• Title/Summary/Keyword: inverter control system

Search Result 1,563, Processing Time 0.029 seconds

Design of a Miniature Fuse with High Breaking Capacity and Load Life Using a Ceramic Powder of Extinguishing an Electric Arc (아크 소호용 세라믹 분말을 이용한 높은 차단용량 및 고내구성을 갖는 초소형 퓨즈 설계)

  • Kang, Chang yong;Jin, Sang Jun;Lee, Ye Ji;Youn, Jae Seo;Noh, Seong yeo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.327-332
    • /
    • 2019
  • Recently, inverter control systems have attracted immense attention to increase the energy efficiency. However, such systems use repeated on/off high currents for linear operation control, instead of the prevalent step variable current control method. Hence, there arise concerns of personal and property damage, especially due to the durability, explosive characteristics, and operating speed of the fuse, which is responsible for safety and is one of the internal components using current control. Therefore, in this paper, we propose an IEC60127-4 SMD sub-miniature fuse, consisting of Ag-Cu alloys and ceramic powder for arc soothing. The IEC60127-4 SMD sub-miniature fuse has high durability and cut-off capacity, and operates safely in dangerous circumstances caused by the inverter control system.

A Study on High Performance Operation of Hybrid Energy Recovery Drive System for Piezoelectric Pump (피에조 펌프 구동용 에너지 회수형 하이브리드 구동장치 고성능 운전에 관한 연구)

  • Hong, Sun-Ki;Lee, Jung-Seop;Cho, Yong-Ho;Kim, Ki-Seok;Kang, Tae-Sam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1426-1431
    • /
    • 2015
  • Piezoelectric pump can be considered as R-C load and it needs something special driver because the output voltage does not become 0 even though the applied voltage is 0 with common converter. This operating system consists of fly-back converter to increase the input voltage and energy recovery inverter to apply square voltage to the piezoelectric pump. The energy recovery inverter can charge and discharge the energy of capacitive load. In this paper, to enhance performance of the driver, a few elements or circuits are added and modified. To drive the inverter safely, current limit resister is added and adjusted the value to valance the charging and discharging current. In addition, a current limit inductor is added to the input side to limit the input current and enhance the efficiency. Inductor only may make oscillation and another resister is added parallel to the inductor to solve this problem. The converter and inveter are assembled to one board for compactness. The appropriateness is proved with simulation and experiments.

A New Control Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 직류전압평형을 위한 새로운 제어기법)

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.179-184
    • /
    • 2005
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). A new switching scheme is developed for the SVC system. To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Advanced PWM Method for Reducing Common-Mode Noise in Converter/Inverter System (컨버터/인버터 시스템의 커먼 모드 노이즈 억제를 고려한 PWM 기법)

  • Lee, Young-Min;Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1882-1885
    • /
    • 1998
  • This paper proposes the advanced PWM method which can reduce common-mode voltage in 3 phase PWM converter/inverter system. By shifting the zero voltage vector of inverter in a sampling period, it is possible to cancel out a common-mode voltage pulse defined by switching functions of converter and inverter. Without any loss of control performance of converter/inverter system, overall common-mode voltage can be reduced by one-third compared with that of conventional PWM scheme.

  • PDF

Automatic Turn-off Angle Control for High Speed SRM Drives

  • Nashed Maged N.F.;Ohyama Kazuhiro;Aso Kenichi;Fujii Hiroaki;Uehara Hitoshi
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • This paper presents a new approach to the automatic control of the turn-off angle used to excite the Switched Reluctance Motor (SRM) employed in electric vehicles (EV). The controller selects the turn-off angle that supports and improves the performance of the motor drive system. This control scheme consisting of classical current control and speed control depends on a lookup table to take the best result of the motor. The turn-on angle of the main switches of the inverter is fixed at $0^{\circ}C$ and the turn-off angle is variable depending on the reference speed. The motor, inverter and control system are modeled in Simulink to demonstrate the operation of the system.

A Study on Cooling System for Efficiency Improvements of 3kW Outdoor Type Photovoltaic Inverter (3kW급 옥외형 태양광 인버터의 효율개선을 위한 냉각시스템 연구)

  • Kim, Min-Seok;Park, Eui-Jong;Kim, Yong-Jae;Oh, Bo-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.617-624
    • /
    • 2014
  • Recently, photovoltaic inverter is received attention in photovoltaic with introduction of feed-in tariff. However, this inverter has problems such as inability to respond flexible at climate change due to its opening, and decrease of efficiency and lifetime due to its abnormal operation. To solve the problem, we desire to develop the eco-inverter which has a temperature control to respond easily on the change of temperature, and use the sealed structure not to affect the environment. In addition, we derive the optimal position of cooling system which is placed inside of inverter to minimize the power consumption, and proposed the effective measure to improve the efficient of inverter by deciding the number of cooling system.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters (2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

The Phase Contol Method of 2-Phase Servomotor Driven with Microprocessor-based Inverter (인버어터구동 이상서어보 전동기의 마이크로프로세서에 위한 입상제어)

  • 원종수;장도현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.2
    • /
    • pp.80-87
    • /
    • 1987
  • This paper describes a new approach to control the two-phase servomotor driven with microprocessor based inverter. Conventional 6-step driving system has some shortcomings such as vibration and loss caused by the harmonic voltage. An attempt has been made to eliminate the harmonic content of output waveform by PWM technique and to simplify the control system by phase control method. In realizing the phase control by PWM technique proposed by this paper, control circuit and algorithm has been suggested. The proposed method has been applied to the speed control system with PI controller to confirm the adaptation of the servo system and experimental results has been compared with the computer simulation.

A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system (교류-직류 연계계통에 있어서 직류제어방식의 비교연구)

  • 정형환;왕용필;안병철;이광우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF