• Title/Summary/Keyword: ion components

Search Result 582, Processing Time 0.026 seconds

Discharge Characteristics of Large-Area High-Power RF Ion Source for Neutral Beam Injector on Fusion Devices

  • Chang, Doo-Hee;Park, Min;Jeong, Seung Ho;Kim, Tae-Seong;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.241.1-241.1
    • /
    • 2014
  • The large-area high-power radio-frequency (RF) driven ion sources based on the negative hydrogen (deuterium) ion beam extraction are the major components of neutral beam injection (NBI) systems in future large-scale fusion devices such as an ITER and DEMO. Positive hydrogen (deuterium) RF ion sources were the major components of the second NBI system on ASDEX-U tokamak. A test large-area high-power RF ion source (LAHP-RaFIS) has been developed for steady-state operation at the Korea Atomic Energy Research Institute (KAERI) to extract the positive ions, which can be used for the NBI heating and current drive systems in the present fusion devices, and to extract the negative ions for negative ion-based plasma heating and for future fusion devices such as a Fusion Neutron Source and Korea-DEMO. The test RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of RF discharge. The characteristics and uniformities of the plasma parameter in the RF ion source were measured at the lowest area of the expansion bucket using two RF-compensated electrostatic probes along the direction of the short- and long-dimensions of the expansion region. The plasma parameters in the expansion region were characterized by the variation of loaded RF power (voltage) and filling gas pressure.

  • PDF

A Study on the Ion Exchange and th Chemical Stability of Na-fluor-tetrasilicic Mica by $H^+$ions (나트륨형불소 4 규소운모의 $H^+$ 이온교환 및 화학적인 안정성에 관한 연구)

  • 송종택
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.1
    • /
    • pp.35-39
    • /
    • 1985
  • Synthetic mica $NaMg_{2.5}(Si_4O_{10})F_2 (Na-TSM)$ was treated with HCl solution and H-type exchange resin to investigate the chemical stability and the ion exchange by measuring the dissolution of chemical components and the exchanged $H^+$ ion. The replacement of $Na^+$ ion occurred in contact with HCl solution and H-type ion exchange resin at the surface of Na-TSM particles reached $Na^+$ ions at maximum value of 70~80%. $Mg^{2+}$ ion of octahedral layer became to dissolve from the pH2 solution and th amount of it dissolved in-creased almost proportional to $H^+$ ion concentration from around 0.02N $H^+$ ion equilibrium concentration. The crystalline structure of Na-TSM was destructed by dissolution of Mg2+ ion in cncentrated hydrochloric acid solution and resulted silica gel precipitation.

  • PDF

Acceleration Test of Ion Migration in FR-4 PCB Plated with Sn (Sn 표면처리된 FR-4 재질 PCB에서의 이온마이그레이션 가속시험)

  • Hwang, Soon-Mi;Jung, Young-Baek;Kim, Chul-Hee;Lee, Kwan-Hun
    • Journal of Applied Reliability
    • /
    • v.12 no.3
    • /
    • pp.153-163
    • /
    • 2012
  • Recently, as a electronic components are becoming more high-density, so that electronic circuits have smaller pitches between the leads and are more vulnerable to insulation failure. And the reliability of electric insulation has become an ever important issue as device contact pitches and print patterns shrink. Ion migration occurs in highly humid environment as voltage is applied to an installed print circuit. Under highly humid and voltage applied circumstances, electronic components respond to applied voltages by electrochemical ionization of metals, and a conducting filament forms between the anode and cathode across a nonmetallic medium. This leads to short-circuit failure of the electronic component. In thesis, we study acceleration test of ion migration in FR-4 PCB plated with Sn. Voltage applied test of FR-4 PCB circuits plated with Sn was tested in the temperature and humidity environments. As a result of this test, equation of acceleration model was derived.

Variation of the Electrical Resistivity with ion Components of Pore Water in the Sand (사질토 간극수의 이온 성분들에 따른 전기비저항값의 변화)

  • Yu, Chan;Yoon, Chun-Gyeong;Lee, Young-Nam;Lee, Yong-Gil
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.185-196
    • /
    • 1999
  • A laboratory experiment was performed to examine the relationship between resistivity and ionic components in the pore water of a sand by using soil resistivity test box and STING-Rl. The resistivity measurement was performed with the concentration changes of ionic components. Also, the resistivity change was evaluated for multiple components. The results showed that the resistivity of Arsenic was less than other heavy metals. In the case of complex components, resistivity ranges depended on the resistivity of components existed in the pore water.

  • PDF

Preparation of LiFe PO4 Using Chitosan and its Cathodic Properties for Rechargeable Li-ion Batteries

  • Hong, Kyong-Soo;Yu, Seong-Mi;Ha, Myoung-Gyu;Ahn, Chang-Won;Hong, Tae-Eun;Jin, Jong-Sung;Kim, Hyun-Gyu;Jeong, Euh-Duck;Kim, Yang-Soo;Kim, Hae-Jin;Doh, Chil-Hoon;Yang, Ho-Soon;Jung, Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.8
    • /
    • pp.1719-1723
    • /
    • 2009
  • The LiFeP$O_4$ powder was synthesized by using the solid state reaction method with Fe($C_2O_4){\cdot}2H_2O,\;(NH_4)_2HPO_4,\;Li_2CO_3$, and chitosan as a carbon precursor material for a cathode of a lithium-ion battery. The chitosan added LiFePO4 powder was calcined at 350 ${^{\circ}C}$ for 5 hours and then 800 ${^{\circ}C}$ for 12 hours for the calcination. Then we calcined again at 800 ${^{\circ}C}$ for 12 hours. We characterized the synthesized compounds via the crystallinity, the valence states of iron ions, and their shapes using TGA, XRD, SEM, TEM, and XPS. We found that the synthesized powders were carbon-coated using TEM images and the iron ion is substituted from 3+ to 2+ through XPS measurements. We observed voltage characteristics and initial charge-discharge characteristics according to the C rate in LiFeP$O_4$ batteries. The obtained initial specific capacity of the chitosan added LiFeP$O_4$ powder is 110 mAh/g, which is much larger than that of LiFeP$O_4$ only powder.

