• Title/Summary/Keyword: ion dependency

Search Result 48, Processing Time 0.021 seconds

Electrochemical Studies on the Lanthanides (란탄족 원소의 전기화학적 환원에 관한 연구 (제 1 보))

  • Park, Jong Min;Gang, Sam U;Do, Lee Mi;Han, Yang Su;Son, Byeong Chan
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.561-568
    • /
    • 1990
  • Voltammetric behavior of some light lanthanide ions (La$^{3+}$, Pr$^{3+}$, Nd$^{3+}$, Sm$^{3+}$, and Eu$^{3+}$) in various supporting electrolytes has been investigated by several electrochemical techniques. The peak potentials and the peak currents, their dependency on the concentration, temperature and pH effects, the reversibility of the electrode reactions are described. The reduction of La$^{3+}$, Pr$^{3+}$ and Nd$^{3+}$ in 0.1 M lithium chloride proceeds by a three-electron change directly to the metallic state (Ln$^{3+}$ + 3e- → Ln$^0$) and charge transfer is totally irreversible. However, the reduction of Sm$^{3+}$ in 0.1 M tetramethylammonium iodide and Eu$^{3+}$ in 0.1 M lithium chloride proceeds in two stages (Ln$^{3+}$ + e- → Ln$^{2+}$ and Ln$^{2+}$ + 2e- → Ln$^0$). At pH values lower than ca.4 the hydrated lanthanide species (Ln(OH)$^{2+}$) reduced before the lanthanide ions (Ln$^{3+}$) due to the catalytic effect of hydrogen ions, and peak current increase with in the order Eu$^{3+}$ < Sm$^{3+}$ < Nd$^{3+}$ < Pr$^{3+}$ < La$^{3+}$ in differential pulse polarography. Some representative plots of $i_{pc}V^{-1/2} (proportional to current function) vs. V show considerable influence of hydrogen ion/lanthanide ion concentration in cyclic voltammetry. It is shown that a reaction of lanthanide ions with proton and/or water and catalytic reaction is enhanced at lower pH and at decreased lanthanide ion concentration.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Effects of Calcium Ion Concentration on Starch Hydrolysis of Barley ${\alpha}$-Amylase Isozymes

  • Yuk, Jeong-Bin;Choi, Seung-Ho;Lee, Tae-Hee;Jang, Myoung-Uoon;Park, Jung-Mi;Yi, Ah-Rum;Svensson, Birte;Kim, Tae-Jip
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.730-734
    • /
    • 2008
  • Barley ${\alpha}$-amylase genes, amy1 and amy2, were separately cloned into the expression vector of $pPICZ{\alpha}A$ and recombinant Pichia strains were established by homologous recombination. Both AMYs from Pichia shared almost identical hydrolysis patterns on short maltooligosaccharides to result in glucose, maltose, or maltotriose. Against insoluble blue starch, AMY1 showed the highest activity at 0.1-5 mM calcium concentration, whereas 15-20 mM was optimal for AMY2. On the hydrolysis of soluble starch, unexpectedly, there was no significant difference between AMYs with increase of calcium. However, the relative activity on various starch substrates was significantly different between AMYs, which supports that the isozymes are clearly distinguished from each other on the basis of their unique preferences for substrates.

Floral Nectary-specific Gene NTR1 Encodes a Jasmonic Acid Carboxyl Methyltransferase

  • Seo, Hak Soo;Song, Jong Tae;Koo, Yeon Jong;Jung, Choonkyun;Yeu, Song Yion;Kim, Minkyun;Song, Sang Ik;Lee, Jong Seob;Hwang, Ingyu;Cheong, Jong-Joo;Choi, Yang Do
    • Journal of Applied Biological Chemistry
    • /
    • v.44 no.3
    • /
    • pp.119-124
    • /
    • 2001
  • NTR1 gene of Brassica campestris L. ssp. perkinensis encodes a floral nectary-specific methyltransferase. In this study, the NTR1 cDNA was expressed in E. coli to examine the enzymatic characteristics of the protein product. The GST-NTR1 fusion protein was purified to near homogeneity, showing that the size of NTR1 was 44 kDa. The protein reacted specifically with jasmonic acid (JA), consuming methyl group from S-adenosyl-L-methionine (SAM). GC-MS analysis revealed that the compound produced was authentic methyl jasmonate (MeJA), suggesting that NTR1 is an S-adenosyl-L-methionine: jasmonic acid carboxyl methyltransferase. Km values of NTR1 for JA and SAM were 38.0 and $6.4{\mu}M$, respectively. Optimal activity of the NTR1 was observed at $20^{\circ}C$, pH 7.5, in the presence of 100-150 mM KCl. Thus, kinetic properties, thermal characteristics, optimal pH, and ion-dependency of the NTR1 activity were almost identical to those of Arabidopsis JA methyltransferase JMT, indicating that these two proteins are orthologues of each other.

