• Title/Summary/Keyword: inverse proportion

Search Result 307, Processing Time 0.04 seconds

Observation and Characteristics of Ozonizer using Injection Needle Electrode (주사바늘 전극형 오존발생기 특성 연구)

  • Park, Hyun-Mi;Kwon, Young-Hak;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

Electric Circuits Modeling of Magnetoelectric Bulk Composites in Low Frequency (ME 소자의 저주파 등가회로 모델링)

  • Chung, Su-Tae;Ryu, Ji-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.7
    • /
    • pp.515-521
    • /
    • 2013
  • Magnetoelectric(ME) bulk composites with PZT-PNN-PZN/$Fe_2O_4$ were prepared by using a conventional ceramic methods and investigated on the ME voltage vs frequency of ac magnetic fields. We made the electric equivalent circuits by using the Maxwell-Wagner model and simulated the frequency dependence of ME voltage in low frequency region. ME devices were described by a series of two equivalent circuits of piezoelectric and magnetic, which have the relaxation time ${\tau}$ due to the interaction between ME device and load resistor. Equivalent circuit of piezoelectric material is independent of frequency. However ferrite magnetic materials have Debye absorption and dipolar dispersion, whose equivalent circuit is a function of frequency. Therefore we suggest the resistance in the equivalent circuit is proportion to $1+{\omega}^2{\tau}^2$ and the capacitance is in inverse proportion to $1+{\omega}^2{\tau}^2$ in the magnetic materials.

Radiographic Evaluation of Coxofemoral Joints in the Jindo (Canis familiaris) (진도개의 고관절이형성에 대한 방사선학적 연구)

  • 오석일;김상기
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.467-473
    • /
    • 2003
  • The pelvic radiographs of 47 clinically normal Jindoes (26 dogs and 21 bitches) were investigated to evaluate the coxofemoral joints, prospectively. The hip joints were graded according to the Orthopedic Foundation for Animals criteria of excellent, good, fair, borderline, mild canine hip dysplasia (CHD), moderate CHD, severe CHD. Of the 47 Jindoes evaluated, 8 (17%) were graded as dysplastic, 3 (6.4%) were mildly dysplastic, 3 (6.4%) were moderately dysplastic, and 2 (4.3%) were severly dysplastic. Of the 39 Jindoes graded as normal, 16 (34%) were classified as having excellent hip joint phenotype, 15 (31.9%) were classified as having fair, and 8 (17%) were classified as good. Each hip joint was scored based on the British Veterinary Association/The Kennel Club hip scoring system. The normal hip joint (excellent, fair, good) received score less than 5, while dysplastic hip joint (mild, moderate, severe CHD) received score form 5 to 29. Norberg angle (r=0.76) and femoral angle of inclination (r=0.6) were in inverse proportion to grade of the hip joint (P<0.01). The width of medial joint space was in proportion to grade of hip joint (r=0.7, P<0.01).

Evaluation of Absorbed Dose According to Nanoparticle Density During the Breast Cancer Brachytherapy (유방암 근접치료 시 나노입자의 밀도에 따른 흡수선량 평가)

  • Lee, Deuk-Hee;Nam, Ji-Hee;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.131-135
    • /
    • 2019
  • The purpose of this study was to evaluate the efficacy of brachytherapy of breast cancer by dose assessment which a steady increased in Korea women. The dose assessment was performed using the MCNPX program, a MonteCarlo simulation technique. The sources used for brachytherapy was 192Ir. And nanoparticle which used for dose enhancement was gold. The density of nanoparticle was 7, 18 and 30 mg. Evaluation of absorbed dose according to distance is measured at a distance of 30, 50, 100 and 200 cm from the patient. As a result, The breast absorbed dose results increased in proportion to the density of nanoparticle. And the surrounding organs were not significantly different according to the density. But, in some organs, the absorbed dose decreased as the density of nanoparticles increased. Absorbed dose according to the distance was in inverse proportion to distance.

Fast transport with wall slippage

  • Tang, Zhipeng;Zhang, Yongbin
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.37-41
    • /
    • 2021
  • This paper presents the multiscale calculation results of the very fast volume transport in micro/nano cylindrical tubes with the wall slippage. There simultaneously occurs the adsorbed layer flow and the intermediate continuum fluid flow which are respectively on different scales. The modeled fluid is water and the tube wall is somewhat hydrophobic. The calculation shows that the power loss on the tube no more than 1.0 Watt/m can generate the wall slippage even if the fluid-tube wall interfacial shear strength is 1 MPa; The power loss on the scale 104 Watt/m produces the volume flow rate through the tube more than one hundred times higher than the classical hydrodynamic theory calculation even if the fluid-tube wall interfacial shear strength is 1 MPa. When the wall slippage occurs, the volume flow rate through the tube is in direct proportion to the power loss on the tube but in inverse proportion to the fluid-tube wall interfacial shear strength. For low interfacial shear strengths such as no more than 1 kPa, the transport in the tube appears very fast with the magnitude more than 4 orders higher than the classical calculation if the power loss on the tube is on the scale 104 Watt/m.

Determinants of Health Care Expenditures and the Contribution of Associated Factors: 16 Cities and Provinces in Korea, 2003-2010

  • Han, Kimyoung;Cho, Minho;Chun, Kihong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.6
    • /
    • pp.300-308
    • /
    • 2013
  • Objectives: The purpose of this study was to classify determinants of cost increases into two categories, negotiable factors and non-negotiable factors, in order to identify the determinants of health care expenditure increases and to clarify the contribution of associated factors selected based on a literature review. Methods: The data in this analysis was from the statistical yearbooks of National Health Insurance Service, the Economic Index from Statistics Korea and regional statistical yearbooks. The unit of analysis was the annual growth rate of variables of 16 cities and provinces from 2003 to 2010. First, multiple regression was used to identify the determinants of health care expenditures. We then used hierarchical multiple regression to calculate the contribution of associated factors. The changes of coefficients ($R^2$) of predictors, which were entered into this analysis step by step based on the empirical evidence of the investigator could explain the contribution of predictors to increased medical cost. Results: Health spending was mainly associated with the proportion of the elderly population, but the Medicare Economic Index (MEI) showed an inverse association. The contribution of predictors was as follows: the proportion of elderly in the population (22.4%), gross domestic product (GDP) per capita (4.5%), MEI (-12%), and other predictors (less than 1%). Conclusions: As Baby Boomers enter retirement, an increasing proportion of the population aged 65 and over and the GDP will continue to increase, thus accelerating the inflation of health care expenditures and precipitating a crisis in the health insurance system. Policy makers should consider providing comprehensive health services by an accountable care organization to achieve cost savings while ensuring high-quality care.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Analysis of Species Composition and Communities of Phytoplankton through Marine Environmental Factors in the Coastal Water of Baegyado Island during Winter (백야도 연안의 동계 해양환경 특성에 따른 식물플랑크톤의 종조성과 군집 분석)

  • Kim, Mi-Kyung;Park, Jung-Won
    • ALGAE
    • /
    • v.19 no.3
    • /
    • pp.247-255
    • /
    • 2004
  • This study was to clarify the variations in a marine ecosystem through examining the species composition of phytoplankton in the coastal water of Baegyado Island during winter. Water temperature, salinity, SS, NH$_4$-N, NO$_2$-N, NO$_3$-N and SiO$_2$-Si were significantly different and in inverse proportion to the chlorophyll a and species number according to stations and water depth. The total number of species was 88, composed of 94% Bacillariophyceae, 3.4% Chrysophyceae, 2.2% Dinophyceae and 1.1% Euglenophyceae. The dominant species were Rhizosolenia setigera, Skeletonema costatum and Stephanopyxis palmeriana. The maximum of standing crops was $5,450cells{\cdot}ml^(-1)$, while the minimum was $1,700cells{\cdot}ml^(-1)$. The coastal water was influenced with two water bodies which had characteristics of low water temperature - low salinity and high water temperature - high salinity.

Instantaneous Following Control of Half-Bridge DC-DC Converter (하프브리지 DC-DC 컨버터의 순시추종제어)

  • Ra B.H.;Lee H.W.;Kim S.D.;Kim K.T.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.54-57
    • /
    • 2003
  • A new non linear, mean value, instantaneous following control technique to design half bridge converter is proposed in witch control principle uses characteristic that reset time of analog integrator is inverse proportion In input voltage. It is Important characteristic that compensation and follow-up control time are same with switching frequency. Is completed in one cycle that base control frequency. Have excellence characteristic that follow in order instruction value exactly stationary state as well as transient state. Half bridge converter that apply this control principle can know that have stabilize and excellence characteristic. This technique is verified through an experiment, and know that experiment result and theory agree well.

  • PDF

Experimental Investigation and Performance Test of Heavy Duty Torque Converter (중부하 토크 컨버터의 실험적 성능분석)

  • Lee, Hae-Jong;kim, Se-Hyun;Lee, Chung-Seub;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.690-695
    • /
    • 2004
  • The present study is an investigation on the characteristics of heavy load toque converter by experimental process. To get the dynamic performance, the dynamometer was used with a parameters of speed, torque, oil pressure and oil flux, etc. The torque converter was tested for various input speed, output oil pressure and input oil flow rate. All experiments were investigated in case that the speed ratio is increased. The torque ratio and capacity factor was in inverse proportion to speed. Engine revolution had a more effects at region of low speed ratio. But, the opposite phenomena were represented increase of efficiency. In result of this experiments, the characteristics of torque converter were not influenced by oil pressure and oil flux.

  • PDF