• Title/Summary/Keyword: inverter function

Search Result 330, Processing Time 0.025 seconds

Novel Anti-islanding method using phase shift with a periodic function (주기적 위상 변동 기법을 이용한 새로운 단독운전 검출 기법)

  • Jung, Young-Seok;Choi, Jae-Ho;So, Jung-Hoon;Yu, Byung-Guy;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1153-1154
    • /
    • 2006
  • This paper proposes the optimal design method based on NDZ analysis to secure the islanding defection ability and to maintain the stability and power quality when the grid is connected. A PSiM-based model and analysis of the system is presented, specialty aimed at improving the effectiveness of phase shift anti-islanding method with frequency feedback, which causes the inverter current to be generated slightly lower or higher in frequency than the frequency of the terminal voltage. The proposed method can cause frequency jump with leading and lagging phase of output current in two line cycles. As a result, the proposed algorithm is more sensitive and reliable than the conventional phase shift method. Experimental results, on a 3 kW inverter connected to 220 V, 60 Hz utility, are discussed.

  • PDF

A Study On PIN Pulse Pattern Optimization In The Space Vector Notation Using Pulse Frequency Modulation (펄스 주파수 변조 방법을 이용한 공간 벡터 PWM 펄스 패턴최적화 기법에 관한 연구)

  • Jeon, Hi-Jong;Son, Jin-Geun;Kim, Dong-Joon;Lee, Suck-Tae;Choi, Woo-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.307-312
    • /
    • 1994
  • In this investigation the PFM(Pulse Frequency Modulation} will be used for optimizing PWM inverter pulse pattern. In traditional the pulse frequency of PWM is kept const. But modulated PWM's frequency in this study, the sinusoidal inverter's performance should be improved. The PWM pulsepatterns are definitely controlled so that the time-integral function of the voltage vectors in the space vector notation may show a circular locus. Further, performance index will be minimized because of minimizing distortion of output current. Finally, we will implement itusingsingle-chip microprocessor.

  • PDF

Novel RPWM Techniques for Three-Phase Induction Motor Drive (3상 유도전동기 구동을 위한 새로운 RPWM 기법)

  • 권수범;김남준
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.262-268
    • /
    • 2004
  • This thesis is proposing novel RPWM (Random PWM) techniques that can locate PWM pulse to do random. RPWM techniques to propose locates SVPWM (Space Vector PWM) pulse by number of each random and principle to locate of pulse applies different random function and locate pulse. For propriety verification of proposed techniques, achieve an simulation and experiment that use MATLAB/SIMULINK about proposed RPWM techniques algorithm and IGBT inverter composition that use DSP(TMS320C31). Specially, analyze harmonic spectra of inverter output current when the induction motor speed is more than 10,000 rpm, confirm that RPWM's effect in high speed degree appears. Proposed RPWM techniques propriety prove from reduction effect of harmonic magnitude that corresponds to an integer times of switching frequency.

Optimized PWM Switching Strategy for an Induction Motor Voltage Control

  • Lee, Hae-Hyung;Hwang, Seuk-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.527-533
    • /
    • 1998
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses, and has been therefor recognizedas the perfered PWM method, especially in the case of digital implementation. Three-phase invertor voltage control by space vector modulation consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The prefered switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by suing the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

  • PDF

Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller (제어기응답을 고려한 전압형 인버터의 출력 LC필터 설계)

  • Kim, Jae-Sig;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1077-1079
    • /
    • 2000
  • In this paper. the design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form. the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it can be verified how much the voltage distortion is effected when the nonlinear load is connected.

  • PDF

The development of a high efficient transcranial magnetic stimulation adopted real time-charging-discharging circuit

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we have been proposed the new type of a transcranial magnetic stimulation adopted a variable voltage capacitor with Cockcroft-Walton circuit and constant-frequency current resonant half-bridge inverter. This a transcranial magnetic stimulation has some merits compared with the conventional one. First, it doesn't require the high voltage transformer. And second, it has less switching losses, compact size and capability in adjusting the transcranial magnetic stimulation output energy precisely. In this paper, we have performed the output characteristics of a transcranial magnetic stimulation system which is well known as magnetic stimulation. The tested results are described as a function of pulse repetition rate and switching numbers of the half-bridge inverter.

The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation (병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법)

  • Kim, Dong-Kyune;Cho, Sang-Rae;Choy, Ick;Lee, Young-Kwoon;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

Control and Analysis of Operation of Current-Fed Quasi Z-Source Inverter (전류제어형 Quasi-ZSI의 동작 해석 및 제어)

  • Chun, T.W.;Vu, Ho Ahn;Lee, H.H.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.482-483
    • /
    • 2012
  • In this paper, the operation of current-fed quasi-Z-source inverter (QZSI) with buck-boost function, improved reliability, and regeneration capability is analyzed. The modified space modulation technique for controlling effectively both shoot-through time and zero voltage time is suggested. The simulation result is carried out in order to verify the performance of proposed technique.

  • PDF