• Title/Summary/Keyword: ion concentration

Search Result 2,974, Processing Time 0.028 seconds

An Experimental Study on Evaluation of Coefficient of Chloride Diffusion by Electrochemical Accelerated Test in Concrete (전기화학적 촉진법에 의한 콘크리트의 염화물이온 확산계수 평가에 관한 실험적 연구)

  • 조봉석;김갑수;김재환;김용로;권영진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.705-710
    • /
    • 2003
  • In this study, to confirm the diffusion coefficient of chloride ion is affected by the concentration of NaCl solution, capacity of voltage, time of an electric current, the diffusion coefficient of chloride ion in concrete was investigated through an electrochemical accelerated test. and the results of these test were compared with the diffusion coefficient of chloride ion by test of sodium chloride solution digestion. As the results of this study, the diffusion coefficient of chloride ion wasn't affected by the concentration of NaCl solution, capacity of voltage, time of an electric current within the range of this study and was similar to the diffusion coefficient of chloride ion by test of sodium chloride solution digestion.

  • PDF

The Study for the Sequestration of $Ca^{2+}$ by the Micelle Colloid of Nonionic Sunactants (비이온성 계면활성제의 미셀 콜로이드에 의한 $Ca^{2+}$의 은폐에 대한 연구)

  • 권오윤;백우현
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.69-76
    • /
    • 1992
  • The effects of $Ca_{2+}$ ion on the formation of micelle colloid of nonionic surfactants, nonylphenol-(ethylene oxide)n [NP-(EO)n: n= 11, 40, 100) were investigated by the iodine solubilization method. The characteristics of spectra depended on the concentration of $Ca_{2+}$ ion and the number of EO unit. Above CMC(critical micelle concentration), the intensity of the CT (charge transfer) band by the addition of $Ca_{2+}$ ion for the NP-(EO)11 and NP-(EO)40 increased and when decreased and for the NP-(EO)In continuously increased. The increase in the intensity of CT band were attributed to the compactness of micelle in the presence of $Ca_{2+}$ ion. These phenomena may be explained by the fact that the linear ethylene oxide (EO) chain, relatively free to assume various configuration in aqueous solution, could form a pseudo-crown ether structures capable of forming complexes with $Ca_{2+}$ ion.

  • PDF

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

Environmental and biological monitoring of workers exposed to methyl bromide through quarantine fumigation (방역작업자의 브롬화메틸(methyl bromide) 노출수준과 생물학적 모니터링)

  • Lee, Jong-Seong;Lee, Yong-Hag;Shin, Jae-Hoon;Choi, Jung-Keun;O, Cha-Jae;Jung, Ho-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.212-218
    • /
    • 2001
  • This study was performed to estimate environmental and biological monitoring of workers exposed to methyl bromide through quarantine fumigation. Airborne methyl bromide and it's metabolites were analyzed by gas chromatography and ion chromatography, respectively. The results are as followings; airborne concentration of methyl bromide(TWA) was $2.08{\pm}1.56ppm$(N=8). Dispersion and setting/degas groups were $0.67{\pm}0.12ppm$(N=2) and $2.54{\pm}1.53ppm$(N=6), respectively. Bromide ion concentration in serum was $23.40{\pm}14.91mg/{\ell}$(N=10) in the exposed workers and $4.74{\pm}0.82mg/{\ell}$(N=21) in the non-exposed workers. Bromide ion concentration in urine was $35.56{\pm}26.89mg/{\ell}$(N=11) in exposed group and $6.62{\pm}2.31mg/{\ell}$(N=21) in non-exposed group. Good correlation was observed between concentration of serum and urine ($r^2$=0.890 p<0.01). No significant correlations of other determinants were observed. Calculated from a regressive curve, the biological half lifes of serum and urine were 10.7 and 5.9 days. In these results, biological monitoring of bromide ion of serum and urine provided useful information for evaluating exposure of workers to methyl bromide, so that an availability of bromide ion of biological samples was showed as biological monitoring indices for methyl bromide.

