• Title/Summary/Keyword: inverter system

Search Result 2,788, Processing Time 0.039 seconds

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Design of High Speed Drive (고속 SRM 구동시스템 설계)

  • Kim, Tae-Hyoung;An, Young-Joo;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.95-98
    • /
    • 2006
  • This paper proposes high speed SRM drive system for blower with a new 4-level inverter and precise excitation position generator. For the high speed blower, a proper inverter and control method are proposed and the output characteristics are analyzed. In order to get a fast build-up and demagnetization of excitation a current, 4-level inverter system is proposed. The proposed 4-level inverter has additional charge capacitor, power switch and diode in the conventional asymmetric converter. The charged high voltage is supplied to the phase winding for fast current build-up, and demagnetization current is charged to additional capacitor of 4-level inverter. In addition, a precise excitation position generator can reduce turn-on and turn-off angle error according to sampling period of digital control system. The proposed high speed SRM drive system is verified by computer simulation and experimental result.

  • PDF

Development of AC Electric Vehicle Propulsion System (Converter/Inverter) using IPM Switching Device (IPM 스위칭 소자를 적용한 AC 전동차 추진제어장치 (Converter/Inverter) 개발)

  • Kim T. Y.;Kno A. S.;Hwang K. C.;Choi J. M.;Kim J. B.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.298-302
    • /
    • 2004
  • In this paper, AC electric vehicle propulsion system(Converter/Inverter) using high power semiconductor, UM(Intelligent Power module) is proposed. 2-Parallel operation of two PWM converter is adopted for increasing capacity of system and the VVVF inverter control is used a mixed control algorithm, where the vector control strategy at low speed region and slip-frequency control strategy at high speed region. The proposed propulsion system is verified by experimental results with a 1,350kW converter and 1,100kVA inverter with four 210kW traction motors.

  • PDF

Development of IPM Propulsion System (Converter/Inverter) for AC Electric Vehicle (교류 전동차용 IPM 주 전력변환장치(Converter/Inverter) 개발)

  • Kim T.Y;Kno A.S;Hwang K.C;Choi J.M
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1437-1443
    • /
    • 2004
  • In this paper, AC electric vehicle propulsion system(Converter/Inverter) using high power semiconductor, IPM(Intelligent Power module) is proposed. 2-Parallel operation of two PWM converter is adopted for increasing capacity of system and the VVVF inverter control is used a mixed control algorithm, where the vector control strategy at low speed region and slip-frequency control strategy at high speed region. The proposed propulsion system is verified by experimental results with a 1,350kW converter and 1.100kVA inverter with four 210kW traction motors.

  • PDF

High Pulse SCR Inverter for Utility Interactive Renewable Power Generation System (계통연계형 대체에너지 발전시스템을 위한 고펄스 SCR 인버터)

  • Jung, Jae-Hyuck;Kim, Hyun-Jung;Choi, Se-Wan;Kim, Young-Seok;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.85-89
    • /
    • 2001
  • In this paper, a new line-commutated SCR inverter for renewable power generation system is proposed. The proposed inverter system includes a 6-pulse SCR inverter and an auxiliary circuit. By the proper operation of the auxiliary circuit, the pulse number of the inverter system is increased and the output harmonic currents are reduced. Analysis, control and simulation for 24 pulse operation of the proposed scheme is presented and the experimental results will be provided in the final paper.

  • PDF

Design and verification of Bi-Directional Inverter and Converter using Zinc-Bromine Flow Battery (Zinc - Bromine 플로우 배터리를 이용한 양방향 인버터 및 DC-DC 컨버터 설계 및 실증)

  • Lee, SeungJun;Cho, Younghoon;Lim, Jong-ung;Choe, Gyu-ha
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.389-390
    • /
    • 2015
  • This paper proposes renewable energy system related with flow battery system which is divided into two system, converter and inverter. The Interleaved Boost Converter circuit was used for DC - DC Converter and Full-Bridge Inverter was used for Grid connected Inverter. This paper design each system and uses methods to operate converter and inverter in high efficiency.

  • PDF

Novel Control and Design Method for Wide Stability Range of Grid Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통 연계형 인버터의 넓은 안정 영역을 갖는 새로운 제어 및 설계 기법)

  • Park, Kwon-Sik;Seo, Byung-Jun;Kim, Hak-Soo;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.440-445
    • /
    • 2018
  • This study proposes a novel control and design method for a grid-connected inverter with an LCL filter without damping. The current resonance phenomenon must be considered when designing the grid-connected inverter system with an LCL filter. Passive or active damping is used in the inverter system to reduce the resonant current. However, passive damping reduces the efficiency of the system, and active damping methods are complex. If the resonant frequency is in a specific region, then the system will be unstable. This study examines the process of stabilizing the entire region without resonant damping. The validity of the proposed method is verified through simulation and experimentation.

A filed operation characteristics and the controversial point of Photovoltaic power generation system (태양광 발전시스템의 현장 운전특성 및 문제점)

  • Koh, Kang-Hoon;Suh, Ki-Young;Lee, Hyun-Woo;Hong, Doo-Sung;Gang, Yeong-Cheol;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

The Analysis of Conduction and Switching Losses in Multi-Level Inverter System (멀티레벨 인버터 시스템의 전도손실과 스위칭손실 해석)

  • 金 兌 珍;姜 岱 旭;;玄 東 石
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.111-120
    • /
    • 2002
  • The multi-level inverter system is very promising in ac drives, when both reduced harmonic contents and high power are required. In case of multi-level inverter system, the loss of switch devices cannot be analyzed by conventional methods. The reason is that the loss of each the switch device is different from one another unlike 2-level. In this paper, a simple and accurate method of computing conduction and switching loss is proposed for multi-level inverter system. The validity of the proposed method is proven for 3-level and 4-revel diode clamped inverter system.

A Study on the Temperature Control of Vapor System Using Induction Heating (유도가열 증기발생장치의 온도제어)

  • Shin, Dae-Chul;Yoo, Jae-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.117-123
    • /
    • 2010
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. This electromagnetic induction heating technique is used high frequency inverter. By using high frequency inverter high frequency alternative current in the range of [kHz] can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. Resonant high frequency inverter make system of high capacity and high efficiency. This paper describes the temperature control of induction heating system hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 to 44[kHz].