• Title/Summary/Keyword: interval time

Search Result 3,707, Processing Time 0.046 seconds

Sinus Node Function after Extended Transseptal Approach for Mitral Valve Surgery: 164 Clinical Cases (경중격 절개방식을 좌심방 상부까지 연장시킨 방법을 통한 승모판막 수술 후 동방 결절 기능부전에 대한 164예 임상분석)

  • Ryu Se Min;Kim Hyun Koo;Cho Yang Hyun;Sim Jae Hoon;Sohn Young-sang;Choi Young Ho;Kim Hark Jei
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.214-220
    • /
    • 2005
  • Extended transseptal approach can provide an excellent view of the mitral valve but the safety of this approach is controversial because this incision requires transaction of the sinus node artery, which in most cases and can result postoperative arrhythmia. The purpose of this study was to evaluate perioperative and longterm conduction disturbances and the cardiac rhythms of patients who underwent an extended transseptal approach for mitral valve surgery. Material and Method: Postoperative cardiac rhythms were analyzed in the 164 consecutive patients who received mitral valve replacements with a extended transseptal approach between March 1992 and July 2003. Result: Of the 84 patients in normal sinus rhythm, 34 ($39\%$) had developed transient junctional rhythm and atrial fibrillation after operation, lasting less than 72 hours in most of cases. No intractable arrhythmias occurred. Most of these arrhythmia were not detected at the time of discharge and only 8 patients ($9\%$) had atrial fibrillation at discharge. Postoperative PR intervals increased for 1 week, then decreased within 2 weeks postoperatively, and returned to normal range by 6 months postoperatively. During the postoperative period, 4 of the 78 patients with preoperative atrial fibrillation developed normal sinus thythm. Conclusion: The post-operative arrhythmias were temporary and showed no significant complications after extended transseptal approach for the mitral valve surgery.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Mushroom growth and cultivation environment at cultivation house of vinyl bag cultivation Shiitake mushroom on high-temperature period (고온기 표고 톱밥재배용 재배사 내의 환경 제어시스템과 버섯생육 온도)

  • Jhune, Chang-Sung;Kong, Won Sik;Park, Hye-Sung;Cho, Jae-Han;Lee, Kang-Hyo
    • Journal of Mushroom
    • /
    • v.12 no.4
    • /
    • pp.263-269
    • /
    • 2014
  • Although sawdust cultivation of shiitake (Lentinula edodes) is becoming more common, it is insufficiently competitive in spring and autumn, the best time to breed shiitake. Thus, it is urgently needed to develop a technique for all year round cultivation of shiitake using mushroom growing beds. In the present study, the temperature changes according to the location of shiitake cultivation facilities were investigated. We confirmed that a refrigerator, an air conditioner, triple membranes, shiitake cultivation beds, fog nozzles which were installed in the shiitake cultivation facilities play an important role in keeping the low temperature. Bag cultivation of shiitake was tested in temperature variation from $14^{\circ}C$ to $29^{\circ}C$ with a $3^{\circ}C$ interval to know its cultivating temperature range in hot summer season. In summary, the sawdust cultivation of shiitake is possible when the temperature difference between top and bottom is maintained below $1^{\circ}C$. And the temperature of the shiitake cultivation facilities should be maintained below $23^{\circ}C$ in the induction period for fruitbody formation.

Evaluation of Soil and Fertilizer Management Techniques Applied by Farmers in Forcing and Semi-forcing Cucumber Cultivation Facilities (오이 촉성재배와 반촉성재배 농가들의 토양 및 시비관리기술 평가)

  • Lee, Ju-Young;Jang, Byoung-Choon;Sung, Jwa-Kyung;Lee, Su-Yeon;Kim, Rog-Young;Lee, Ye-Jin;Park, Yang-Ho;Kang, Sung-Soo;Hyun, Byung-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.983-991
    • /
    • 2012
  • These days, agricultural products cultivated in facilities occupy the highest percentage of agricultural output price. Specifically cucumbers have been one of the crops that farmers prefer to growing, because their prices were high. However, cucumber crop is sensitive to the soil and environments and it requires the exact crop management. In order to establish cultivation techniques for cucumbers, the current situation of cucumber cultivation was surveyed from ten cucumber farmlands; five farmlands of cucumber cultivation in forcing and five of semi-forcing practicing systems, respectably. The soil conditions were alluvial or valley in soil topology, moderately or poorly drainage in soil drainage classes, coarse loamy in soil texture family. Soil was managed with deep plowing combined with application of basal fertilizers such as compost, rice straw, oil cake, wood chip and chemical fertilizer. The whole soil was prepared in uniformly with rotary. Three major nutrients ($N-P_2O_5-K_2O$)of basal application were 815-464-529 kg $ha^{-1}$ in forcing and 197-135-151 kg $ha^{-1}$ in semi-forcing cultivation. Top dressing of fertilizer was supplied in fertigation system of macro and micro elements in 2~3 day interval with water irrigation. The average yields of cucumbers were $168t\;ha^{-1}$ with 381,000 thousand won $ha^{-1}$ in average gross profit (AGP) in forcing cultivation and $115t\;ha^{-1}$ with 177,000 thousand won $ha^{-1}$ in AGP in semi-forcing cultivation. Cucumber production during the winter season was considered to increase the gross profit because cucumber price tends to stay in high level during this time. The accumulation of soil chemicals like EC, available $P_2O_5$ and exchangeable cations could be controlled by rice straw application. The rice straw application increased soil temperature during the winter season, in exchange of soil air, and in extension of plant roots. In addition, the rice straw application somewhat affected decrease of salts accumulation.

Analysis of Sap Production and Composition of Acer okamotoanum from Artificial Stands in Different Tapping Time in Jin-ju Region in Korea (진주지역 인공식재 우산고로쇠의 수액 채취 시기별 출수량 및 성분 분석)

  • HUH, Jin-Sung;KIM, Jeong-Woon;YOON, Jun-Hyuck;LEE, Su-Yeon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.206-216
    • /
    • 2020
  • This study was conducted to analyze the sap flow and composition by tapping date in Acer akamotoanum from an artificial forest in the City of Jinju. The sap was collected from five saplings (diameter at breast height10-20 cm) in two phases with an interval of a month. During phase 1 (January 10, 2019 - February 9, 2019) with daily mean temperature of 1.16±2.15℃, 60.59 liters of sap was collected over 32 days. Phase 2 (February 12, 2019 - February 22, 2019) with daily mean temperature of 2.55±1.30℃ yielded 13.38 liters of sap over 11 days, which was a reduction to 22% of the total sap flow in phase 1. The analysis of sugar composition in the collected sap from phase 1 and 2 showed that sucrose concentration was 2.5% at its highest during the earlier days of collection and decreased to 0.8% at the end. Glucose and fructose concentrations were measured near 0, and were lower than sucrose concentration. The most prominent inorganic elements in the collected sap were potassium (41.69 - 89.75 mg/kg), calcium (24.66 - 48.14 mg/kg) and magnesium (10.18 - 27.25 mg/kg). The contents of sucrose and inorganic components between the samples collected from phase 1 and 2 did not show significant differences. The sap flow amounts of A. okamotoanum from different tapping periods showed a notable variation, but there were no significant differences in the contents of sugar or inorganic elements.

