• 제목/요약/키워드: ion detector

검색결과 187건 처리시간 0.026초

원유중 Ivermectin 구충제의 잔류실태 조사 (Examination of ivermectin residues in raw milk after skin administration)

  • 박준조;육지혜;김휴경;박혜원;김인경;이우성
    • 한국동물위생학회지
    • /
    • 제30권3호
    • /
    • pp.421-428
    • /
    • 2007
  • This study was conducted two kinds of aims: 1) to modify the analytical methods (conditions) by high performance liquid chromatography - fluorescence detector for the detection of residual ivermectin in raw milk, 2) to provide basic information for the evaluation of standard of the residual ivermectin in raw milk. It could be considerable that negative ion spectra can be better method in the LC/MS analysis for the detection of residues, Characteristic daughter ions were observed in negative ion spectra, however, linear line was not formed in positive ion one. Three Holstein cows ($500{\pm}10kg$) were applied to commercial ointment of ivermectin just one time at the first day of test, and residues in raw milk were examined for 20day after administration. The limit of detection (LOD) was 0.65ng (n=5) by HPLC/FLD, and recovery rates were $87.85%{\sim}99.47%$. The peak was observed at the 4th day, and residues lasted to the end. Thus ivermectin was prohibited when lactating.

A study of detector size effect using Monte Carlo simulation

  • Park, Kwang-Yl;Yi, Byong-Yong;Vahc, Young W.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.36-38
    • /
    • 2004
  • The detector size effect due to the spatial response of defectors is one critical source of inaccuracy in clinical dosimetry and has been a subject of numerous studies. Conventionally, the detector response kernel contains all of the influence that the detector size has on the measured beam profile. Various analytic models for this kernel have been proposed and studied in theoretical and experimental works. Here, we use a method to determine detector response kernel simply by using Monte Carlo simulation and convolution theory. Based on this numerical method and DOSIMETER, an EGS4 Monte Carlo code, the detector response for a Farmer type ion chamber embedded in water phantom is obtained. There exists characteristic difference in the simulated chamber readings between one with carbon graphite wall and the other with Acrylic wail. Using the obtained response and the convolution theory, we are planning to derive the detector response kernel numerically and remove detector size effect from measurements for 6MV, 10${\times}$l0cm2 and 0.5${\times}$10 cm2 photon beam.

  • PDF

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

개체 독립형 건축물 침입감지기 개발 (Development of Individual Trespassing Detector for Building)

  • 김명호
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.400-403
    • /
    • 2008
  • In this work, an individual trespassing detector using a PIR sensor to detect infrared rays only between the range of $9.4{\sim}10.4{\mu}m$ radiated from the body is proposed. This detector using FIR sensor detects not insect or object but human body, It doesn't restrict the inhabitant's behavior because the filter of pm sensor is designed to have face angle and the detector only detects the window area. The existing wide angle filter, RIR sensor, detects $30^{\circ}$ angle while the face angle filter sensor on this paper detects $11^{\circ}$ angle with 3cm of face angle filter from 2m of detecting distance. In case of interruption of electric power, 250mAh of lithium-ion battery has worked for 10 hours consuming 22mA in normal state. Meanwhile, in case of interruption of electric power, 250mAh of battery has worked for 4 hours consuming 60mA in trespassing detecting state. Projector, receptor, controller and alarm are put on one PCB in order to make it convenient to install without any special installation skill.

Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam

  • Hirai, Masaaki;Kanai, Tatsuaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.231-232
    • /
    • 2002
  • We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm$^2$ and 2mm (depth).

  • PDF

Effect of Bile Salt on the Pharmacokinetics of Bretylium in the Rat (I) - Increased Lipophiiicity of Bretylium by Ion-Pair Complexation with Taurodeoxycholate -

  • Shim, Chang-Koo;Chung, Suk-Jae;Lee, Jeong-Uk;Lee, Min-Hwa;Kim, Shin-Keun
    • Archives of Pharmacal Research
    • /
    • 제9권2호
    • /
    • pp.111-114
    • /
    • 1986
  • Bretylium tosylate is a quaternary ammonium compound used for the treatment of ventricular fibrilation in humans. It is advantageous to other cationic compound in the study of biliary excretion in that negligible amount is bound to plasma protein and metabolite is not likely is to be formed. Some researchers reported that the formation of ion-pair complex caused to increase the lipothilicity of cationic compound. The partition of bretylium between water and organic phase was increased with the addition of sodium taurodeoxycholate. Also sensitive gas chromatographical assay procedure using flame ionization detector was studied. This procedure can detect as low as 0.1 mg/ml using 0.1 ml biological sample, but contamination by previous injection is the major problem of this method.

  • PDF

기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구 (Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권3호
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정 (LET Calibration of Fe 500 MeV/u Ions using SSNTD)

  • 김성환
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.41-45
    • /
    • 2016
  • In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ($\overline{y_D}$) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.

초소형 질량 분석기를 위한 이온 발생기의 열전자 방출 시험 (Hot Electron Emission Test of an Ion Source for a Micro Mass Spectrometer)

  • 운현중;김정훈;박태규;양상식;정광우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.419-422
    • /
    • 2001
  • This paper presents the principle and fabrication of a novel micro mass spectrometer and emission test of hot electron for ionization. A micro mass spectrometer consists of a micro ion source and a micro ion separator. The micro ion source consists of a hot filament and grid electrodes. Electrons emitted from a hot filament are to ionize some sample molecules. The ions are accelerated to an ion detector by an electric field. Mass can be analyzed by using the time of fight depending on the mass-to-charge ratio. The current of hot electron emission from the hot filament is measured for various input voltages.

  • PDF