  • This paper presents a new method for designing a ballast that can provide dimming control of an electrodeless fluorescent lamp. Frequency control of lamp power is inappropriate because the lamp coefficients such as equivalent impedance, coupling coefficient of the transformer, and plasma resistance are a function of lamp power. In this paper, the dimming is achieved by controlling the DC_Link voltage in relation to the lamp power. The DC_Link voltage is controlled by a buck converter. Simulation and experimental results of the proposed design method are presented in order to validate the proposed method.

The Development of Miniature Propelling System for Electric Brake at Extreme Low Speed (극 저속시 전기제동을 위한 축소 모형 추진시스템 개발)

  • Kim, Young-Choon;Cho, Moon-Taek;Joo, Hae-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.822-827
    • /
    • 2013
  • In this paper, how to stop a moment to experiment with stop function, electric brake type scale model propulsion system is designed and fabricated by control of the braking torque is proposed. Scale model system for motor-driven, inertial load, the structure of the load for the motor and the inverter system was constructed with two sets of converters, the actual range of the rotational speed of the vehicle DDM experiments to be able to. In Additional, observer to estimate the rotor position and speed of using resolver, and the pole at low speed, speed detection methods have been developed. As a result of this study, first, stop the moment Second, the reduction of braking torque, and how to initiate the operation of the air brake blending by using the braking, improve braking methods that only use the electric brake to stop brought.

A Study on Voltage and Switching Angle for Maximum Torque/Efficiency and Minimum Torque Ripple of SRM by using SIMULINK$^\textregistered$

  • Cha, Hyun-Rok;Seo, Jong-Yun;Yang, Hyong-yeol;Kim, Kwang-Heon;Lim, Young-Cheol;Jang, Do-Hyun
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.56-64
    • /
    • 2001
  • This paper presents the switching angle and voltage for maximizing the torque or efficiency and minimizing torque ripple of an 8/6, SRM. The approximate analysis and computer simulation determine the switching angle and voltage by using SIMULINK$^\textregistered$. This is performed as a function of the speed and torque required by the load. From the results, new three facts can be known: First, the maximum torque depends on voltage and speed depends on switching angle. The others, the maximum efficiency and minimum torque ripple relay on switching angle. We control the switching angle and voltage of and asymmetrical inverter for the SRM with one-chip micro controller.

  • PDF

High precision Automatic Voltage Regulator by using series transformer (직렬 변압기를 이용한 고정밀 자동전압조절기)

  • Zhang, Lei;Lee, Hwa-Chun;Jung, Tae-Uk;Nam, Hae-Kon;Nam, Soon-Ryul;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF

A modeling and simulation for a Small-Scaled Power Quality Compensating Equipment of Electrical Railway (전기철도용 축소형 전력품질 보상설비에 대한 모델링 및 시뮬레이션)

  • Kang, Moon-Ho;Kim, Joo-Rak;Han, Moon-Seob
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.96-102
    • /
    • 2007
  • This paper presents a study on the control of a power quality compensating equipment of electrical railway built in small-scaled to preliminary research. Because this compensating equipment is very complicated power electronics system, consisting of a scott transformer as a power source, four single phase inverters interconnected with DC-link capacitors and various electrical apparatuses, multiple controllers and control algorithms with high performance and reliability are needed. The major function of the compensating equipment is to manage reactive and active powers by using the four single phase inverters, so, the main control effort is focused on the power flow control which realized through the decoupling current control of the four inverters. Overall control system is designed with object oriented and analyzed on a Simulink window. The simulation results show that the design scheme is very effective for a complicated control system and the proposed controller has good performance.

A new flux observer based vector control in induction motors

  • Tsuji, Mineo;Li, Hanqiang;Izumi, Katsuhiro;Kobuchi, Taiki;Yamada, Eiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.708-713
    • /
    • 1994
  • A new flux observer based vector control system of an induction motor is constructed by using an observer in which the commanded stator currents are used to estimate the rotor flux. In this system, the flux observer is formulated by using a model of induction motor in a stationary coordinate system. By considering an observer of induction motor in a fixed co-ordinate system located on its secondary flux, a slip frequency controlled type of vector control system is also proposed. From these control schemes, the relation between the conventional slip frequency controlled type system and the observer based one is clarified. The steady-state error of the developed torque which is caused by the parameter change of induction motor is analyzed and discussed for the selection of observer gains. The poles of the observer error dynamics and those of the observer based vector control system are calculated analytically by neglecting the machine parameter change. In order to analyze the robust stability, a linear model of the observer based vector control system is proposed taking into account the machine parameter change. By using this model, the trajectories of the poles and zeros of the torque transfer function are computed and discussed. To test validity of the theoretical analysis, experiments are conducted by using a digital signal processor (TMS320C30) and a current controlled voltage source PWM inverter.