A Study on the Assessment of Pollution Level of Precipitation at Kangwha, 1992 (江華地域 降水의 汚染度 評價에 關한 硏究)

  • 강공언;강병욱;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.57-68
    • /
    • 1995
  • Precipitation samples were collected by a wet-only automatic acid precipitation sampler at Kangwha island on the western coast in Korea, through January until December 1992. pH, electric conductivity and the concentrations of major water-soluble ion components such as N $H_{4}$$^{+}$, $Ca^{2+}$, $K^{+}$, $Mg^{2+}$, N $a^{+}$, N $O_{3}$$^{[-10]}$ , S $O_{4}$$^{2-}$ and C $l^{[-10]}$ were measured. From the result of checking the validity for assesment of pollution level of precipitation samples by pH using correlation analysis between pH and major components, and t-test of chemical composition between acid rain and non-acid rain, pH proved to be not satisfactory for its pillution level. A more comprehensive method is therefore required. In order to estimate the monthly analytical result of chemical composition of precipitation samples comprehensively, a cluster analysis was used among the various multivariate statistical analysis. As a result of making a cluster analysis for separating the monthly precipitation samples into homogeneous patterns by setting the concentrations of nine major water-soluble ion components as a variable, three homogeneous patterns were obtained. The first pattern was a group of months having average ion concentrations, the second a guoup of months having low ion concentration, and the third a group of months having high ion concentrations. Thus, it was indicated that the pollution level of precipitation was higher on February and lower on May, June, August and September than the other months. As a result, this analysis method could be estimated the chemical coposition of precipitation regionally as well as monthly.monthly.

  • PDF

Design of the vacuum pumping system for the KSTAR NBI device (KSTAR 중성빔 입사(NBI) 장치 배기계통 설계)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF

Understanding Ion Pump Emissions : Classification, Source Identification and Elimination of Emissions from Ion Pumps

  • Wynohrad, Tony
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.340-344
    • /
    • 2014
  • Ion pumps continue to be a staple in ultra-high vacuum (UHV) applications. Since their adoption as a primary UHV pump in the 1960's, it has been known that a variety of particles can emanate from within the ion pump and cause undesirable effects on current measurements and optics components. Historically the solution has been baffling and shielding which results in longer conductance paths to the ion pump. Those solutions can work, but require a larger pump and more vacuum plumbing to compensate for conductance losses. The first step was to fully understand the nature of the particles and their charges. Once those were characterized options for emissions reduction were evaluated. It was determined that an efficient design of shielding near the source of the particle generation site was the most cost effective solution. With a slight modification to the chamber of a small ion pump, internal shielding was developed that reduced the emissions by a factor of up to 1000 times.

Toxicity and Lectins Constituents from the Seed of Cornus officinalis (산수유(山茱萸) 종자(種子)의 독성(毒性)과 렉틴 성분(成分))

  • Chung, See-Ryun;Jeune, Kyung-Hee;Park, So-Young;Jang, Soon-Ja
    • Korean Journal of Pharmacognosy
    • /
    • v.24 no.2
    • /
    • pp.177-182
    • /
    • 1993
  • The pericarp of Cornus officinalis is well known famous medicinal drug in oriental countries. In this work, we have tried to evaluate the toxicity and also to find the lectin components from this seed. The lyophilized seed extract was lethal to experimental mouse at $250{\sim}300mg/kg$ and this toxic components were related to proteins. The lectins components were partially purified from the extract by ion exchange column chromatography. These lectins were relatively stable at temperature variations and also stable at pH $4{\sim}7$. The activity of these lectins did not inhibit by common carbohydrates molecules.

  • PDF

Reduced ion mass effects and parametric study of electron flat-top distribution formation

  • Hong, Jinhy;Lee, Ensang;Parks, George K.;Min, Kyoungwook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.118.2-118.2
    • /
    • 2012
  • In particle-in-cell (PIC) simulation studies related to ion-ion two-stream instability, a reduced ion-to-electron mass ratio is often employed to save computation time. But it was not clearly verified how electrons dynamics are coupled with the slower evolution of ion-ion interactions under the external electric field. We have studied the ion beam driven instability using a 1D electrostatic PIC code by comparing different rescaling of parameter with real ion mass from the reference simulation with reduced ion mass. As the external electric field is stronger, the excited unstable mode range was more sensitively affected by the system size with the real mass ratio than the reduced ion mass. The results show that the reduced mass ratio should be used cautiously in PIC code as the electron dynamics can modify the ion instabilities. Additionally we found the formation of electron flat-top distribution in the final saturation stage. Simulation results show that in the early phase electrostatic solitary waves are quasi-periodically formed, but later they are fully dissipated resulting in heated, flat-top distributions. New electron beam components are occasionally formed. These are a consequence of the interaction with solitary wave structures. We parametrically investigate the development of electron phase space distributions for various drift speeds of ion beams and temperature ratios between ions and electrons

  • PDF