  • PDF

The Behavior of the Mobility Degradation in Pocket Implanted MOSFETS (Halo 구조의 MOSFET에서 이동도 감소 현상)

  • Lee Byung-Heon;Lee Kie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.4 s.334
    • /
    • pp.1-8
    • /
    • 2005
  • The increased effective impurity due to the pocket ion implantation is well blown to give rise to a reduction of the effective mobility of halo MOSFETs. However, further decrease of the effective mobility can be observed in pocket implanted MOSFETs above the mobility reduction due to the Coulomb impurity scattering and the gate bias dependency of the effective mobility can also differ from the simple model describing the mobility behavior in terms of the effective impurity. Phonon scattering and surface scattering as well as impurity Coulomb scattering are also shown to be effective in the degradation of the carrier mobility of pocket implanted MOSFETs. Using the 1-D regional approximation the effect of the distribution of the inversion charge density along the channel on the drain current is investigated. The inhomogeneous channel charge distribution due to pocket implantation is also shown to contribute to the further reduction of the effective mobility in halo MOSFETs.

Joining of $\textrm{ZrO}_2$/Na $\beta$"-Alumina to $\alpha$-Alumina using Aluminoborate Glass Sealant (Aluminoborate계 유리질을 사용한 $\textrm{ZrO}_2$/Na $\beta$"-알루미나 복합재와 $\alpha$-알루미나간의 접합)

  • Park, Sang-Myeon;Choe, Gi-Yong;Park, Jeong-Yong;Kim, Gyeong-Heum
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.35-41
    • /
    • 1999
  • In this study we investigated the effects of process variables on the bond strength, and its dependency upon the interfacial chemistry when the joined $ZrO_2$ toughened $Na\beta$"-alumina to $\alpha$-alumina using B$_2$$O_3$-$SiO_2$-Al$_2$$O_3$-CaO glass sealant. We observed that bond strength is mainly determined by the strength of the glass, which, in turn, depends on the glass composition established after joining reaction. Joining at $950^{\circ}C$ for 15min yielded the highest average bond strength of 66MPa. Different types of interfacial reaction seem to occur at each interface. After joining at $950^{\circ}C$ for 15min we found that Ca and Si diffuse much deeper(~15$\mu\textrm{m}$) into the $\beta$"-alumina composite than into the $\alpha$-alumina(<1$\mu\textrm{m}$) as a result of ion exchange reaction and more effective grain boundary diffusion. Thermal expansion coefficient of the glass was found to have changed more closely to those of the $\beta$"-alumina composite and $\alpha$-alumina, which put the glass under a slight compressive stress.ressive stress.

  • PDF

Analysis on Changes in Strength, Chloride Diffusion, and Passed Charges in Normal Concrete Considering Ages and Mix Proportions (재령 및 배합특성을 고려한 보통 콘크리트의 강도, 염화물 확산계수, 통과전하량 변화 분석)

  • Lee, Hack-Soo;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Concrete behavior in early-age is changing due to hydration reaction with time, and a resistance to chloride attack and strength development are different characterized. In the present work, changing strength and resistance to chloride attack are evaluated with ages from 28 days to 6 months. For the purpose, strength, diffusion coefficient, and passed charge are evaluated for normal concrete with 3 different mix proportions considering 28-day and 6-month curing conditions. With increasing concrete age, the changing ratio of strength falls on the level of 135.3~138.3%, while diffusion coefficient and passed charge shows 41.8%~51.1% and 53.6%~70.0%, respectively. The results of chloride diffusion coefficient and passed charge show relatively similar changing ratios since they are much dependent on the chloride migration velocity in electrical field. The changing ratios in chloride behaviors are evaluated to be much larger than those in compressive strength since the ion transport mechanism is proportional to not porosity but square of porosity.

