• Title/Summary/Keyword: intracranial stent

Search Result 46, Processing Time 0.025 seconds

Clinical Safety and Effectiveness of Stent-Assisted Coil Embolization with Neuroform Atlas Stent in Intracranial Aneurysm

  • Kim, Chang Hyeun;Kim, Young Ha;Sung, Soon Ki;Son, Dong Wuk;Song, Geun Sung;Lee, Sang Weon
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.80-88
    • /
    • 2020
  • Objective : Stent-assisted coil embolization (SAC) is commonly used for treating wide-neck intracranial aneurysms. In this study, we aimed to assess the clinical safety and efficacy of the NeuroForm Atlas Stent during SAC of intracranial aneurysms. Methods : We retrospectively analyzed data from patients with ruptured and unruptured cerebral aneurysms, who underwent SAC using the NeuroForm Atlas between February 2018 and July 2018. Favorable clinical outcomes and degree of aneurysm occlusion were defined as a modified Rankin scale score of ≤2 and a Raymond-Roy occlusion classification (RROC) class I/II during the immediate postoperative period and at the 6-month follow-up, respectively. Results : Thirty-one consecutive patients with 33 cases, including 11 ruptured and 22 unruptured cases were treated via NeuroForm Atlas SAC. Among the 22 unruptured cases with 24 unruptured aneurysms had favorable clinical outcome. Complete occlusion (RROC I) was achieved in 16 aneurysms (66.7%), while neck remnants (RROC II) were observed in six aneurysms (25%). Among the 11 patients with ruptured aneurysms, two died due to re-bleeding and diabetic ketoacidosis. In ruptured cases, RROC I was observed in eight (72.7%) and RROC II was observed in three cases (27.3%). At the 6-month follow-up, no clinical events were observed in the 22 unruptured cases. In the ruptured nine cases, five patients recovered without neurologic deficits, while four experienced unfavorable outcomes at 6 months. Of the 29 aneurysms examined via angiography at the 6-month follow-up, 19 (65.5%) were RROC I, eight (27.6%) were RROC II and two (6.9%) were RROC III. There were no procedure-related hemorrhagic complications. Conclusion : In this study, we found that stent-assisted coil embolization with NeuroForm Atlas stent may be safe and effective in the treatment of wide-neck intracranial aneurysms. NeuroForm Atlas SAC is feasible for the treatment of both ruptured and unruptured wide-neck aneurysms.

Silent Embolic Infarction after Neuroform Atlas Stent-Assisted Coiling of Unruptured Intracranial Aneurysms

  • Seungho Shin;Lee Hwangbo;Tae-Hong Lee;Jun Kyeung Ko
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.42-49
    • /
    • 2024
  • Objective : There is still controversy regarding whether neck remodeling stent affects the occurrence of silent embolic infarction (SEI) after aneurysm coiling. Thus, the aim of the present study is to investigate the incidence of SEI after stent-assisted coiling (SAC) using Neuroform Atlas Stent (NAS) and possible risk factors. This study also includes a comparison with simple coiling group during the same period to estimate the impact of NAS on the occurrence of SEI. Methods : This study included a total of 96 unruptured intracranial aneurysms in 96 patients treated with SAC using NAS. Correlations of demographic data, aneurysm characteristics, and angiographic parameters with properties of SEI were analyzed. The incidence and characteristics of SEI were investigated in 28 patients who underwent simple coiling during the same period, and the results were compared with the SAC group. Results : In the diffusion-weighted imaging obtained on the 1st day after SAC, a total of 106 SEI lesions were observed in 48 (50%) of 96 patients. Of these 48 patients, 38 (79.2%) had 1-3 lesions. Of 106 lesions, 74 (69.8%) had a diameter less than 3 mm. SEI occurred more frequently in older patients (≥60 years, p=0.013). The volume of SEI was found to be significantly increased in older age (≥60 years, p=0.032), hypertension (p=0.036), and aneurysm size ≥5 mm (p=0.047). The incidence and mean volume of SEI in the SAC group (n=96) were similar to those of the simple coiling group (n=28) during the same period. Conclusion : SEIs are common after NAS-assisted coiling. Their incidence in SAC was comparable to that in simple coiling. They occurred more frequently at an older age. Therefore, the use of NAS in the treatment of unruptured intracranial aneurysm does not seem to be associated with an increased risk of thromboembolic events if antiplatelet premedication has been performed well.

