• Title/Summary/Keyword: intra mode

Search Result 315, Processing Time 0.035 seconds

Theorizing the Transformation of Space Economy: Regulationist Perspectives on the Post-Socialist System Transformation (공간경제 전환의 이론화 : 체제전환에 대한 조절이론적 접근)

  • Kim, Boo-Heon;Lee, Sung-Cheol
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.24-44
    • /
    • 2008
  • Regulation theories has paid little attention to spatial regulation processes, while it has focused on economic and social regulation processes. More specifically, there have been little researches on regulationist approach to the transformation of the post-socialist system in the context of the space economy. Therefore, the article has attempted to conceptualize the transformation of space economy under the post-socialist system in the light of regulation theories. The space economy could be regarded as the foundation of the reproduction of social relations. Thus, the transformation of post-socialist system has led to the fundamental changes in enterprise and industrial networks as well as social relations in spatial contexts. In this perspective, the research has attempted to identify 'the mode of enterprise regulation' regarded as a codified firm networks by investigating intra-, inter- and extra-firm relations associated with the transformation of post-socialist system. Also, it has intended to suggest three types of the space economy - (1) disembedded economies based on the isolated networks and dissolution of pre-existing networks, (2) embedded economies based on the interaction of institutions and restructuring of networks, and (3) over-embedded economies based on the insulated institutions and endurance of pre-existing networks-in accordance with the governance, institution and networks in the post-socialist system.

  • PDF

Liquid Chromatography Quadrupole Time-Of-Flight Tandem Mass Spectrometry for Selective Determination of Usnic Acid and Application in Pharmacokinetic Study

  • Fang, Minfeng;Wang, Hui;Wu, Yang;Wang, Qilin;Zhao, Xinfeng;Zheng, Xiaohui;Wang, Shixiang;Zhao, Guifang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1684-1688
    • /
    • 2013
  • A rapid and sensitive method for determining usnic acid of Lethariella cladonioides in rat was established using high performance liquid chromatography (HPLC) quadrupole time-of-flight (QTOF) tandem mass (MS/MS). Rat plasma was pretreated by mixture of acetonitrile and chloroform to precipitate plasma proteins. Chromatographic separation was achieved on a column ($50{\times}2.1$ mm, $5{\mu}m$) with a mobile phase consisting of water (containing $5{\times}10^{-3}$ M ammonium formate, pH was adjusted to 3.0 with formic acid) and acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via collision induced dissociation (CID) under negative ionization mode. The MS/MS transitions monitored were m/z 343.0448 ${\rightarrow}$ m/z 313.2017 for usnic acid and m/z 153.1024 ${\rightarrow}$ m/z 136.2136 for protocatechuic acid (internal standard). The linear range was calculated to be 2.0-160.0 ng/mL with a detection limit of 3.0 pg/mL. The inter- and intra-day accuracy and precision were within ${\pm}7.0%$. Pharmacokinetic study showed that the apartment of usnic acid in vivo confirmed to be a two compartment open model. The method was fully valid and will probably be an alternative for pharmacokinetic study of usnic acid.

A Frequency Domain DV-to-MPEG-2 Transcoding (DV에서 MPEG-2로의 주파수 영역 변환 부호화)

  • Kim, Do-Nyeon;Yun, Beom-Sik;Choe, Yun-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Digital Video (DV) coding standards for digital video cassette recorder are based mainly on DCT and variable length coding. DV has low hardware complexity but high compressed bit rate of about 26 Mb/s. Thus, it is necessary to encode video with low complex video coding at the studios and then transcode compressed video into MPEG-2 for video-on-demand system. Because these coding methods exploit DCT, transcoding in the DCT domain can reduce computational complexity by excluding duplicated procedures. In transcoding DV into MPEC-2 intra coding, multiplying matrix by transformed data is used for 4:1:1-to-4:2:2 chroma format conversion and the conversion from 2-4-8 to 8-8 DCT mode, and therefore enables parallel processing. Variance of sub block for MPEG-2 rate control is computed completely in the DCT domain. These are verified through experiments. We estimate motion hierarchically using DCT coefficients for transcoding into MPEG-2 inter coding. First, we estimate motion of a macro block (MB) only with 4 DC values of 4 sub blocks and then estimate motion with 16-point MB using IDCT of 2$\times$2 low frequencies in each sub block, and finish estimation at a sub pixel as the fifth step. ME with overlapped search range shows better PSNR performance than ME without overlapping.

