• Title/Summary/Keyword: interval number

Search Result 1,460, Processing Time 0.026 seconds

Free Vibration Analysis of Axisymmetric Conical Shell

  • Choi, Myung-Soo;Yeo, Dong-Jun;Kondou, Takahiro
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.5-16
    • /
    • 2016
  • Generally, methods using transfer techniques, like the transfer matrix method and the transfer stiffness coefficient method, find natural frequencies using the sign change of frequency determinants in searching frequency region. However, these methods may omit some natural frequencies when the initial frequency interval is large. The Sylvester-transfer stiffness coefficient method ("S-TSCM") can always obtain all natural frequencies in the searching frequency region even though the initial frequency interval is large. Because the S-TSCM obtain natural frequencies using the number of natural frequencies existing under a searching frequency. In this paper, the algorithm for the free vibration analysis of axisymmetric conical shells was formulated with S-TSCM. The effectiveness of S-TSCM was verified by comparing numerical results of S-TSCM with those of other methods when analyzing free vibration in two computational models: a truncated conical shell and a complete (not truncated) conical shell.

Coupled Heat and Mass Transfer in Absorption of Water Vapor into LiBr-$H_2O$ Solution Flowing over a Finned Inclined Surface (좁은 휜이 달린 경사면을 흐르는 리튬브로마이드 수용액 흡수기에서의 열 및 물질전달)

  • 조은준;서태범
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.860-867
    • /
    • 2001
  • Absorption of water vapor into LiBr-$H_2O$ O solution flowing over a finned inclined surface is numerically investigated. The momentum, energy, and diffusion equation are numerically solved using a finite difference method. The four different shapes of the wall surfaces are considered to find the best surface for absorption assuming that the wall temperature and the surface tension are constant. The effects of the fin interval and Reynolds number are investigated. Based on the numerical results, it is known that the parabolic surface shows better absorption performance than the other surfaces, and that water vapor absorption increases gradually with decreasing the fin interval.

  • PDF

Checkpoint Placement for Multiple Real-time Periodic Tasks with Hard Deadlines (하드 데드라인을 가지는 다중 실시간 주기적 태스크에서의 체크포인팅 기법)

  • Kwak, Seong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.8
    • /
    • pp.594-601
    • /
    • 2004
  • We analyze checkpoint strategy for multiple real-time periodic tasks with hard deadlines. Real-time tasks usually have deadlines associated with them. For multiple real-time tasks, checkpoint strategy considering deadlines of all tasks is very difficult to derive. We analyze the problem of checkpoint placement for such multiple periodic tasks. In our strategy, the interval between checkpoints is determined for each task considering its deadline. An approximated failure probability over a specified interval is derived. Then the number of checkpoints for each task is selected to minimize the approximated failure probability. To show the usefulness of our strategy, error bound between the exact and the approximated failure probability is estimated, which is revealed to be quite small.

Fast Volume Visualization Techniques for Ultrasound Data

  • Kwon Koo-Joo;Shin Byeong-Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.6-13
    • /
    • 2006
  • Ultrasound visualization is a typical diagnosis method to examine organs, soft tissues and fetus data. It is difficult to visualize ultrasound data because the quality of the data might be degraded by artifact and speckle noise, and gathered with non-linear sampling. Rendering speed is too slow since we can not use additional data structures or procedures in rendering stage. In this paper, we use several visualization methods for fast rendering of ultrasound data. First method, denoted as adaptive ray sampling, is to reduce the number of samples by adjusting sampling interval in empty space. Secondly, we use early ray termination scheme with sufficiently wide sampling interval and low threshold value of opacity during color compositing. Lastly, we use bilinear interpolation instead of trilinear interpolation for sampling in transparent region. We conclude that our method reduces the rendering time without loss of image quality in comparison to the conventional methods.

Use of uncertain numbers for appraising tensile strength of concrete

  • Tutmez, Bulent;Cengiz, A. Kemal;Sarici, Didem Eren
    • Structural Engineering and Mechanics
    • /
    • v.46 no.4
    • /
    • pp.447-458
    • /
    • 2013
  • Splitting tensile strength (STS) is a respectable mechanical property reflecting ability of the concrete. The STS of concrete is mainly related to compressive strength (CS), water/binder (W/B) ratio and concrete age. In this study, the assessment of STS is made by a novel uncertainty-oriented method which uses least square optimization and then predicts STS of concrete by uncertain (fuzzy) numbers. The approximation method addresses a novel integration of fuzzy set theory and multivariate statistics. The numerical examples showed that the method is applicable with relatively limited data. In addition, the prediction of uncertainty at various levels of possibility can be described. In conclusion, the uncertainty-oriented interval analysis can be suggested an effective tool for appraising the uncertainties in concrete technology.

Comparison of EWMA and CUSUM Charts with Variable Sampling Intervals for Monitoring Variance-Covariance Matrix

  • Chang, Duk-Joon
    • Journal of Integrative Natural Science
    • /
    • v.13 no.4
    • /
    • pp.152-157
    • /
    • 2020
  • To monitor all elements simultaneously of variance-covariance matrix Σ of several correlated quality characteristics under multivariate normal process Np($\underline{\mu}$, Σ), multivariate exponentially weighted moving average (EWMA) chart and cumulative sum (CUSUM) chart are considered and compared. Numerical performances of the considered variable sampling interval (VSI) charts are evaluated using average run length (ARL), average time to signal (ATS), average number of switches (ANSW) to signal, and the probability of switch Pr(switch) between two sampling interval d1 and d2 where d1 < d2. For small or moderate changes of Σ, the performances of multivariate EWMA chart is approximately equivalent to that of multivariate CUSUM chart.