The Surgical Treatment of Atrial Fibrillation in Patients Undergoing Simultaneous Open Heart Surgery (심장세동의 수술요법)

  • Kim, Gi-Bong;Lee, Chang-Ha;Son, Dae-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.287-292
    • /
    • 1997
  • .Itrial fibrillation is one of the most common cardiac arrhythmias requiring treatment. About 60% of patients with mitral valvular disease have atrial fibrillation and one third of patients with atrial fibrillation may have the past history of thromboembolic events. Between April 1994 and June 1995, 20 patients with organic heart diseases combined with atrial fibrillation underwent open heart surgery including Cox-maze 111 procedure. There were 6 men and 14 women with an average age of 48 years (range, 31 to 66 years). Nineteen patients had valvular heart diseases and 1 ventricular septal defEct (VSD). Mean duration of atrial fibrillation was 36 months (:42 months) (range, 1 to 132 months). T e past medical history of thromboembolic events was positive in 7 patients (35%) and left atrial thrombus was detected in 9 patients (45%). The concomitant procedures were mitral valve replacement (MVR) and aortic valve replacement (AVR) in 5 patients, MVR in 4, MVd and tricuspid annuloplasty(TAP) in 4, mitral valvuloplasty(Mln) in 3, Mln and Tln in 1, MIW and coronary artery bypass surgery in 1, AVR in 1, and patch closure of VSD in 1. Mean aortic cross-clamping time was 175 minutes (range, 116 to 270 minutes). Atrial fibrillation recurred in 16 patients (80%) during the early postoperative period, but, recurrent atrial fibrillation was converted to regular rhythm at postoperative forty-first day in average. There was no early or late death in this series of 20 patients and postoperative complications were inappropriate tachycardia in 5 patients (25%), low cardiac output syndrome in 3 (15%), aggravated hemiplegic in 1, and acute renal failure in 1. Mean follow-up interval of patient was 16.5 months (range, 10.5 to 24 months) and all patients are currently in regular rhythm. Seventeen patients (85%) are in sinus rhythm and 3 (15%) in junctional rhythm. Right atrial contraction was detected in 95% of patients and left atrial contraction in 63% on postoperative transthoracic echocardiogram. The surgical treatment of atrial fibrillation concomitant with open heart surgery is warranted in the recent clinical setting of improved myocardial protection technique, considering the untoward side-effects of atrial fibrillation.

  • PDF

Using Spatial Data and Crop Growth Modeling to Predict Performance of South Korean Rice Varieties Grown in Western Coastal Plains in North Korea (공간정보와 생육모의에 의한 남한 벼 품종의 북한 서부지대 적응성 예측)

  • 김영호;김희동;한상욱;최재연;구자민;정유란;김재영;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.4
    • /
    • pp.224-236
    • /
    • 2002
  • A long-term growth simulation was performed at 496 land units in the western coastal plains (WCP) of North Korea to test the potential adaptability of each land unit for growing South Korean rice cultivars. The land units for rice cultivation (CZU), each of them represented by a geographically referenced 5 by 5 km grid tell, were identified by analyzing satellite remote sensing data. Surfaces of monthly climatic normals for daily maximum and minimum temperature, precipitation number of rain days and solar radiation were generated at a 1 by 1 km interval by spatial statistical methods using observed data at 51 synoptic weather stations in North and South Korea during 1981-2000. Grid cells felling within a same CZU and, at the same time, corresponding to the satellite data- identified rice growing pixels were extracted and aggregated to make a spatially explicit climatic normals relevant to the rice growing area of the CZU. Daily weather dataset for 30 years was randomly generated from the monthly climatic normals of each CZU. Growth and development parameters of CERES-rice model suitable for 11 major South Korean cultivars were derived from long-term field observations. Eight treatments comprised of 2 transplanting dates $\times$ 2 cropping systems $\times$ 2 irrigation methods were assigned to each cultivar. Each treatment was simulated with the randomly generated 30 years' daily weather data (from planting to physiological maturity) for 496 land units in WCP to simulate the growth and yield responses to the interannual climate variation. The same model was run with the input data from the 3 major crop experiment stations in South Korea to obtain a 30 year normal performance of each cultivar, which was used as a "reference" for comparison. Results were analyzed with respect to spatial and temporal variation in yield and maturity, and used to evaluate the suitability of each land unit for growing a specific South Korean cultivar. The results may be utilized as decision aids for agrotechnology transfer to North Korea, for example, germplasm evaluation, resource allocation and crop calendar preparation.

