• 제목/요약/키워드: ion detector

검색결과 187건 처리시간 0.027초

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

Analysis of Wide-gap Semiconductors with Superconducting XAFS Apparatus

  • Shiki, S.;Zen, N.;Matsubayashi, N.;Koike, M.;Ukibe, M.;Kitajima, Y.;Nagamachi, S.;Ohkubo, M.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.99-101
    • /
    • 2012
  • Fluorescent yield X-ray absorption fine structure (XAFS) spectroscopy is useful for analyzing local structure of specific elements in matrices. We developed an XAFS apparatus with a 100-pixel superconducting tunnel junction (STJ) detector array with a high sensitivity and a high resolution for light-element dopants in wide-gap semiconductors. An STJ detector has a pixel size of $100{\mu}m$ square, and an asymmetric layer structure of Nb(300 nm)-Al(70 nm)/AlOx/Al(70 nm)-Nb(50 nm). The 100-pixel STJ array has an effective area of $1mm^2$. The XAFS apparatus with the STJ array detector was installed in BL-11A of High Energy Accelerator Research Organization, Photon Factory (KEK PF). Fluorescent X-ray spectrum for boron nitride showed that the average energy resolution of the 100-pixels is 12 eV in full width half maximum for the N-K line, and The C-K and N-K lines are separated without peak tail overlap. We analyzed the N dopant atoms implanted into 4H-SiC substrates at a dose of 300 ppm in a 200 nm-thick surface layer. From a comparison between measured X-ray Absorption Near Edge Structure (XANES) spectra and ab initio FEFF calculations, it has been revealed that the N atoms substitute for the C site of the SiC lattice.

스마트 홈에서 연소에 따른 화재감지기 원격 IoT 작동 시간에 관한 연구 (A Study on Remote IoT operating time for Fire Detector of Smart Home)

  • 고은영;홍성호;차재상
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.235-238
    • /
    • 2020
  • 스마트홈 시대에 화재안전은 인명 및 시설안전에 매우 중요한 사항이다. 화재로 인한 사상자 및 재산상 피해는 국가적으로 큰 손실일 것이다. 본 논문에서는 스마트홈에서 화재에 따라 화재감지기 작동시간을 판단하여 위험성을 예측할 수 있도록 제안하고자 한다. IoT 화재감지기인 열감지기와 연기감지기 중에서 화재에 따라 작동하는 시간의 차이로 인하여 위험성을 예측을 할 수 있다. 본 실험결과를 바탕으로 이온식 연기감지기가 매우 빠른 특성을 보여 추후 화재예방시설시에 본 결과물이 잘 활용되면 좋을 것이다.

용해기체 분석용 기체 감응막 이온선택성 전극 (제 1 보). 관형 PVC 막 pH 전극을 이용한 아질산이온의 연속·자동화 정량 (Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (I). Continuous-Automated Determination of Nitrite Ion Using Tubular PVC Membrane Type of pH Electrode)

  • 이흥락;윤종훈
    • 대한화학회지
    • /
    • 제33권4호
    • /
    • pp.388-398
    • /
    • 1989
  • 기체 감응막전극을 이용하여 수용액 중의 아질산이온을 연속${\cdot}$자동화법으로 정량하는 방법을 개발하였다. 이 방법에서 최종검출기로 쓴 이온선택성 전극은 관형 PVC막 pH 전극이었다. 장치계의 최적조건에서 구한 아질산이온 표준시료에 대한 전극의 감응기울기는 63.5mV/decade 이었으며, 직선감응 범위는 $2.5{\times}10^{-4}\; M{\sim}7.5 {\times} $10^{-2}$M 이었고, 검출한계는 $8.0{\times} 10^{-5}$M이었다. 이 방법은 다른 정량법보다 산성기체종의 방해를 적게 받을 뿐만 아니라 정량에 필요한 시간도 훨씬 단축할 수 있었다.