Evaluation Method of College English Education Effect Based on Improved Decision Tree Algorithm

  • Dou, Fang
    • Journal of Information Processing Systems
    • /
    • v.18 no.4
    • /
    • pp.500-509
    • /
    • 2022
  • With the rapid development of educational informatization, teaching methods become diversified characteristics, but a large number of information data restrict the evaluation on teaching subject and object in terms of the effect of English education. Therefore, this study adopts the concept of incremental learning and eigenvalue interval algorithm to improve the weighted decision tree, and builds an English education effect evaluation model based on association rules. According to the results, the average accuracy of information classification of the improved decision tree algorithm is 96.18%, the classification error rate can be as low as 0.02%, and the anti-fitting performance is good. The classification error rate between the improved decision tree algorithm and the original decision tree does not exceed 1%. The proposed educational evaluation method can effectively provide early warning of academic situation analysis, and improve the teachers' professional skills in an accelerated manner and perfect the education system.

The effect of the number of subintervals upon the quantification of the seismic probabilistic safety assessment of a nuclear power plant

  • Ji Suk Kim;Man Cheol Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1420-1427
    • /
    • 2023
  • Seismic risk has received increased attention since the 2011 Fukushima accident in Japan. The seismic risk of a nuclear power plant is evaluated via seismic probabilistic safety assessment (PSA), for which several methods are available. Recently, the discrete approach has become widely used. This approximates the seismic risk by discretizing the ground motion level interval into a small number of subintervals with the expectation of providing a conservative result. The present study examines the effect of the number of subintervals upon the results of seismic risk quantification. It is demonstrated that a small number of subintervals may lead to either an underestimation or overestimation of the seismic risk depending on the ground motion level. The present paper also provides a method for finding the boundaries between overestimation and underestimation regions, and illustrates the effect of the number of subintervals upon the seismic risk evaluation with an example. By providing a method for determining the effect of a small number of subintervals upon the results of seismic risk quantification, the present study will assist seismic PSA analysts to determine the appropriate number of subintervals and to better understand seismic risk quantification.

Current Status of Interval of Heparin Flushing for Maintenance of an Implanted Port in Solid Tumor Patients (고형암 환자의 삽입형 포트 개방성 유지를 위한 헤파린 관류 주기 현황)

  • Kim, Hye Kyung;Choi, So Eun;Lee, Jung Hoon;We, Eun Sook;Joh, Hye Jin;Kim, Kwang Sung
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.3
    • /
    • pp.251-257
    • /
    • 2014
  • Purpose: Little is known about appropriate interval periods between the heparin flushing of implanted ports after completion of chemotherapy. The purpose of this study was to describe the current status of interval of heparin flushing for maintenance of an implanted port in solid tumor patients. Methods: We performed a retrospective review of all patients who had undergone implanted port removal in 2012 at the Seoul St. Mary's Hospital. The subjects were 90 patients who, after completion of chemotherapy, retained their ports for extended periods of time. Results: The mean number of flushes of heparin was 4. Compliance with visits for implanted port maintenance varied with the individual, and the mean accession times were in the range between 13 days and 243 days. The overall mean time between flushes was 66 days. One patient showed resistance during flushing. Conclusion: Our results demonstrate that extending the flushing interval to a maximum of 8 weeks remains medically safe. Less frequent heparin flushing of an implanted port decreases medical expenditure and the workload of medical professionals; it also improves the patient's satisfaction.

Robotic versus Laparoscopic versus Open Gastrectomy: A Meta-Analysis

  • Marano, Alessandra;Choi, Yoon Young;Hyung, Woo Jin;Kim, Yoo Min;Kim, Jieun;Noh, Sung Hoon
    • Journal of Gastric Cancer
    • /
    • v.13 no.3
    • /
    • pp.136-148
    • /
    • 2013
  • Purpose: To define the role of robotic gastrectomy for the treatment of gastric cancer, the present systematic review with meta-analysis was performed. Materials and Methods: A comprehensive search up to July 2012 was conducted on PubMed, EMBASE, and the Cochrane Library. All eligible studies comparing robotic gastrectomy versus laparoscopic gastrectomy or open gastrectomy were included. Results: Included in our meta-analysis were seven studies of 1,967 patients that compared robotic (n=404) with open (n=718) or laparoscopic (n=845) gastrectomy. In the complete analysis, a shorter hospital stay was noted with robotic gastrectomy than with open gastrectomy (weighted mean difference: -2.92, 95% confidence interval: -4.94 to -0.89, P=0.005). Additionally, there was a significant reduction in intraoperative blood loss with robotic gastrectomy compared with laparoscopic gastrectomy (weighted mean difference: -35.53, 95% confidence interval: -66.98 to -4.09, P=0.03). These advantages were at the price of a significantly prolonged operative time for both robotic gastrectomy versus laparoscopic gastrectomy (weighted mean difference: 63.70, 95% confidence interval: 44.22 to 83.17, P<0.00001) and robotic gastrectomy versus open gastrectomy (weighted mean difference: 95.83, 95% confidence interval: 54.48 to 137.18, P<0.00001). Analysis of the number of lymph nodes retrieved and overall complication rates revealed that these outcomes did not differ significantly between the groups. Conclusions: Robotic gastrectomy for gastric cancer reduces intraoperative blood loss and the postoperative hospital length of stay compared with laparoscopic gastrectomy and open gastrectomy at a cost of a longer operating time. Robotic gastrectomy also provides an oncologically adequate lymphadenectomy. Additional high-quality prospective studies are recommended to better evaluate both short and long-term outcomes.