• Title/Summary/Keyword: inverter transformer

Search Result 419, Processing Time 0.022 seconds

A Study on Analysis and Design of HVC Embedded High Frequency Transformer for Microwave Oven (Inverter 구동 Microwave Oven용 HVC 내장형 고주파변압기의 해석 및 설계에 관한 연구)

  • Park, K.H.;Cho, J.S.;Mok, H.S.;Choe, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.293-296
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect, a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, The design procedure of a novel HVC embedded high frequency transformer is proposed for down-sizing and cost reduction of Inverter-type power supply. Also, equivalent circuit mode] is derived by FEM analysis and impedance measurements. And the operation of proposed HVC embedded transformer is verified by simulations and experimental results.

  • PDF

Steady-state Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter for Cold Cathode Fluorescent Lamp (압전 변압기의 정상상태 특성과 고효율 냉 음극 방전램프용 인버터 설계)

  • Gwon, Gi-Hyeon;Im, Yeong-Cheol;Yang, Seung-Hak;Jeong, Yeong-Guk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.175-182
    • /
    • 2000
  • The back-light inverter used in the laptop computer is designed in this paper. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile of the inverter. In this paper, (1) the piezoelectric transformer (PT) is used for reducing the loss; (2) the volumes of core and winding coil are used in electromagnetic transformer, and (3) the half-bridge series parallel resonant circuit is used in the driver of the inverter. The modified PT for this paper and the equivalent circuit are supported by the simulation program. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter (지능형 보호기기 적용 태양광 인버터 성능시험)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

Analysis and Design of a Bidirectional Cycloconverter-Type High Frequency Link Inverter with Natural Commutated Phase Angle Control

  • Salam, Zainal;Lim, Nge Chee;Ayo, Shahrin Md.
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.677-687
    • /
    • 2011
  • In this paper a cycloconverter-type high frequency transformer link inverter with a reduced switch count is analyzed and designed. The proposed topology consists of an H-bridge inverter at the transformer's primary side and a cycloconverter with three bidirectional switches at the secondary. All of the switches of the cycloconverter operate in non-resonant zero voltage and zero current switching modes. To overcome a high voltage surge problem resulting from the transformer leakage inductance, phase angle control based on natural commutation is employed. The effectiveness of the proposed inverter is verified by constructing s 750W prototype. Experimentally, the inverter is able to supply a near sinusoidal output voltage with a total harmonic distortion of less than 1%. For comparison, a PSpice simulation of the inverter is also carried out. It was found that the experimental results are in very close agreement with the simulation.

3-phase IHCML inverter using common-arm (공통암 3상 IHMCL 인버터)

  • Song, S.G.;Park, S.J.;Moon, C.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.512-514
    • /
    • 2007
  • The number of transformers and the size of transformers in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm. Also, the equal-area method is used to calculate conduction angle with switching frequency equal to output fundamental frequency and it can reduce harmonics component of output voltage and switching loss. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

  • PDF

A Study on Core shape optimization to Improve The Efficiency of High Frequency Transformer for Inverter (인버터용 고주파 변압기의 효율 향상을 위한 코어 형상 최적화 설계에 대한 연구)

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of high frequency transformer in the inverter is to reduce the voltage and current stresses of switch components when it operates at the large conversion ratio. But the loss of transformer is the major contributor in the efficiency of inverter. This paper presents the method of core design to minimize the loss of transformer. The total loss of transformer is minimized by adjusting the effective cross-sectional areas of core. The component ratio of losses are compared by using the finite-element analysis.

Design and Application of CCFL Drive Inverter Transformer for LCD Backlight (LCD Backlight를 위한 CCFL 구동용 인버터 트랜스포머의 설계와 응용)

  • Cho, Sang-Ho;Han, Sang-Kyoo;Hong, Sung-Soo;SaKong, Sug-Chin;Kwon, Gi-Hyun;Lee, Hyo-Bum;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.96-102
    • /
    • 2008
  • In a large screen sized LCD-TV, a backlight system with only one cold cathode fluorescent lamp(CCFL) can not meet brightness specification. Thus, considerable numbers of CCFLs are used to meet brightness specification. In this paper, the design guide for the inverter transformer which can drive 4 CCFLs instantaneously is presented. With the presented design, the inverter transformer that guarantee identical lamp currents under the nonidentical lamp characteristic condition, can be implemented easily. The developed inverter transformer is adopted in a 42" LCD-TV backlight. The experimental results are presented to show the validity of the presented design guide.

Fabrication and Electrical Properties of Piezoelectric Inverter Module using Piezoelectric Transformer (압전변압기를 이용한 압전인버터 모듈 제작 및 전기적 특성)

  • Yoon, Jung-Rag;Lee, Chang-Bae;Woo, Byong-Chul
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.39-43
    • /
    • 2009
  • In order to develop piezoelectric inverter module for CCFL driving, Rosen-type multilayer piezoelectric transformer was fabricated. The output power and efficiency of mutilayer piezoelectric transformer according to the variation inner electrode layer were investigated. Mutilayer piezoelectric transformer was fabricated conventional mutilayer ceramic method using PZT base ceramics. Also, piezoelectric inverter module was adopted driving circuit with half-bridge type. The piezoelectric inverter module was set up with input voltage 12.5 V, switching frequency 104.3 KHz. The results showed the value of step-up ratio 100, efficiency 87% at load resistance of $100k{\Omega}$.

  • PDF

A Study on the Multi-level PV-PCS Using Cascade 3-Phase Transformer (직렬형 3상 변압기를 이용한 다중레벨 PV-PCS)

  • Kim, Ki-Seon;Song, Sung-Geun;Cho, Su-Eog;Choi, Joon-Ho;Kim, Kwang-Heon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2359-2369
    • /
    • 2009
  • The study on the multi-level inverter has been increasingly progressing to reduce the switching loss and improve the THD of output current in photovoltaic inverter. Recently, the main topics of multi-level inverter are to reduce the number of devices maintaining the power quality. Therefore, the novel topology was proposed for these problem which is composed of the isolated H-bridge multi-level inverter using the three phase low frequency transformer. The proposed multi-level inverter may not be need for a independent DC power, diode and capacitor. Specially, It has a advantage in generating high voltage source. The proposed approach is verified through simulation and experiment.