  • PDF

Ursodeoxycholic Acid Ameliorates Pain Severity and Cartilage Degeneration in Monosodium Iodoacetate-Induced Osteoarthritis in Rats

  • Moon, Su-Jin;Jeong, Jeong-Hee;Jhun, Joo Yeon;Yang, Eun Ji;Min, Jun-Ki;Choi, Jong Young;Cho, Mi-La
    • IMMUNE NETWORK
    • /
    • v.14 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • Osteoarthritis (OA) is a degenerative joint disease characterized by a progressive loss of cartilage. And, increased oxidative stress plays a relevant role in the pathogenesis of OA. Ursodeoxycholic acid (UDCA) is a used drug for liver diseases known for its free radical-scavenging property. The objectives of this study were to investigate the in vivo effects of UDCA on pain severity and cartilage degeneration using an experimental OA model and to explore its mode of actions. OA was induced in rats by intra-articular injection of monosodium iodoacetate (MIA) to the knee. Oral administration UDCA was initiated on the day of MIA injection. Limb nociception was assessed by measuring the paw withdrawal latency and threshold. Samples were analyzed macroscopically and histologically. Immunohistochemistry was used to investigate the expression of interleukin-$1{\beta}$ (IL-$1{\beta}$), IL-6, nitrotyrosine and inducible nitric oxide synthase (iNOS) in knee joints. UDCA showed an antinociceptive property and attenuated cartilage degeneration. OA rats given oral UDCA significantly exhibited a decreased number of osteoclasts in subchondral bone legion compared with the vehicle-treated OA group. UDCA reduced the expression of IL-$1{\beta}$, IL-6, nitrotyrosine and iNOS in articular cartilage. UDCA treatment significantly attenuated the mRNA expression of matrix metalloproteinase-3 (MMP-3), -13, and ADAMTS5 in IL-$1{\beta}$-stimulated human OA chondrocytes. These results show the inhibitory effects of UDCA on pain production and cartilage degeneration in experimentally induced OA. The chondroprotective properties of UDCA were achieved by suppressing oxidative damage and inhibiting catabolic factors that are implicated in the pathogenesis of cartilage damage in OA.

Validation of a HPLC MS/MS Method for Determination of Doxorubicin in Mouse Serum and its Small Tissues (마우스 혈장과 조직에서의 doxorubicin 측정 HPLC-MS/MS 방법)

  • Park, Jung-Sun;Kim, Hye-Kyung;Lee, Hye-Won;Lee, Mi-Hyun;Kim, Hyun-Gi;Chae, Soo-Wan;Chae, Han-Jung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • Doxorubicin (DXR) is a type of anti-cancer drug called an 'anthracycline glycoside', It works by impairing DNA synthesis, a crucial feature of cell division, and thus is able to target rapidly dividing cells. Doxorubicin is a very serious anti-cancer medication with definite potential to do great harm as well as great good. A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method was developed to identify and quantify DXR in small-volume biological samples. After the addition of internal standard (IS, $5{\mu}L\;of\;1{\mu}M/ml$ daunorubicin methanol solution) into the serum sample, the drug and IS were extracted by methanol. Following vortex for a 1min and centrifugation at 15,000g for 10 min the organic phase was transferred and evaporated under a vacuum. The residue was reconstituted with $350{\mu}L$ of mobile phase and $10{\mu}L$ was injected into C18 column with mobile phase composed of 0.05M ammonium acetate (0.1 M acetic acid adjusted to pH 3.5) and acetonitrile (40:60, v/v). The flow rate was kept constant at $350{\mu}L/min$. The ions were quantified in the multiple reaction mode (MRM), using positive ions, on a triple quadrupole mass spectrometer. The lower limits of quantification for Doxorubicin in plasma and small tissues were approximately 0.5 ng/mL and 0.5 ng/mL respectively. Intra- and inter-assay accuracy (% of nominal concentration) and precision (% CV) for all analytes were within 15%, respectively.