Amaurosis Fugax Associated with Stenosis of the Intracranial Internal Carotid Artery : Successful Restoration of Ophthalmic Artery Flow by Stent Placement

  • Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.28-30
    • /
    • 2006
  • Two patients presented with amaurosis fugax[AMF]. despite treatment with antiplatelet drugs and anticoagulants due to previous transient ischemic attacks. Angiography demonstrated severe stenosis in the cavernous and petrous internal carotid artery[ICA] respectively, with reduced flow in the ophthalmic artery[OA]. Endovascular stent placement in both patients resulted in normalization of the vessel lumen of the stenotic vessel segments. In addition, complete restoration of OA flow was noted immediately after stenting. Both patients showed no further episode of AMF over a follow-up period of 38 and 23 months respectively. Our clinical and angiographic findings suggest that hemodynamic Insufficiency in retinal vasculature caused by a stenosis of the cavernous or petrous ICA can be treated successfully by endovascular stent.

Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms

  • Kwon, Hyon-Jo;Lim, Jeong-Wook;Byoun, Hyoung Soo;Koh, Hyeon-Song
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.136-141
    • /
    • 2021
  • The crossing Y-stent method is one of the indispensable techniques to achieve sufficient neck coverage during coil embolization of bifurcation aneurysms with a wide neck and/or branch incorporation. However, the inevitable hourglass-like expansion of the second stent at the crossing point can result in insufficient vessel wall apposition, reduced aneurysm neck coverage, delayed endothelialization, and subsequent higher risks of acute or delayed thrombosis. It also interferes with engagement of the microcatheter into the aneurysm after stent installation. We expected to be able to reduce these disadvantages by installing a noncrossing type Y-stent using the Solitaire AB stent, which is fully retrievable with a tapered proximal end. Here we report the techniques and two successful cases.

Nationwide Mortality Data after Flow-Diverting Stent Implantation in Korea

  • Kim, Tackeun;Kwon, O-Ki;Lee, Heeyoung;Cho, Min Jai;Jeong, Hyun Jean;Ban, Seung Pil
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.219-223
    • /
    • 2018
  • Objective : To investigate nationwide statistics on flow-diverting stent usage for cerebral aneurysm treatment and related mortality data. Methods : We requested data extraction from the National Health Insurance Service claims database using electronic data interchange codes (J3207064, J3207073). Patient and hospital information as well as death statistics were collected from the database. Results : A total of 169 procedures were performed using flow-diverting stents for cerebral aneurysm treatment from November 2014 to December 2016 in Korea. The majority of primary diagnosis was unruptured intracranial aneurysm. During the study period, nine subjects died, including one patient initially diagnosed with subarachnoid hemorrhage. The crude mortality rate was 5.3%. Five patients died within one month after the procedure; therefore, the estimated periprocedural mortality rate was $3.0{\pm}1.3%$. The mortality rate as of the last day of 2016 was $6.3{\pm}2.1%$. Conclusion : In a 171 person-year follow-up in a Korean series, nine deaths occurred after flow-diverting stent treatment. The crude mortality rate in Korea (5.3%) was higher than that reported in a previous meta-analysis (3.8%).

Outcomes of Stent-Assisted Coiling Using the Neuroform Atlas Stent in Unruptured Wide-Necked Intracranial Aneurysms

