• Title/Summary/Keyword: ion composition

Search Result 789, Processing Time 0.026 seconds

Fabrication of Ion Mass Analyzer and its Operational Characteristics (이온질량분석기의 제작과 그 동작특성)

  • Kim, Guang-Hoon;Choi, Young-Wook;Lee, Hong-Sik;Rim, Geun-Hie;Nikiforov, S.A.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.401-408
    • /
    • 2001
  • The information of the ion composition in plasma applications is required to characterize a plasma. A better understanding of ion species composition ratio and its spacial distribution, etc. is thus necessary in plasma-related processes, such as thin film deposition, plasma-based ion implantation, semiconductor processing, and so on. In this research, a compact ion mass analyzer that is based on magnetic sector analyzer was developed and its operational characteristics were studied in nitrogen plasma.

  • PDF

Role of Energy and Composition of Film-Forming Species in Formation of Composition and Structure of Compound Films

  • Shaginyan, L.R.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.455-464
    • /
    • 2001
  • Effect of bombardment of the growing film by energetic particles on its properties is know over many years and is widely used for modification of the film properties. Despite of this there are no final answers on such questions as: what is the mechanism of compositional changes that take place for some compound films deposited under the ion bombardment, how the ion bombardment influences the epitaxial growth, what mechanisms govern the growth of the film on its early stages during deposition under the ion bombardment. The role of composition of film-forming species in formation of film structure is barely investigated or even not investigated at all. Experimental evidence and discussion of the influence of ion bombardment and composition of film-forming species on structure and composition of compound films are briefly considered in the review.

  • PDF

A Study on Equipment and Space Composition of Heavy Ion Therapy Center (중입자치료센터의 장비 및 공간 구성에 관한 연구)

  • Hong, chang pyo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.4
    • /
    • pp.7-14
    • /
    • 2020
  • Purpose: The purpose of this study is to provide basic information for the establishment of a Heavy Ion Therapy center by analyzing the cases of Heavy Ion Therapy devices, introducing the equipment and space composition of Heavy Ion Therapy equipments. Methods: This study is carried out by study the Heavy Ion Therapy, by figure out status of the installation of treatment centers around the world and by analyze the composition of Heavy Ion Therapy equipments and spaces through case studies. Results: The results of this study, which investigated the treatment of Heavy Ion Therapy and analyzed the plans of the five Heavy Ion Therapy centers, are summarized as follows. 1) Heavy Ion equipment requires a significant floor area. Vertical as well, many cross-sectional areas need to be secured for the construction of a delivery system. The Heavy Ion Therapy device should be built as a shielded wall because of the radiation leaking. Therefore, it is necessary to consist of a independent treatment center. 2) The size of Heavy Ion devices is getting smaller. Linac can be put into syncrotron. and the size of syncrotron, delivery system, and rotating-gantry is getting smaller. 3) Japan is often installed for treatment, and control rooms are integrated, while Europe has secured research space and each control room is separated. Implications: People are not familiar with the Heavy Ion Therapy. And the effectiveness of the treatment is not well promoted yet. Hopefully, more attention will be paid to the research involved in the Heavy Ion Therapy.

Evaluation of Toxicity Influenced by Ion Imbalance in Wastewater (폐수에서 이온불균형문제가 생태독성에 미치는 영향 평가)

  • Shin, Kisik;Kim, Jongmin;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.77-83
    • /
    • 2018
  • This paper aims to evaluate the results of toxicity testing with Daphnia magna and Vibrio fischeri on wastewater samples which might be influenced by ion imbalance. The effluents from factories were found to be more toxic with high salinity levels than those from public wastewater treatment plant (WTP) and sewage treatment plant (SWP). Clion composition was highest in the effluent, in terms of percentage, which was followed by $Na^+$, $SO_4^{2-}$ and $Ca^{2+}$. $K^+$ and $Mg^{2+}$ ion was relatively low. The sensitivity of D. magna test results was higher than V. fischeri. Among samples which were proved by V. fischeri testing to be nontoxic, the composition ratio of each ion whether toxic samples or nontoxic samples which were decided by D. magna toxicity testing, were compared. $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ ion composition ratio showed high level in nontoxic samples whereas $SO_4^{2-}$ and $Cl^-$ ion composition ratio was high in toxic samples. Accordingly, $SO_4^{2-}$ and $Cl^-$ ion seemed to be considered the ions causing toxicity in effluent. Toxicity from some categories of industries (Mining of non-metallic minerals, Manufacture of basic organic petrochemicals, Manufacture of other basic organic chemicals, Manufacture of other chemical products etc.) seemed to be influenced by salinity. The Ion concentration in influent and effluent were similar. Concentration of $Na^+$, $Cl^-$, $K^+$, $Ca^{2+}$ ions were high in influent, however $Mg^{2+}$ and $SO_4^{2-}$ ions were high in effluent.

Ionic Composition of Early and Succeeding Rainwater in Pusan Area (부산시 일부지역에 대한 초기 및 후속강우의 이온성분 특성)

  • 최금찬;김찬환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.361-368
    • /
    • 1998
  • Acid rainwater samples were collected during 4 years from 1992 in Pusan area nearby seaside. Ionic composition of early and succeeding rainwater were investigated to identify emission sources. pH and Electronic Conductivity of samples were measured immediately after sampling. Major ion concentrations of rain samples were Na+, Ca2+, Mg2+, K+, NH4+, SO42-, NO3-, Cl- which were analyzed by ion Chromatography. 55% of early rainwater and 90% of succeeding rainwater were identified below pH 5.6. Because, Na+, K+, Ca2+ were washed mostly in early rainwater, as a result, pH values were increased by increasing rainfall amounts. It was studied that pH value was varied from ambient ion component, rainfall, and rain intensity. From the principal component analysis result, the dominant components of acid rainwater were Na+, K2+, Mg2+, Ca2+, the elements were contributed soil and marine source, the second components nuts -SO42-, SO4a-, NO3-, nuts -Ca2+ originated from man - made source.