  • PDF

A 3.3kW Bi-directional EV Charger with V2G and V2H function (V2G-V2H 기능을 갖는 3.3kW급 전기자동차용 양방향 충전기)

  • Jung, Se-Hyung;Hong, Seok-Yong;Park, Jun-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • This paper proposes a 3.3-kW bi-directional EV charger with V2G and V2H functions. The bi-directional EV charger consists of a DC-DC converter and a DC-AC inverter. The proposed EV charger is suitable for wide battery voltage control due to the two-stage configuration of the DC-DC converter. By employing a fixed-frequency series loaded resonant converter as the isolated DC-DC converter, zero-current-switching can be achieved regardless of battery voltage variation, load variation, and power flow. A 3.3-kW prototype of the proposed EV charger has been built and verified with experiments, and indicates a maximum efficiency of 94.39% and rated efficiency of 94.23%.

Mitigation of Low Frequency AC Ripple in Single-Phase Photovoltaic Power Conditioning Systems

  • Lee, Sang-Hoey;An, Tae-Pung;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.328-333
    • /
    • 2010
  • A photovoltaic power conditioning system (PV PCS) that contains single-phase dc/ac inverters tends to draw an ac ripple current at twice the output frequency. Such a ripple current perturbs the operating points of solar cells continuously and it may reduce the efficiency of the current based maximum power point tracking technique (CMPPT). In this paper, the ripple current generation in a dc link and boost inductor is analyzed using the ac equivalent circuit of a dc/dc boost converter. A new feed-forward ripple current compensation method to incorporate a current control loop into a dc/dc converter for ripple reduction is proposed. The proposed feed-forward compensation method is verified by simulation and experimental results. These results show a 41.8 % reduction in the peak-to peak ac ripple. In addition, the dc/ac inverter control system uses an automatic voltage regulation (AVR) function to mitigate the ac ripple voltage effect in the dc link. A 3kW PV PCS prototype has been built and its experimental results are given to verify the effectiveness of the proposed method.

Boost Converter Modeling of Photovoltaic Conditioning System for MPPT ("PV Converter 모델링"을 적용한 MPPT제어기법)

  • Choi, Ju-Yeop;Choy, Ick;Song, Seung-Ho;An, Jin-Ung;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.1-13
    • /
    • 2009
  • Photovoltaic conditioning systems normally use a maximum power point tracking (MPPT) technique to deliver the highest possible power to the load continuously when variations occur in the insolation and temperature. A unique method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these points is presented through deriving small-signal model and transfer function of boost converter considering input capacitor. This paper aims at modeling boost converter including fairly large equivalent series resistance(ESR) of input reservoir capacitor by state-space-averaging method and PWM switch model and compares both methods using Bode plots. In the future, properly designed controller for compensation will be constructed in 3kw real system for maximum photovoltaic power tracking control.

Minimization of Losses in Permanent Magnet Synchronous Motors Using Neural Network

  • Eskander, Mona N.
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.220-229
    • /
    • 2002
  • In this paper, maximum efficiency operation of two types of permanent magnet synchronous motor drives, namely; surface type permanent magnet synchronous machine (SPMSM) and interior type permanent magnet synchronous motor(IPMSM), are investigated. The efficiency of both drives is maximized by minimizing copper and iron losses. Loss minimization is implemented using flux weakening. A neural network controller (NNC) is designed for each drive, to achieve loss minimization at difffrent speeds and load torque values. Data for training the NNC are obtained through off-line simulations of SPMSM and IPMSM at difffrent operating conditions. Accuracy and fast response of each NNC is proved by applying sudden changes in speed and load and tracking the UC output. The drives'efHciency obtained by flux weakening is compared with the efficiency obtained when setting the d-axis current component to zero, while varying the angle of advance "$\vartheta$" of the PWM inverter supplying the PMSM drive. Equal efficiencies are obtained at diffErent values of $\vartheta$, derived to be function of speed and load torque. A NN is also designed, and trained to vary $\vartheta$ following the derived control law. The accuracy and fast response of the NN controller is also proved.so proved.