A Microfluidic Electrochemical Sensor for Detecting the Very Low Concentration Endocrine Disruptor with Self Assembled Monolayer and Preconcentration Technique (자기조립단층과 농축 기술을 이용한 저농도 내분비계 장애물질 검출용 미소유체채널 기반 전기화학 센서)

  • Kim, Suyun;Han, Ji-Hoon;Pak, James Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.628-634
    • /
    • 2016
  • This paper demonstrates a microfluidic electrochemical sensor for detecting endocrine disruptor such as estradiol at a very low concentration by using preconcentration technique. In addition, self-assembled monolayer(SAM) was also employed on the working electrode of the electrochemical sensor in order to increase the estradiol capture efficiency of the sensor. SAM treatment on the working electrode enhanced the specific binding between the surface of the working electrode and the estradiol antibody. The estradiol antibody was applied on the working electrode at different concentrations(10, 20, 50, 100, 200 pg/ml) for observing the concentration dependency. The measured electrochemical redox current changed with the amount of the bound estradiol on the Au working electrode surface and the sensor can detect all the target material when the immobilized antibody amount is more than the estradiol amount in the water. The elecrochemical estradiol sensor without SAM treatment showed a low current of 7.79 nA, while the sensor treated with SAM resulted in 339 nA at 200 pg/ml, which is more than 40 fold higher output current. When combining the preconcentration technique and the SAM-treated electrode, the measured current became more than 100 fold higher than that of the sensor without neither SAM treatment nor preconcentration technique. The combination of these two techniques can would enable the proposed microfluidic electrochemical sensor to detect a very low concentration endocrine disruptor.

A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room (엑스선 촬영실의 공간산란선 발생 인자에 관한 연구)

  • Na, Soo-Kyung;Han, Sang-Hyo
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.393-399
    • /
    • 2009
  • In this study, we measured the dose distribution of scattered ray in X-ray radiography room using an ion chamber and examined the dependency of scattered ray content on the scattered ray source and exposure condition. To study the factors of scattered ray occurrence in the acryl phantom, we measured the change in the scatted ray content according to the X-ray tube voltage (40~140 kV) and the field size ($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$). For the $35{\times}35\;cm^2$ field size, the side-scattering rate ranged from 3.1% to 14.5%. The scattered ray contributions of the phantom, collimator, X-ray tube and wall were also measured. The scattered ray contribution of the phantom was higher than 95.4% for the entire tube voltage, and those of the collimator, X-ray tube and wall were 2.6%, 1.3% and 0.7%, respectively.

  • PDF

Properties of Slow Inward Current in the Rabbit Sinoatrial Node (토끼 동방결절에서의 완만내향전류$(i_{si})$에 관한 연구)

  • Ahn, Kwang-Pil;Lee, Young-Kyun;Earm, Yung-E;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.20 no.2
    • /
    • pp.165-174
    • /
    • 1986
  • The voltage clamp studies were undertaken to elucidate the properties of the slow inward current, $i_{si}$, in the small preparations of the rabbit sinoatrial node. The slow inward current, $i_{si}$, which is known to be responsible for the late one-third of pacemaker potential and whole range of upstroke phase of action potential was analysed with the effects of isoprenaline, cobalt, ouabain and higenamine. The results obtained are as follows; 1) Voltage of SA node preparation was held at zero current level, usually-40mV and the slow inward current, $i_{si}$, was activated by depolarizing clamp pulses. Peak values of $i_{si}$, in steady state were at $-10{\pm}0mV$ in most preparations. 2) Isoprenaline, ${\beta}-agonist$ increased $i_{si}$ and no shift was noticed in voltage-dependency. 3) Cobalt ion in the concentration of 1 mM abolished is, in entire range of membrane potential and the difference of two current levels before and after $Co^{2+}$ treatment could be considered as pure $i_{si}$ magnitude. 4) In the therapeutic concentration of ouabain $(5{\times}10^{-8}M)$ slightly increased is, and reduced the time to reach the peak value. 5) Higenamine $(10^{-6}M)$ changed the configurations of action potential (i. e. rapid upstroke phase and notch in the spike) and increase spontaneous rate. It also increased is, and the effect of higenamine was blocked ${\beta}-blocker$, propranolol $(10^{-6}M)$.

  • PDF