  • PDF

Preparation of Coated-Wire Nitrate Ion Selective Electrode and its Application for Environmental Analysis (질산이온 선택성 피복선 전극의 제작 및 환경분석에의 응용)

  • 李龍根;金昌圭;朴廷泰;金京燮;黃圭子
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.99-107
    • /
    • 1985
  • A coated wire ion selective electrode for nitrate (nitrate-CWE_ was constructed using epoxy resin, ion exchanger and plasticizer as a polymer membrane. It's stility, the composition of a polymer membrane, the response characteristics, the selectivity were examined and applied to the environmental analysis. The nitrate-CWE was prepared using a copper wire, wihch was coated with epoxy resin being incorporated with the nitrate ion exchanger and plasticizer. The best composition of the polymer membrane for the nitrate-CWE was obtained by mixing epoxy resin, ion exchanger and plasticizer in the ratio of 2:1:0.4. The potential (56.3$\pm$0.5 mV) of stick form nitrate-CWE in this composition was close to that (59.2 mV) of Nernstian response. The detection limit for nitrate ion were found to the about $6 \times 10^{-5}M$ and the useful pH was 2.5 $\sim$ 10.3. Furthermore, the selectivity of iodide and perchrorate for the nitrage-CWE was also much improved compared with that for a liquid membrane nitrate electrode. The nitrate-CWE was used to determind $NO_x$ in stack gas. The results were in good agreement with those obtained either by electrode method or by the improved NEDA method within a relative error of 4.0%.

  • PDF

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

A Study on Estimation Method for Optimal Composition Rate of Hybrid ESS Using Lead-acid and Lithium-ion Batteries (연축전지와 리튬이온전지용 하이브리드 ESS의 최적구성방안에 관한 연구)

  • Park, Soo-Young;Ryu, Sang-Won;Park, Jae-Bum;Kim, Byung-Ki;Kim, Mi-Young;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.962-968
    • /
    • 2016
  • The large scaled lead-acid battery is widely used for efficient operation of the photovoltaic system in many islands. However, lithium-ion battery is now being introduced to mitigate the fluctuation of wind power and to replace lead-acid battery. Therefore, hybrid ESS(Energy Storage system) that combines lithium-ion battery with lead-acid battery is being required because lithium-ion battery is costly in present stage. Under this circumstance, this paper presents the optimal algorithm to create composition rate of hybrid ESS by considering fixed and variable costs in order to maximize advantage of each battery. With minimization of total cost including fixed and variable costs, the optimal composition rate can be calculated based on the various scenarios such as load variation, life cycle and cost trend. From simulation results, it is confirmed that the proposed algorithms are an effective tool to produce a optimal composition rate.

Layer-by-layer Composition Modulation by Ion-induced Atomic Rearrangement in Metallic Alloys

  • Kim, Byeong-Hyeon;Kim, Sang-Pil;Lee, Gwang-Ryeol;Jeong, Yong-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.359-359
    • /
    • 2010
  • Self-organized nanostructures of dots, holes or ripples produced by energetic ion bombardment have been reported in a wide variety of substrates. Ion bombardment on an alloy or compound also draws much attention because it can induce a surface composition modulation with a topographical surface structure evolution. V. B. Shenoy et al. further suggested that, in the case of alloy surfaces, the differences in the sputtering yields and surface diffusivities of the alloy components will lead to a lateral surface composition modulation [1]. In the present work, the classical molecular dynamics simulation of Ar bombardment on metallic alloys at room temperature revealed that this bombardment induces a surface composition modulation in layer-by-layer mode. In both the $Co_{0.5}Cu_{0.5}$ alloy and the CoAl B2 phase, the element of higher-sputtering yield is accumulated on the top surface layer, whereas it is depleted in lower layers. A kinetic model considering both the rearrangement and the sputtering of the substrate atoms agrees with the puzzling simulation results, which revealed that the rearrangement of the substrate atoms plays a significant role in the observed composition modulation.

  • PDF

A Study on Optimal Configuration Method of Hybrid ESS using Lead-acid and Lithium-ion Batteries for Supply of Variation Loads (변동부하 공급을 위한 하이브리드 ESS의 연축전지와 리튬이온전지의 최적구성방안에 관한 연구)

  • Rho, Dea-seok;Choi, Seong-sik;Lee, Hu-dong;Chang, Byunh-hoon;Kim, Su-yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 2016
  • The large scaled lead-acid battery is widely used for efficient operation of the photovoltaic system in many islands. However, lithium-ion battery is now being introduced to mitigate the fluctuation of wind power and to replace lead-acid battery. Therefore, hybrid ESS (Energy Storage system) that combines lithium-ion battery with lead-acid battery is being required because lithium-ion battery is costly in present stage. Under this circumstance, this paper presents the optimal algorithm to create composition rate of hybrid ESS by considering fixed and variable costs in order to maximize advantage of each battery. With minimization of total cost including fixed and variable costs, the optimal composition rate can be calculated based on the various scenarios such as load variation, life cycle and cost trend. From simulation results, it is confirmed that the proposed algorithms are an effective tool to produce a optimal composition rate.