  • PDF

환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화 (Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples)

  • 김협;홍종기;김용화;김경례
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권1호
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

간접 분광 검출법에 의한 음이온의 분석(I) (Analysis of Anions by Indirect Photometric Detection (I))

  • 박만기;김박광;박정일;김경호;이미영;정재은
    • 약학회지
    • /
    • 제34권3호
    • /
    • pp.215-218
    • /
    • 1990
  • An ion chromatographic method based on indirect photometric detection of UV transparent anions was developed. Separation of anion was accomplished on strong anion exchange column (Waters SAX) using UV detector at 254 nm. Among examined UV-active additives (Dns-H, Dns-glu, Dnsser, Dns-val), Dns-glu showed the highest sensitivity. Studies on the effects of the pH and ionic strength of eluent revealed that the increase of pH and ionic strength of the eluent decreased capacity factor. The best eluent for the separation of acetate, fluoride, chloride, nitrate and bromide was $1\;{\times}\;10^{-4}M$ Dns-glu in 5 mM phosphate buffer (pH 6.30). The detection limit of chloride ion was 2.1 ng in this condition.

  • PDF

Calibration of TEPC for CubeSat Experiment to Measure Space Radiation

  • Nam, Uk-Won;Park, Won-Kee;Lee, Jaejin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Kim, Sunghwan;Jin, Ho;Lee, Seongwhan;Kim, Jungho;Kitamura, Hisashi;Uchihori, Yukio
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권2호
    • /
    • pp.145-149
    • /
    • 2015
  • A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.

Effect of a Series Connection of a Bi-Electrolyte Hydrogen Sensor in a Leak Detector

  • Han, Hyeuk Jin;Park, Chong Ook;Hong, Youngkyu;Kim, Jong Suk;Yang, Jeong Woo;Kim, Yoon Seo
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.6-9
    • /
    • 2015
  • Conventional leak detectors are widely based on helium gas sensors. However, the usage of hydrogen sensors in leak detectors has increased because of the high prices of helium leak detectors and the dearth in the supply of helium gas. In this study, a hydrogen leak detector was developed using solid-state hydrogen sensors. The hydrogen sensors are based on Park-Rapp probes with heterojunctions made by oxygen-ion conducting Yttria-stabilized zirconia and proton-conducting In-doped $CaZrO_3$. The hydrogen sensors were used for determining the potential difference between air and air balanced 5 ppm of $H_2$. Even though the Park-Rapp probe shows an excellent selectivity for hydrogen, the sensitivity of the sensor was low because of the low concentration of hydrogen, and the oxygen on the surface of the sensor. In order to increase the sensitivity of the sensor, the sensors were connected in series by Pt wires to increase the potential difference. The sensors were tested at temperatures ranging from $500-600^{\circ}C$.

Polychlorinated biphenyl 전처리한 횐쥐 간장의 S-9 분획에서 Stanozolol의 Hydroxylation 대사체의 생성 (In vitro Metabolism of Stanozolol to 3'-Hydroxystanozolol in the Liver S-9 Fraction of Polychlorinated Biphenyl-treated Rats)

  • 권오승;류재천
    • 약학회지
    • /
    • 제44권5호
    • /
    • pp.379-383
    • /
    • 2000
  • Stanozolol (STZ, 17$\alpha$-methyl-17$\beta$-hydroxy-5$\alpha$-androstano-(3,2-c) pyrazole), an anabolic steroid, is an abused drug by body-builders or atheletes, as well as medicine for treatment of aplastic anemia and vascular thrombosis. In human volunteers, the major urinary metabolite of STZ was reported to be 3'-hydroxystanozolol that was identified by gas chromatography-mass selective detector (GC/MSD). The objective of this experiment is to investigate the in vitro metabolism of STZ in liver S-9 faction of polychlorinated biphenyl-induced rats. Reaction mixture including STZ as substrate and the S-9 faction was extracted with diethyl ether and quantified by the selected ion monitoring mode of GC/MSD. The selected concentration of substrate STZ is 100 nmole and the selected time for incubation in the reaction mixture was determined to 60 min. The amount of 3'-hydroxystanozolol produced was increased by about 6-fold in the reaction medium including the liver S-9 fraction of polychlorinated biphenyl-induced rats, compared to that of untreated rats. Inhibitors of cytochrome P450, SKF-525A and 7,8-benzoflavone, decreased the production of 3'-hydroxystanozolol by about 89~100% and 65~75%, respectively; In conclusion, hydroxylation of STZ into 3'-hydroxystanozolol is confirmed by GC/MSD and is catalyzed by cytochrome P450.

  • PDF

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF