• Title/Summary/Keyword: interval load

검색결과 282건 처리시간 0.029초

Association between Dietary Acid Load and Insulin Resistance: Tehran Lipid and Glucose Study

  • Moghadam, Sajjad Khalili;Bahadoran, Zahra;Mirmiran, Parvin;Tohidi, Maryam;Azizi, Fereidoun
    • Preventive Nutrition and Food Science
    • /
    • 제21권2호
    • /
    • pp.104-109
    • /
    • 2016
  • In the current study, we investigated the longitudinal association between dietary acid load and the risk of insulin resistance (IR) in the Tehranian adult population. This longitudinal study was conducted on 925 participants, aged 22~80 years old, in the framework of the third (2006~2008) and fourth (2009~2011) phases of the Tehran Lipid and Glucose Study. At baseline, the dietary intake of subjects was assessed using a validated semi-quantitative food frequency questionnaire, and the potential renal acid load (PRAL) and net endogenous acid production (NEAP) scores were calculated at baseline. Fasting serum insulin and glucose were measured at baseline and again after a 3-year of follow-up; IR was defined according to optimal cut-off values. Multiple logistic regression models were used to estimate the risk of IR according to the PRAL and NEAP quartile categories. Mean age and body mass index of the participants were 40.3 years old of $26.4kg/m^2$, respectively. Mean PRAL and NEAP scores were -11.2 and 35.6 mEq/d, respectively. After adjustment for potential confounders, compared to the lowest quartile of PRAL and NEAP, the highest quartile was accompanied with increased risk of IR [odds ratio (OR)=2.81, 95% confidence interval (CI)=1.32~5.97 and OR=2.18, 95% CI=1.03~4.61, respectively]. Our findings suggest that higher acidic dietary acid-base load, defined by higher PRAL and NEAP scores, may be a risk factor for the development of IR and related metabolic disorders.

최적화 모델을 이용한 경제적인 총량관리 할당기법 연구 (The Allocation Methods for Economical Efficiency Using an Optimized Model)

  • 최인욱;신동석;김홍태;박재홍;안기홍;김용석
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

전력계통에 있어서 신에너지전원(연료전지)의 최적 운용방안에 관한 연구 (A Study on the Optimal Operation of Fuel Cell in Power Systems)

  • 노대석;홍승만;이은미
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2002년도 추계학술발표논문집
    • /
    • pp.141-144
    • /
    • 2002
  • Recently, the operation of power distribution systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome these problems, a study on the planning and operation in distribution systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems has been performed energetically. This study presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell systems, in the case of both only electric power supply and thermal supply as well as electric power supply. In other words, the optimal operation of these sources can be determined easily by the principle of equal incremental fuel cost and the thermal merits is evaluated quantitatively through Kuhn-Tucker's optimal conditions. In order to select the optimal locations of those sources, an priority method using the comparison of total cost at the peak load time interval is also presented. The validity of the proposed algorithms is demonstrated using a model system.

A Parallel Hybrid Soft Switching Converter with Low Circulating Current Losses and a Low Current Ripple

  • Lin, Bor-Ren;Chen, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1429-1437
    • /
    • 2015
  • A new parallel hybrid soft switching converter with low circulating current losses during the freewheeling state and a low output current ripple is presented in this paper. Two circuit modules are connected in parallel using the interleaved pulse-width modulation scheme to provide more power to the output load and to reduce the output current ripple. Each circuit module includes a three-level converter and a half-bridge converter sharing the same lagging-leg switches. A resonant capacitor is adopted on the primary side of the three-level converter to reduce the circulating current to zero in the freewheeling state. Thus, the high circulating current loss in conventional three-level converters is alleviated. A half-bridge converter is adopted to extend the ZVS range. Therefore, the lagging-leg switches can be turned on under zero voltage switching from light load to full load conditions. The secondary windings of the two converters are connected in series so that the rectified voltage is positive instead of zero during the freewheeling interval. Hence, the output inductance of the three-level converter can be reduced. The circuit configuration, operation principles and circuit characteristics are presented in detail. Experiments based on a 1920W prototype are provided to verify the effectiveness of the proposed converter.

작업유형에 따른 생리학적 작업능력의 비교 분석 (Comparison analysis of physiological work capacity for different tasks)

  • 박지수;김홍기;최진영
    • 대한인간공학회지
    • /
    • 제15권2호
    • /
    • pp.89-98
    • /
    • 1996
  • The objective of this study was to make comparison of the physical work capacities with different types and methods of tasks. To produce standard work loads, a bicycle ergometer and a treadmill were used for the purpose of two different types of tasks. Maximal oxygen uptake measurement tests are usually performen (1) continuously - with no rest between work load increments, or (2) discontinuously - with the subjects resting several minutes between work periods. Continuous test protocol with two different methods of work load increments, (1) ramp test- with 3 to 5 minutes of work period for each work load, and (2) incremental test - where exercise intensity was increased progressively in 2 minutes interval, were used. Predicted physicala work capacities (PWCs) were compared with the one by Kim(1990), and Lee(1995), and the NIOSH physiological criteria. For ergometer test, the PWC based on the ramp test was 89.65% of the one based on the incremental test. The PWC values were 2553.88 ml/min for the ramp test and 2848.82 ml/min for the incremental test. For treadmill test, the PWC based on the ramp test was 97.54% of the one based on the incremental test. The PWC values were 2786.89 ml/min for the ramp test and 2857.24 ml/min for the incremental test. The PWC obtained with a bicycle ergometer was 91.64% of the one obtained with a treadmill for the ramp test, and 99.71% for the incremental test.

  • PDF

전력계통에 있어서 분산형 연료전지 발전시스템의 최적 도입계획에 관한 연구 (A Study on the Optimal Planning for Dispersed Fuel Cell Generation Systems in Power Systems)

  • 노대석;심헌;오용택;최재석;차준민
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.265-274
    • /
    • 2001
  • Recently, the operation of power systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome those problems, a study on the planning and operation in power systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems, has been performed energetically. This paper presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell generation systems, considering thermal supply as well as electric power supply. In other words, the optimal operation of those sources can be determined easily by the principle of equal incremental fuel cost and the thermal merit of those sources can be also evaluated quantitatively through Kuhn-Tucker's optimal conditions. In additions, an priority method using the comparison of total cost at the peak load time interval is presented in order ot select the optimal locations of those sources. The validity of the proposed algorithms is demonstrated using a model system.

  • PDF

소음이 과제수행에 미치는 영향에 관한 연구 (The Study on Affecting Subject Accomplishment by Noise)

  • 김성철;박근상;김관우
    • 대한인간공학회지
    • /
    • 제29권1호
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to confirm the impact of noise on subject accomplishment as well as physical/mental load, and evaluates the effects of noise-masking and earplug. 15 college students participate in the test, and the comparison is performed by executing four projects according to conditional categories of noise environments; control condition, noise condition, earplug condition, and noise-masking condition. Noise in the field site of the H manufacturer was used as the noise source, the general job aptitude test which consist of linguistic ability, math ability, perception ability, reasoning ability was used as the task of this project. To estimate physical/mental load evaluation, we used the heart rate R-R interval, Criteria flicker fusion frequency(CFF) and measured NASA-TLX workload for subjective evaluation. As the research outcome, it is shown that there is a meaningful difference for the project task score, dropping rate of CFF, the heart rate, and NASA-TLX subjective evaluation score according to conditions of noise environment. Therefore, the impact of noise on capability of subject accomplishment as well as physical/mental load was confirmed along with the effects of using earplug and noise-masking.

수요측 단기 전력소비패턴 예측을 위한 평균 및 시계열 분석방법 연구 (A Study on Forecasting Method for a Short-Term Demand Forecasting of Customer's Electric Demand)

  • 고종민;양일권;송재주
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.1-6
    • /
    • 2009
  • The traditional demand prediction was based on the technique wherein electric power corporations made monthly or seasonal estimation of electric power consumption for each area and subscription type for the next one or two years to consider both seasonally generated and local consumed amounts. Note, however, that techniques such as pricing, power generation plan, or sales strategy establishment were used by corporations without considering the production, comparison, and analysis techniques of the predicted consumption to enable efficient power consumption on the actual demand side. In this paper, to calculate the predicted value of electric power consumption on a short-term basis (15 minutes) according to the amount of electric power actually consumed for 15 minutes on the demand side, we performed comparison and analysis by applying a 15-minute interval prediction technique to the average and that to the time series analysis to show how they were made and what we obtained from the simulations.

동계 시각별 외기온의 변동 특성에 관한 연구 (Variation Characteristics of Hourly Atmospheric Temperature Throughout a Winter)

  • 이승언;손장열
    • 태양에너지
    • /
    • 제12권2호
    • /
    • pp.1-8
    • /
    • 1992
  • 본 연구는 동계 외기온 데이타의 시각별 변동특성을 파악하기 위하여 연변동 성분 및 기간변동 성분을 제거한 일변동 성분의 매 시각별 외기온 데이타에 대해서 일교차의 발생요인에 대해서 분석하였다. 또한 동계시각별 외기온의 주파수 특성에 대해서 검토하였으며 외기온 데이타의 수식화의 가능성을 제시하였다.

  • PDF

Analysis and Implementation of a New ZVS DC Converter for Medium Power Application

  • Lin, Bor-Ren;Shiau, Tung-Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1296-1308
    • /
    • 2014
  • This paper presents a new zero voltage switching (ZVS) converter for medium power and high input voltage applications. Three three-level pulse-width modulation (PWM) circuits with the same power switches are adopted to clamp the voltage stress of MOSFETs at $V_{in}/2$ and to achieve load current sharing. Thus, the current stresses and power ratings of transformers and power semiconductors at the secondary side are reduced. The resonant inductance and resonant capacitance are resonant at the transition interval such that active switches are turned on at ZVS within a wide range of input voltage and load condition. The series-connected transformers are adopted in each three-level circuit. Each transformer can work as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer. Thus, no output inductor is needed at the secondary side. Three center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Compared with the conventional parallel three-level converters, the proposed converter has less switch counts. Finally, experiments based on a 1.44kW prototype are provided to verify the operation principle of proposed converter.