  • PDF

Effects of Eu3+ Concentration on the Photoluminescence Properties of Y1-xPO4:Eux3+ Red Phosphor (Eu3+ 함량비가 Y1-xPO4:Eux3+ 적색 형광체의 발광 특성에 미치는 영향)

  • Cho, Seon-Woog;Cho, Shin-Ho
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.430-435
    • /
    • 2011
  • $Y_{1-x}PO_4:{Eu_x}^{3+}$ red phosphors were synthesized with changing the concentration of $Eu^{3+}$ ion by using a solid-state reaction method. The crystal structures of all the red phosphors were found to be a tetragonal system composed of (200) diffraction peak centered at $25.88^{\circ}$, and the morphology of grains approached the spherical form with homeogenous size distribution as the concentration of $Eu^{3+}$ ion increased. As for the photoluminescence properties, all of the ceramic phosphors, irrespective of $Eu^{3+}$ ion concentration, showed the red-orange and the red emission peaked at 593.0 and 619.2 nm respectively. As the concentration of $Eu^{3+}$ ion increased, the excitation spectrum moved into a longer wavelength with the increase of emission intensity. The maximum excitation and the emission spectrum were observed at 0.15 mol of $Eu^{3+}$ ion.

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

Ion Exchange Characteristics of Novel HDBPDA and Dowex Ion Exchange Resins (새로운 HDBPDA와 Dowex 이온교환수지의 이온교환 특성)

  • Kim, Dong Won;Kim, Chang Suk;Choi, Ki Young;Jeon, Young Shin;Jeong, Young Kyu;Yoon, Yeo Hag;Hon, Choon Pyo
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.463-469
    • /
    • 1993
  • HDBPDA ion exchange resin, {(4, 5) : (13, 14)-Dibenzo-6, 9, 12-trioxa-3, 15, 21, -triazabicyclo [15. 3. 1]heneicosa-(1, 17, 19)(18, 20, 21) triene ion exchange resin : HDBPDA ion exchange resin} had a capacity of 3.8meq/g dry resin. The distribution coefficients of alkali and alkaline earth metal ions on HDBPDA and strongly acidic cation exchange resin, Dowex 50W-X8(200-400mesh) in water, and the various concentrations of hydrochloric acid were determined. Concentration of hydrochloric acid have almost not influenced on the distribution coefficients of alkali and alkaline earth metal ions for the HDBPDA ion exchange resin, but generally the distribution coefficient slightly increased with decreasing concentration of hydrochloric acid. The distribution coefficients of metal ions in water are larger than those in various hydrochloric acid concentration. The distribution coefficients of alkali and alkaline earth metal ions for the Dowex 50W-X8 ion exchange resin increased with decreasing hydrochloric acid concentration. Especially, the distribution coefficients of alkaline earth metal ions increased rapidly compared to those for alkali metal ions. The distribution coefficients of alkali and alkaline earth metal ions on HDBPDA ion exchange resin increased in a linear manner with decreasing acid concentration, and the slope, d log Kd/d log $M_{HCl}$ is about -0.2. Of the distribution cofficients of alkali metal ions on Dowex 50W-X8, at range of moderate hydrochloric acid concentration, the slope is about -1, while the slope for alkaline earth metal ions is about -2. However, at very low hydrochloric acid concentration, the linear variation between distribution coefficient and acid concentration was not occurred, but the slope was deviated from above values at low acid concentration.

  • PDF

Effect of Magnesium Ion in the Culture Medium on the Development of Preimplantation Mouse Embryos In Vitro (배양액 내의 마그네슘 이온이 생쥐 초기 배아 발생에 미치는 영향)

