion implantation decreases contact resistance but increases contact leakage current. Specially, RTA represents good electrical properties.

  • PDF

Development of Column ion Exchange Modeling with Successive Ion Exchange Equilibrium (연속이온교환평형 칼럼 모델 개발)

  • 이인형
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.141-145
    • /
    • 2002
  • Successive ion Exchange Column model was developed with the combination of mass action law and mole balance equation. consuming that ions entering the ion exchange bed pass the resin layer via consecutive ion exchange equilibrium. The application of the model to condensate polishing demineralizer in nuclear power plants indicates that the leakage of $Na^+$ and $Cl^-$ depends upon the degree of resin regeneration and that the ratio of specific ion concentration in Influent to in effluent is subject to the characteristics of resin and solution. The model can account for the local in-equilibrium with the correction of resin concentration and also can be applicable to a competitive ion exchange.

  • PDF

Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion (전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구)

  • Choi, Chung-Seog;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

Dependence of Na+ leakage on intrinsic properties of cation exchange resin in simulated secondary environment for nuclear power plants

  • Hyun Kyoung Ahn;Chi Hyun An;Byung Gi Park;In Hyoung Rhee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.640-647
    • /
    • 2023
  • Material corrosion in nuclear power plant (NPP) is not controlled only by amine injection but also by ion exchange (IX) which is the best option to remove trace Na+. This study was conducted to understand the Na+ leakage characteristics of IX beds packed with ethanolamine-form (ETAH-form) and hydrogen-form (H-form) resins in the simulated water-steam cycle in terms of intrinsic behaviors of four kinds of cation-exchange resins through ASTM test and Vanselow mass action modeling. Na+ was inappreciably escaped throughout the channel created in resin layer. Na+ leakage from IX bed was non-linearly raised because of its decreasing selectivity with increasing Na+ capture and with increasing the fraction of ETAH-form resin. Na+ did not reach the breakthrough earlier than ETAH+ and NH4+ due to the increased selectivity of Na+ to the cation-exchange resin (H+ < ETAH+ < NH4+ ≪ Na+) at the feed composition. Na+ leakage from the resin bed filled with small particles was decreased due to the enhanced dynamic IX processes, regardless of its low selectivity. Thus, the particle size is a predominant factor among intrinsic properties of IX resin to reduce Na+ leakage from the condensate polishing plant (CPP) in NPPs.

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Characterizations of Commercial Bipolar Membranes for Efficient Electrochemical LiOH Production (효율적인 전기화학적 LiOH 생산을 위한 상용 바이폴라막 특성 분석)

  • Song, Hyeon-Bee;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.32 no.5
    • /
    • pp.357-365
    • /
    • 2022
  • Recently, as the demand for secondary batteries for electric vehicles has rapidly increased, the efficient production of lithium compounds is attracting great attention. Bipolar membrane electrodialysis (BPED) is known as an eco-friendly, economical, and efficient electrochemical lithium compound production process. Since the efficiency of the BPED depends on the performance of the bipolar membrane (BPM), the selection of the BPM is very important. In this study, the characteristics of BPMs suitable for the BPED for electrochemical LiOH production were derived by comparative analyses of BP-1E (Astom) and FBM (Fumatech), which are the most widely used commercial BPMs in the world. Through systematical evaluation, it was confirmed that reducing membrane ion transfer resistance and co-ion leakage among the characteristics of BPM is the most important, and BP-1E has better performance than FBM in this respect.

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결합제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\sub$p/ (projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결함제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. Triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\_$p/ (Projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

ON THE INTERFACE BETWEEN TITANIUM METAL AND BONE TISSUE -Ti-ion leakage from bone and implant interface(1)- (티타늄금속과 골조직의 계면에 관한 연구 -골과 임플란트 계면에서의 Ti-ion의 거동에 대하여(1)-)

  • Cho, Sung-Am;Jo, Kyung-Hun;Sur, Jo-Ryung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.354-357
    • /
    • 1995
  • The secondary ion of titanium from commercially pur titanium implant which installed at Rabbit tibia. Was analyzed by Secondary lon Mass Spectroscopy. And we detected about 3476 ppm ion from $10-50{\mu}m$ distance from interface.

  • PDF

Oxidative Stress and Antioxidant Responses in Poplar Clones Irrigated with Livestock Waste Leachate (양돈폐수 처리에 의한 포플러클론의 산화스트레스와 항산화반응)

  • Je, Sun-Mi;Yeo, Jin-Gi;Woo, Su-Young
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • We studied the influence of livestock waste leachate on oxidative damage and antioxidative responses in poplar clones in August which increase the demand of antioxidants because of high temperature and high light during this period. We measured ion leakage, antioxidant enzyme activities (APX, GR), and carotenoid contents. Oxidative damage and antioxidative responses by treated livestock waste leachate in poplar clones showed various results. We divided poplar clones into three groups using the criteria based on ion leakage which represent cell damage induced oxidative stress. Eco 28, 62-10, Bonghwa1 and Dorskamp belonged to the first group in which the cell damaged level was lower than that of the control. The results suggest that this group augmented for demand of antioxidative in summer because high concentration of nitrogen induced by treatment of live stock wastes acted as environmental stress. Consequently, they failed to keep up the homeostasis of reactive oxygen species. The second group in which the cell damaged level was similar to that of the control was Suwon, 72-30 and 72-31 clones. Finally, 97-18 clone belonged to the third group in which the cell damaged level was lower than that of the control group. In this case, nitrogen treated by livestock waste leakage decreased oxidative stress. 97-18 clone was the clones with the least damage in summer oxidative stresses treated by livestock waste leakage. These results suggest that the high concentration nitrogen due to the livestock waste leakage can act differently upon the clones. We speculate that the added oxidation damage in the summer (growing season) may have an effect on the total fresh weight and also influence the purification ability for livestock waste leakage. However, further studies are needed for the confirmation.