• Title/Summary/Keyword: inverter driven system

Search Result 170, Processing Time 0.05 seconds

Current tracking Control type Inverter using Neural Network (신경 회로망을 이용한 전류 추종 제어형 인버터)

  • Kim, Jong-Hae;Sim, Kwang-Yeal;Bae, Sang-June;Kim, Dong-Hee;Lee, Dal-Hae
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.252-254
    • /
    • 1994
  • This paper describes the control method in order that output current of a voltage source inverter tracks reference sinusoidal current so that its harmonic current components are reduced. Operating character of this inverter is analyzed with normalized values of parameter. And the method that apply multilayed feedfoeward neural networks, which play excellent steady state operation in control system, to inverter control system and training method are presented. Then, the output current of inverter which is driven by the proposed method. is considered throughout computer simulation and safe operating range of inverter parameter is resented.

  • PDF

Inverter Controller for Escalator System (에스컬레이터용 인버터 제어장치)

  • 장철호;이근호;허재영;강동우;윤길문;신정기;이제필
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.291-294
    • /
    • 1999
  • Line starting using contactors is a conventional method for escalator system Recently, comsumer's requirements for energy saving and variable functions are increasing To satisfy this demands, LG Industrial Systems Co., Ltd. has developed an escalator which is driven by inverter system. In this paper, technical schemes of the developed escalator are introduced and the performance of the proposed system is proved by experiment.

  • PDF

Analysis and Efficiency Control of Linear Compressor System for Refrigerator Driven by PWM Inverter (PWM인버터로 구동되는 냉장고용 선형압축기시스템의 특성해석 및 효율제어)

  • Son, Jang-Kyung;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1544-1549
    • /
    • 2013
  • Recently, the linear compressors with the free piston driven by the linear motor have widely attention in the cooling apparatus such as a refrigerator due to high efficiency. The method of using triacs as a linear motor drive is not satisfactory to improve the efficiency of the linear compressor. In this paper, the performance of the linear compressor using a PWM inverter such as the efficiency is investigated with the variations of both mechanical resonant frequency and electrical resonant frequency. The control loop for controlling both the piston stroke and efficiency is suggested. Through simulation and experimental studies, the performance of both the stroke and angle controls for improving the efficiency of the linear compressor is verified.

A Study on the Rejection of A Output Leakage Current of Single Phase Induction Motor Driven a Inverter (인버터로 구동되는 단상 유도전동기의 출력 누설전류 억제 대책에 관한 연구)

  • 박찬근;박정환;최승현;이성근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.553-557
    • /
    • 2000
  • This paper proposes the method to reduce output leakage current in single phase induction motor driven a PWM inverter. A proposed method applies to a new PWM switching algorism to reduce low-order harmonic in an inverter system with a feedback circuit of leakage current. Simulation is done to confirm a validity of method Proposed.

  • PDF

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF

Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device (바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구)

  • Choi, J.M.;Kim, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

A Study on the Control of Single Phase Induction Motor by Full Bridge Series Inverter (직렬 브리지형 인버터에 의한 단상 유도전동기의 속도제어)

  • Park, Jin-Gil;Roh, Young-O;Jung, Byung-Gun;Kang, Chang-Nam;Jung, Sam-Sig
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.912-915
    • /
    • 1993
  • In this paper, the speed of single phase induction motor driven by full bridge inverter is controlled by a PID controller under condition of disturbance load and setpoint changes, and the current characteristics of the system is investigated to look for the good properties of A.C. motor torque through the results of experiment. From the experimental result, it is confirmed that the speed of single phase induction motor driven by full bridge series inverter can be smoothly controlled by an analog PID controller.

  • PDF

Torque ripple reduction in DTC of induction motor driven by 3-level inverter (3레벨 인버터로 구동되는 유도전동기 직접토크제어의 토크리플 저감법)

  • Lee, Kyo-Beum;Song, Joong-Ho;Choy, Ick;Yoo, Ji-Yoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.620-631
    • /
    • 2000
  • A torque ripple reduction technique of direct torque control(DTC) for high power induction motors driven by 3-level inverters with the inverter switching frequency limited around 0.5-1.0kHz level is presented. It is noted that conventional DTC algorithms to reduce torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. Such conventional algorithms can not accomplish satisfactory torque ripple reduction for 3-level inverter systems with lower switching frequency. A new DTC algorithm, especially for low switching frequency inverter system, illustrates relatively reduced torque ripple characteristics all over the operating speed region. Simulation and experimental results show the effectiveness of the proposed control algorithm.

  • PDF

Performance of an inverter refrigeration system with a change of expansion devices (인버터형 냉동시스템의 팽창장치 변경에 따른 성능특성)

  • 이용택;김용찬;박윤철;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.928-936
    • /
    • 1999
  • An experimental study was performed to investigate characteristics of an inverter driven water-to-water refrigeration system with a variation of compressor frequencies and expansion devices. The frequency of a compressor varied from 30Hz to 75Hz, and performance of the systems applying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve(EEV) were measured. The load conditions were altered by varying the temperature of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test conditions were deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimum control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in an inverter refrigeration system due to active control of flow area with a change of compressor frequency and load conditions.

  • PDF

Failure Case-Study and Countermeasures of High-Voltage Motor with Inverter Drive System (인버터 구동에 따른 고압전동기 사고사례와 대책)

  • Choi Young-Chan;Woo Myung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.163-166
    • /
    • 2002
  • Recently, the insulation breakdown accident has been experienced at 6.6kV inverter driving motor. That brought about the reliability degradation of motor driving system.. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the Insulation system of motor which Is driven by inverter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of Insulation breakdown accidents.

  • PDF