• 제목/요약/키워드: intraocular lens

검색결과 36건 처리시간 0.022초

A Study of Optical Properties of Intraocular Lenses and of Measurement of the Index of Reflection for an Unknown Liquid

  • Joo, Won Don;Jung, Mee Suk
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.236-242
    • /
    • 2012
  • In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.

단백질흡착 감소용 하이드로겔의 개발 및 인공수정체로의 적용 (Development of Hydrogel for Decrease Protein Adsorption and Application to Intraocular Lens)

  • 고나영;이현미
    • 대한화학회지
    • /
    • 제62권1호
    • /
    • pp.30-35
    • /
    • 2018
  • 인공수정체로 사용되고 있는 소수성 아크릴 하이드로겔의 단백질 흡착 감소와 기능을 향상시키기 위한 하이드로겔을 제조하여 인공수정체로의 응용성을 살펴보고자 한다. 소수성 아크릴 인공수정체는 ethyleneglycol phenyletheracrylate(EGPEA), Styrene, 2-hydroxyethyl methacrylate(HEMA)를 사용하여 제작하였고 첨가제로 polyvinyl pyrrolidone(PVP)와 2-methacryloyloxyethyl phosphorylcholine(MPC)를 사용하였다. 인공수정체의 물리적 특성을 평가하기 위해 함수율, 습윤성, 광투과율 및 단백질 흡착량을 측정하였다. 첨가제를 넣은 모든 시료의 함수율과 습윤성은 증가하였고 단백질 흡착량은 감소하였다. 특히 MPC가 포함된 시료의 단백질 흡착량은 더욱 감소하였다. PVP와 MPC를 첨가한 소수성 아크릴 하이드로겔은 기본적인 물리적 특성을 가지면서 단백질 흡착을 감소시킴으로써 기능이 향상된 인공수정체로의 응용이 가능하다는 것을 확인하였다.

안내렌즈를 이용안 무수정체안의 교정원리 (The correction principle of Aphakia using the Intraocular Lens)

  • 김봉환;김대현;임현선;지택상;고정휘
    • 한국안광학회지
    • /
    • 제10권4호
    • /
    • pp.339-345
    • /
    • 2005
  • 본 논문에서는 안내렌즈를 이용하여 무수정체안을 정시로 교정하는 원리에 대하여 연구하였다. 현재 안과에서 안내렌즈를 처방하여 임상적으로 사용하고 있는 시력 교정을, 광학적으로 보다 정확한 처방을 하기 위한 방법을 제시하였다. 무수정체안을 정시로 교정하기 위해서 비정시의 두 가지 원인인 굴절성과 축성을 고려하였고, 교정원리로는 수정체 후면에서 최적 상점까지의 거리인 상측정점 초점거리(BFL)와 수정체에서 망막까지의 거리인 초자체 길이가 일치되도록 하는 것이다. 교정원리를 확인하기 위하여 정시의 경우는 Gullstrand number I 모형안을, 근시와 원시의 경우는 실안에 대한 임상자료를 사용하여 수정체를 안내렌즈로 대치하였다.

  • PDF

백내장 수술 후 수면 변화에 관한 통합적 고찰 (An Integrative Review on Alterations of Sleep after Cataract Surgery)

  • 안경주
    • Journal of Korean Biological Nursing Science
    • /
    • 제21권1호
    • /
    • pp.12-21
    • /
    • 2019
  • Purpose: The purpose of this study was to review previous literature with an aim to explore the sleep disturbance level after a patient undergoes cataract surgery using an integrative review. Methods: We used the key words, 'cataract surgery', 'sleep', and 'intraocular lens' to find peer-reviewed publications in seven databases. Among 450 searched articles, eight articles were selected after exclusion of articles that did not meet the criteria. Results: Five of the articles submitted that subjective sleep quality of the patients with blue-filtering intraocular lens (BF-IOL) implant improved as compared to that before surgery. The change of saliva melatonin concentration after BF-IOL implant did not coincide in two of the articles. Two of the articles reported an increased level of intrinsically photosensitive retinal ganglion cells response after BF-IOL implantation. Conclusion: The published studies stated that BF-IOL implant did not have any negative impact on quality of sleep among cataract patients suffering with poor sleep. Rregardless of intraocular lens type, cataract surgery may increase photoreception of intrinsically photosensitive retinal ganglion cells one year after surgery although the mechanism was not clear. It is necessary to identify various factors influencing the quality of sleep such as gender and activities among cataract patients with BF-IOL implant in the future.

Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis

  • Yoon, Chang Ho;Shin, In-Soo;Kim, Mee Kum
    • Journal of Korean Medical Science
    • /
    • 제33권44호
    • /
    • pp.275.1-275.15
    • /
    • 2018
  • Background: We compared the efficacy between trifocal and bifocal diffractive intraocular lens (IOL) implantation. Methods: Through PubMed, MEDLINE, EMBASE, and CENTRAL, we searched potentially relevant articles published from 1990 to 2018. Defocus curves, visual acuities (VAs) were measured as primary outcomes. Spectacle dependence, postoperative refraction, contrast sensitivity (CS), glare, and higher-order aberrations (HOAs) were measured as secondary outcomes. Effects were pooled using random-effects method. Results: We included 11 clinical trials, with a total of 787 eyes (395 subjects). The trifocal IOL group showed better binocular distance VA corrected with defocus levels of -0.5, -1.0, -1.5, and -2.5 diopter than the bifocal IOL group (All $P{\leq}0.004$). The trifocal IOL group showed better monocular uncorrected distance and intermediate VAs (mean difference [MD], -0.04 logarithm of the minimum angle of resolution [logMAR]; 95% confidence interval [CI], -0.07, -0.01; P = 0.006 and MD, -0.07 logMAR; 95% CI, -0.13, -0.01; P = 0.03, respectively). Postoperative refraction, glare, CS, and HOAs were not significantly different from each other. Conclusion: The overall findings indicate that trifocal diffractive IOL implantation is better than the bifocal diffractive IOL in intermediate VA, and provides similar or better in distance and near VAs without any major deterioration in the visual quality.

백내장적출술 및 인공수정체삽입술이 안압에 미치는 영향 (The Effect of Extracapsular Cataract Extraction and Posterior Chamber Lens Implantation on Intraocular Pressure)

  • 차순철;이규원
    • Journal of Yeungnam Medical Science
    • /
    • 제11권2호
    • /
    • pp.277-283
    • /
    • 1994
  • 저자들은 1993년 2월부터 1993년 4월까지 대구 제일안과의원에서 백내장낭외적출술 및 인공수정체삽입술을 받은 환자 중 백내장이외의 다른 안질환이나 전신질환이 없고 술전 양안 안압이 24mmHg이하인 환자중 편안만을 수술받은 환자 15명을 대상으로 안압의 변화를 비접촉성 안압계 및 Goldmann 압평안압계를 사용하여 3개월 이상 추적 관찰하였다. 위수정체안의 안압이 술전 안압보다 평균 $3.4{\pm}2.9mmHg$(p<0.001)의 안압하강을 나타내었으며 반대측 수정체안과의 안압차이는 평균 $2.4{\pm}3.8mmHg$(p<0.05)으로 위수정체안에서 낮은 안압을 나타내었다. 또한 Kowa 비접촉성 안압계(TM-2000, Japan)와 Goldmann 압평안압계의 안압측정치의 상관계수는 0.8876(p=0.001)으로 높은 상관관계를 나타내었다. 결론적으로 저자들은 녹내장이 합병되어 있지 않은 백내장환자에서 백내장낭외적출술 및 인공수정체삽입술을 시행하여 술후 안압 변화를 관찰하여 유의한 안압감소 효과를 얻었으므로 고안압증이나 녹내장이 병발한 백내장 환자에서 백내장적출술 및 인공수정체삽입술 단독으로도 유용한 수술법이 될 수 있을 것으로 사료된다.

  • PDF

개의 Intraocular Lymphoma (Intraocular Lymphoma in a Dog)

  • 우흥명
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.429-433
    • /
    • 2001
  • 림프종은 임상에서 많이 발생되는 개의 악성 종양이지만, 눈 안에서의 발생은 그 예가 드물다. 본 연구는, 수정체낭의 혼탁, 초자체 출혈, 전신적인 임파선증 및 복부중앙의 응괴가 관찰되는 8년령 잡종견에서 병력, 임상증상, 방사선 검사, 세포 및 조직병리학 검사, 화학요법에 의한 반응을 통하여 속발성 안내 염증을 동반하는 전신적인 다발성 lymphoma를 확진하는 방법을 알아보았다. 개의 눈 안에서 관찰되는 속발성 lymphoma는 전신적인 lymphoma를 예견하는 중요한 임상소견이 될 수 있으므로 수의 임상에 응용이 가능하리라 판단된다.

  • PDF

버니 다초점인공수정체의 임상적 효용성 (Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery)

  • 조명호;박재영;박병건;이종수
    • 대한안과학회지
    • /
    • 제59권12호
    • /
    • pp.1129-1136
    • /
    • 2018
  • 목적: 백내장수술 후 다초점인공수정체인 BunnyLens $MF^{(R)}$를 삽입한 환자의 수술 전과 수술 후 근거리 및 원거리에서의 시력교정에 관한 임상적 유용성을 알아보고자 하였다. 대상과 방법: 백내장으로 진단을 받고 다초점인공수정체 삽입술을 시행한 환자 중에서 $ReSTOR^{(R)}$를 삽입한 39안을 대조군, BunnyLens $MF^{(R)}$를 삽입한 26안을 실험군으로 분류하여, 총 65안을 분석하였다. 수술 전과 수술 후 1주째, 8주째, 24주째의 원거리 및 근거리 시력과 난시, 구면렌즈대응치, 대비감도를 비교하고, 두 군 간의 수술 후 임상적 유용성을 비교하였다. 결과: 두 군 모두에서 술 전에 비해 술 후 원거리 및 근거리 시력, 구면렌즈대응치가 유의하게 향상되었으나(p<0.05), 두 군 간의 유의한 차이는 없었다(p>0.05). 수술 후 원거리 및 근거리 평균 시력과 난시, 대비감도는 대조군과 실험군은 두 군 간 유의한 차이가 없었다(p>0.05). 구면렌즈대응치의 평균실제오차는 $ReSTOR^{(R)}$와 BunnyLens $MF^{(R)}$는 수술 24주째, 각각 $-0.17{\pm}0.50D$, $-0.34{\pm}0.52D$였고 유의한 차이가 없었다(p>0.05). 결론: 백내장수술 후에 삽입되는 다초점인공수정체인 BunnyLens $MF^{(R)}$는 원거리 및 근거리 시력에서 $ReSTOR^{(R)}$와 유의한 차이가 없었고, 정시안을 기준으로 통계적으로 유의하지는 않으나, $ReSTOR^{(R)}$에 비해 BunnyLens $MF^{(R)}$가 근시의 경향을 보였다.

Rotational Stability of AcrySof Toric Intraocular Lens Over Time: Influence of Capsulorhexis Contraction

  • Kim, Joong Hee;Cho, Kyong Jin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2020
  • Background and Objectives To evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and Methods A prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. Results The mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). Conclusion The direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.