The Analysis and Treatment of Rotator Cuff Tear After Shoulder Dislocation in Middle-Aged and Elderly Patients (중·장년층에서 견관절 탈구 후에 발생한 회전근 개 파열에 대한 분석과 치료)

  • Ji, Jong-Hun;Park, Sang-Eun;Kim, Young-Yul;Shin, Eun-Su;Park, Bo-Youn;Jeong, Jae-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.20-26
    • /
    • 2010
  • Purpose: To evaluate clinical features and surgical results for rotator cuff tear secondary to shoulder dislocation in middle-aged and elderly patients. Materials and Methods: We reviewed 19 patients over 50 years of age who had rotator cuff tears combined with shoulder dislocation between October 2004 and October 2008. There were 7 males and 12 females with a mean age 64.7 years (range, 50 to 78 years). The average follow-up duration was 22 months (range, 8 to 56 months). We investigated the number of dislocations, the size of the cuff tear, the presence of Bankart lesions and the time interval from dislocation to surgery. We also investigated the ASES score, UCLA score, SST score, and shoulder range of motion before and after surgery. We analyzed clinical outcomes and contributing factors. Results: ASES scores improved from 30.2 preoperatively to 72.3 postoperatively; UCLA scores improved from 12.9 to 26.5; SST scores improved from 2.4 to 7.3. Range of motion improved significantly: forward flexion, abduction, external rotation and internal rotation were, respectively, $110.8({\pm}39.3)^{\circ}$, $107.7({\pm}40)^{\circ}$, $22.5({\pm}17.6)^{\circ}$ and L5 level preoperatively; postoperatively they were $153.6({\pm}20.6)^{\circ}$, $152.1({\pm}20.8)^{\circ}$, $36.4({\pm}22.7)^{\circ}$ and L1 level. Age, the presence of Bankart lesions and the number of dislocations were not correlated with clinical outcomes. But the size of the cuff tear was correlated with clinical results. Also, the duration from dislocation to surgery was correlated with postoperative UCLA and SST scores (p=0.039, p=0.038). Conclusion: For shoulder dislocation, it is important to achieve early diagnoses of rotator cuff tears in middle-aged and elderly patients. If these injuries are both present, early rotator cuff repair should be performed for better clinical results.

A Study on Perception and Attitudes of Examinees of Health Screening Center towards Health Examination (종합건강진단 수진자들의 건강진단에 대한 인식 및 태도에 관한 연구)

  • Bae, Seong-Wook;Lee, Kyeong-Soo;Kang, Pock-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.59-77
    • /
    • 1996
  • A survey was conducted to study perception and attitudes of examinees of health screening center towards items, cost and procedures of health examination and degree of satisfaction with health examination, from March 2 to May 31, 1995. The study population was 468 examinees received health examination at Health Screening & Diagnosis Center of Yeungnam University Hospital. A questionnaire method was used to collect data. The followings are summaries of findings : Examinees were predominantly male(77.4%); had college education(68.6%), and held white-collar workers(57.8%). Statistical significance of association between frequency of periodic health examination and other variables were tested by chi-square test. Examinees who have higher degree of concern regarding health and those who practice more exercise for health maintenance received health examination more frequently. The majority expressed that health examination is very beneficial and effective in terms of prevention and early detection of diseases. Also the majority revealed that they are satisfied with health examination. The majority expressed that procedures and time spent for health examination are adequate; interval of health examination is one year; and additional examination items are cerebral examination, neurological examination and gastrofibercope. The majority revealed that they want more information about chronic degenerative diseases and health maintenance and promotion. In conclusion, the study revealed that examinees seemed to have more positive perceptions and attitudes towards health examination.

  • PDF

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.