  • Kwon, Ohyuk;Chung, Joonho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.23-29
    • /
    • 2021
  • Objective : Although stent-assisted coiling (SAC) has been reported to be safe and effective in treating wide-necked aneurysms, the technique has procedure-related complications. Thus, we reported our experiences of SAC using the Neuroform Atlas stent in treating wide-necked aneurysms and evaluated the incidence of and risk factors for procedure-related complications. Methods : From March 2018 to August 2019, we treated 130 unruptured wide-necked aneurysms in 123 patients with Neuroform Atlas stents. Angiographic results and clinical outcomes were reviewed retrospectively. Clinical and angiographic follow-up were performed in all cases (mean, 12.4 months) after the procedure. Results : There were eight cases (6.2%) of procedure-related complications (two dissections, five thromboembolisms, and one hemorrhage) and two (1.5%) of delayed complications (one ischemia and one hemorrhage). There was one case (0.8%) of failure of stent deployment and one (0.8%) of suboptimal positioning of the stent. Follow-up angiography showed complete obliteration in 103 (79.2%), residual neck in 16 (12.3%), and residual aneurysm in 11 cases (8.5%). Aneurysm locations in the middle cerebral artery (odds ratio [OR], 2.211; p=0.046) and the anterior communicating artery (OR, 2.850; p=0.039) were associated with procedure-related complications on univariate analysis. However, no independent risk factor for procedure-related complications was noted in multivariate analysis. Conclusion : The Neuroform Atlas showed a high rate of technical success. Good clinical and radiographic outcomes in early follow-up suggests that the device is feasible and safe. SAC of aneurysms on the middle cerebral artery or anterior communicating artery may require more attention to prevent possible procedure-related complications.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.

Temporary Semi-Jailing Technique for Coil Embolization of Wide-Neck Aneurysm with Small Caliber Parent Artery Following Incomplete Clipping

  • Byun, Jun Soo;Kim, Jae Kyun;Lee, Hwa Yeon;Hwang, Sung Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.241-244
    • /
    • 2013
  • The authors describe the use of a self-expandable stent in a temporary deployment for treatment of a very wide-neck A1 segment of anterior cerebral artery (ACA) aneurysm following incomplete clipping. A 39-year-old hypertensive man presenting with seizure-like movement underwent computed tomography, which showed acute subarachnoid hemorrhage and an A1 segment of ACA aneurysm with superior and inferior projection. He underwent surgical clipping of the aneurysm, but superior and posterior portion of wide-neck aneurysm remained. We decided to treat the remnant aneurysm using an endovascular modality. After selection of the aneurysm, coil packing was performed assisted by the temporary semi-jailing technique. The Enterprise stent (Cordis Neurovascular, Miami, FL, USA) was deployed and recaptured repeatedly for angiography to ensure safety of the small caliber parent artery. Successful semi-deployment and recapture of the stent allowed subtotal coil occlusion of the aneurysm with good anatomic and clinical results. No complications were encountered. The stent could be recaptured up to the point where the proximal end of the stent marker was aligned with distal marker band of the microcatheter, approximately 70% of the stent length. The temporary semi-jailing technique is feasible for wide-neck aneurysm with small caliber parent artery.

Various Techniques of Stent-Assisted Coil Embolization of Wide-Necked or Fusiform Middle Cerebral Artery Aneurysms : Initial and Mid-Term Results

  • Won, Yu Sam;Rho, Myung Ho;Kim, Byung Moon;Park, Hee Jin;Kwag, Hyon Ju;Chung, Eun Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.5
    • /
    • pp.274-280
    • /
    • 2013
  • Objective : To evaluate the feasibility and clinical and angiographic outcomes of stent-assisted embolization for complex middle cerebral artery (MCA) aneurysms. Methods : The records of 23 consecutive patients with 24 MCA aneurysms, who underwent stent-assisted embolization of the aneurysm, were retrospectively evaluated. Results : Fifteen aneurysms were treated with one stent and 8 were treated using more than two stents (5 a stent-within-a-stent, 1 triple stents, and two Y-stent). Angiographically, complete or near complete occlusion was achieved in 15 aneurysms (65.2%), residual neck in five (21.7%), and residual aneurysm in three (13.1%). Five aneurysms demonstrated thrombosis within the stent during the procedure and hospitalization, and were resolved by intraarterial and intravenous Tirofiban injection. Symptomatic thromboembolic complications were developed in five patients and permanent deficits demonstrated in two patients with modified Rankin Scale 1 and 2, respectively. Treatment-related permanent morbidity and mortality rates were 8.3% and 0% with relatively high complication rate. Angiographic follow-up was available in 17 aneurysms at 6-31 months (mean, 13.2 months) and showed stable or improved in 15 (88.2%) and major and minor recurrence in one, respectively. Conclusion : Complex MCA aneurysms could be treated by stent-assisted coiling and showed lower recanalization rate during mid-term follow-up by effective flow diversion due to various stent-assisted techniques. Our results warrant further study with a longer follow-up period in a larger sample.