  • Choi, Soo-Jin;Jun, Jin-Hyun;Park, Yong-Seog;Bae, In-Ha
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.3
    • /
    • pp.199-207
    • /
    • 2001
  • Objective: The present study was undertaken to examine the effects of magnesium ion in the culture medium on the development of mouse fertilized oocytes either before or after pronuclear formation, and to investigate whether the effect of magnesium ion is related with the redistributional change of mitochondria. Methods : Fertilized oocytes obtained from the oviducts of mice at 15 hr after hCG injection before pronuclear formation (pre-PN) or 21 hr after hCG injection after pronuclear formation (post-PN) were used. The embryos were cultured for 3 days with basic T6 medium-magnesium free and various concentrations of magnesium ion, 0.0, 0.5, 1.0, 2.0, 4.0 or 8.0 mM, respectively. After culture, the developmental stages of embryos and the number of nuclei were evaluated. To observe the effects of magnesium ion on the mitochondrial distribution, fertilized oocytes were collected at 21 hr after hCG injection and cultured for 6 hr with various concentration of magnesium ion. As a control, fertilized oocytes with pronuclei at 27 hr after hCG injection were used. Results: The concentration of magnesium ion to accelerate the in vitro development of mouse fertilized oocytes appeared to be at 2.0 mM for the pre-PN and the post-PN stage embryos. In the mitochondrial redistribution patterns, the embryos cultured in 2.0 mM concentration of magnesium ion showed the highest percentage (22.6%) of distinct perinuclear clustering pattern comparing to other experimental group. Conclusion: The effect of magnesium ion may be related to the cytoplasmic redistribution of mitochondria. This relationship seems to connect the developmental competence of preimplantation mouse embryos in vitro. These results can suggest that higher concentration of magnesium ion (2.0 mM) than those of conventional culture medium ($0.2{\sim}1.2\;mM$) is more suitable for in vitro culture of preimplantation mouse embryos.

  • PDF

Studies on the Preparation of the Poly(vinyl alcohol) ion Exchange Membranes for Direct Methanol Fuel cell (폴리비닐알콜을 이용한 직접메탄을 연료전지용 이온교환막 제조에 관한 연구)

  • 임지원;천세원;전지현;남상용
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.191-199
    • /
    • 2003
  • Cation exchange polymer electrolyte membrane for the application of direct methanol fuel cell (DMFC) was studied. Poly(vinyl alcohol)(PVA) well known as a methanol barrier in pervaporation separation was used fur the base materials and poly(acrylic acid)(PAA) was used for the crosslinking agent with various concentration. Methanol permeability, ion conductivity, ion exchange capacity, water contents and fixed ion concentration of the membranes were investigated to evaluate the performance of the fuel cell electrolyte membrane. Methanol permeability and ion conductivity of the membranes were decreased with increasing PAA content and were increased over 15% of PAA content. These phenomena would be explained with the introduction of hydrophilic crosslinking agent. The membranes with 15% content of PAA showed methanol permeability of $6.49{\times}10^{-8}/cm^2/s,\; 2.85{\times}10^{-7}CM^2/s$ at $25^{\circ}C,\; 50^{\circ}C$ of operating temperatures, respectively. ion conductivities of the membrane were $2.66{\times}10^{-3}\;S/cm,$ $9.16{\times}10^{-3}\;S/cm$ at $25^{\circ}C,\; 50^{\circ}C$ of operating temperatures, respectively. ion exchange capacity, water content and fixed ion concentration of the membrane were revealed 1.32 meq/g membrane,0.25 g $H_2$O/g membrane and 5.25 meq/g $H_2O$, respectively.

Influence of Cement Type on the Diffusion Characteristics of Chloride Ion in Concrete (콘크리트의 염소이온 확산특성에 미치는 시멘트 종류의 영향)

  • Park, Jae-Im;Bae, Su-Ho;Lee, Kwang-Myong;Kim, Jee-Sang;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.573-576
    • /
    • 2006
  • To predict service life of concrete structures exposed to chloride attack, surface chloride concentration, diffusion coefficient of chloride ion, and chloride corrosion threshold value in concrete, are used as important factors. of these, as the diffusion coefficient of chloride ion for concrete is strongly influenced by concrete quality and environmental conditions of structures and may significantly change the service life of structures, it is considered as the most important factor for service life prediction. The qualitative factors affecting the penetration and diffusion of chloride ion into concrete are water-binder(W/B) ratio, age, cement type and constituents, chloride ion concentration of given environment, wet and dry conditions, etc. In this paper the influence of cement type on the diffusion characteristics of chloride ion in concrete was investigated through the chloride ion diffusion test. For this purpose, the diffusion characteristics in concrete with cement type such as ordinary portland cement(OPC), binary blended cement(BBC), and ternary blended cement(TBC) were estimated for the concrete with W/B ratios of 32% and 38%, respectively. It was observed from the test that the difussion characteristics of BBC containing OPC and ground granulated blast-furnace slag was found to be most excellent of the cement type used in this study.

  • PDF