  • PDF

Design of video encoder using Multi-dimensional DCT (다차원 DCT를 이용한 비디오 부호화기 설계)

  • Jeon, S.Y.;Choi, W.J.;Oh, S.J.;Jeong, S.Y.;Choi, J.S.;Moon, K.A.;Hong, J.W.;Ahn, C.B.
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.732-743
    • /
    • 2008
  • In H.264/AVC, 4$\times$4 block transform is used for intra and inter prediction instead of 8$\times$8 block transform. Using small block size coding, H.264/AVC obtains high temporal prediction efficiency, however, it has limitation in utilizing spatial redundancy. Motivated on these points, we propose a multi-dimensional transform which achieves both the accuracy of temporal prediction as well as effective use of spatial redundancy. From preliminary experiments, the proposed multi-dimensional transform achieves higher energy compaction than 2-D DCT used in H.264. We designed an integer-based transform and quantization coder for multi-dimensional coder. Moreover, several additional methods for multi-dimensional coder are proposed, which are cube forming, scan order, mode decision and updating parameters. The Context-based Adaptive Variable-Length Coding (CAVLC) used in H.264 was employed for the entropy coder. Simulation results show that the performance of the multi-dimensional codec appears similar to that of H.264 in lower bit rates although the rate-distortion curves of the multi-dimensional DCT measured by entropy and the number of non-zero coefficients show remarkably higher performance than those of H.264/AVC. This implies that more efficient entropy coder optimized to the statistics of multi-dimensional DCT coefficients and rate-distortion operation are needed to take full advantage of the multi-dimensional DCT. There remains many issues and future works about multi-dimensional coder to improve coding efficiency over H.264/AVC.

Quantification of Entacapone in Human Plasma by HPLC Coupled to ESI-MS/MS Detection: Application to Bioequavalence Study (체외에서 ESI-MS/MS 탐지에 연결된 HPLC에 의한 Entacapon의 수량화: 생물학적 동등성 연구에 적용)

  • Balasekhara Reddy., Ch.;Baburao., Ch.;Chandrasekhar., K.B.;Kanchanamala., K.;RihanaParveen., S.K.;Ravikumar., Konda
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.523-532
    • /
    • 2010
  • The proposed method is simple, sensitive and specific Liquid chromatography-tandem mass spectrometry (LCESI-MS/MS) method for the quantification of Entacapone (EA) in human plasma using Entacapone-d10 (EAD10) as an internal standard (IS). Chromatographic separation was performed on Zorbax SB-C18, $2.1{\times}50\;mm$, $5\;{\mu}m$ column, mobile phase composed of 10 mM Ammonium formate (pH 3.0): Acetonitrile (60:40 v/v), with a flow-rate of 0.7 mL/min, followed by Liquid-liquid extraction. EA and EAD10 were detected with proton adducts at m/z $306.1{\rightarrow}233.1$ and $316.3{\rightarrow}233.0$ in multiple reaction monitoring (MRM) positive mode respectively. The method was validated over a linear concentration range of 1.00 - 2000.00 ng/mL with correlation coefficient ($r^2$) $\geq$ 0.9993. Intra and inter-day Precision within 3.60 to 7.30 and 4.20 to 5.50% and Accuracy within 97.30 to 104.20 and 98.30 to 105.80% proved for EA. This method is successfully applied in the bioequivalence study of healthy Indian human volunteers.

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.