• Title/Summary/Keyword: interventional

Search Result 580, Processing Time 0.025 seconds

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

Management of Elderly Patients with Spinal Disease: Interventional Nonsurgical Treatment (고령 척추 질환자의 치료: 중재적 비수술 치료)

  • Park, Soo-An
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Owing to the upward shift in age structure, there is an increasing number of spinal diseases specific to elderly patients. Elderly spinal patients typically have a poor general condition with several medical comorbidities, low bone mineral density, more extensive and severe degeneration, and less effective treatment outcomes than young patients. This is why spinal physicians need to establish interventional nonsurgical treatment modalities for elderly patients with spinal disease. The objective of this study was to define the spinal disorders problematic to elderly patients and discuss the nonsurgical treatments for each subject.

A Study on the Space Composition of Hybrid Operating Unit in General Hospital (1) (종합병원 하이브리드수술유니트의 공간구성에 관한 연구 (1))

  • Kim, Byeong Soo;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.2
    • /
    • pp.23-34
    • /
    • 2024
  • Purpose: The Hybrid care environment, combining interventional procedures and surgeries in one space, is crucial for managing complex diseases, responding to emergencies, and reducing recovery times and pain. This study provides foundational data for creating architectural guidelines for a Hybrid Operating Unit in a general hospital's surgical department, focusing on cardiovascular care. Methods: The study analyzed the spatial and configuration types of the Vascular Angiography Unit and the Cardiac Operating Unit, which are the basic components of the Hybrid Operating Unit, through a literature review. Based on the initial research findings, interviews with experts were conducted. Results: In the Hybrid Operating Process, the study proposed spatial configuration alternatives that consider the positioning of medical staff and the types and arrangement changes of equipment, including Angiography, Heart-lung machines, and other surgical tools and instruments. Implications: The integration of the two units leads to increased diversity and demand for medical staff, equipment, and supplies during surgical and interventional procedures. Therefore, strategic spatial configurations and equipment placement are necessary to effectively respond to these needs.

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

The Effect of Lumbosacral Stabilization Exercise on Oswestry Disability Index and Gait Velocity of Patients with Chronic Low Back Pain (허리엉치 안정화운동이 만성허리통증환자의 허리통증장애지수와 보행속도에 미치는 영향)

  • Kang, Jeong-Il;Jeong, Dae-Keun
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.243-250
    • /
    • 2013
  • The present study is to determine the effect of lumbosacral stabilization exercise program on back pain disorder and gait velocity of patients with chronic low back pain. The subject was extracted randomly from 34 patients with chronic low back pain and divided into 18 patients of experimental group and 16 patients of control group. Before the experiment, the Oswestry disability index examination and analysis of gait speed were performed. Then, a conventional interventional therapy of physiotherapy was performed with the experimental group along with the lumbosacral stabilization exercise while only the conventional interventional therapy was done to the control group. Both groups did the above treatment every 30 minutes, four times a week for four weeks. Then, post-examination was carried out followed by comparing the back pain disorder index and gait velocity before and after the experiment for the two groups. The back pain disorder index showed that both experimental and control groups had significant difference within the group (p>.01)(p>.05), With regard to the gait velocity, both experimental and control groups had a significant difference within the experimental group and between the groups (p>.001)(p>.05).

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.

Clinical Efficacy and Prognosis Factors for Advanced Hepatoblastoma in Children: A 6-year Retrospective Study

  • Zhang, Yi;Zhang, Wei-Ling;Huang, Dong-Sheng;Hong, Liang;Wang, Yi-Zhuo;Zhu, Xia;Hu, Hui-Min;Zhang, Pin-Wei;Yi, You;Han, Tao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4583-4589
    • /
    • 2013
  • Objective: This study aimed to investigate the effect of multimodality treatment of advanced paediatric hepatoblastoma (HB) and the factors affecting prognosis. Methods: A total of 35 children underwent multimodality treatments consisting of chemotherapy, surgery, interventional therapy, and autologous peripheral blood stem cell transplantation. The patients were followed up every month. Results: Serum AFP levels in 33 out of 35 patients in this study were significantly increased (P = 0.0002). According to the statistical scatter plot, the values of serum AFP on the 25th, 50th, and 75th percentages were 1,210, 1,210 and 28,318 ng/dl, respectively. Of the 35 cases, 21 were stage IV. 18 cases were treated with systemic chemotherapy before surgery, and 3 cases with locally interventional chemotherapy before surgery. Statistical analysis showed that the preferred interventional treatment affected prognosis, and that there was a statistically significant difference (P = 0.024). Some 33 patients completed the follow-up, of which 17 were in complete remission (CR), 5 were in partial remission (PR), 1 became disease progressive (DP), and 10 died. The remission and overall survival rates were 66.7% (22/33) and 69.7% (23/33), respectively. Patients with the mixed HB phenotypes had worse prognoses than the epithelial phenotype (P < 0.001), and patients in stage IV had a lower survival rate than those in stage III (P < 0.001). Conclusion: Multimodality treatment can effectively improve remission rate and prolong the survival of children with advanced HB. In addition, alpha-fetoprotein (AFP), a tumor marker of liver malignant tumors, HB pathological classification, and staging are highly useful in predicting prognosis.

Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention (뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구)

  • Kim, Jongdeok;Ahn, ByeoungJu;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The bi-plane cerebrovascular angiography radiation is done the radiation exposure at the forward and lateral direction as opposed to the one of the source. So, the exposure dose of radiation workers increases further. Therefore, the medical diagnostic radiation workers as well as patients is interested to ways to reduce the dose. The exposure dose of cerebral angiography and interventional radiology must be considered the primary radiation of X-ray tube directly, scattered primary radiation between lateral tube and lateral detector and relatively small secondary scatter radiation in the walls of room. The aim of study is that the exposure dose of primary and scatter radiation reduce as much as possible to install protection device of lateral protection than common shielding of table and ceiling. As a result, the dose of fluoroscopy was reduced approximately 3.64 times the gonads, thyroid approximately 3.13 times, 4.42 times around eyes. And the dose of DSA was reduced approximately 4.98 times the gonads, thyroid approximately 3.00 times, 1.67 times around eyes. Consequently, medical practitioners can be helpful for radiation dose-exposure for the lateral protection of bi-plane cerebrovascular angiography more than the common shield method in cerebrovascular angiography and interventional radiological procedures.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.