• 제목/요약/키워드: interrupted

검색결과 705건 처리시간 0.027초

자동 심장충격기 실습 교육 방법에 따른 수행 능력 비교 (Comparison of the skill performance based on an automated external defibrillator training method: A manikin-based study)

  • 임준녕;탁양주
    • 한국응급구조학회지
    • /
    • 제26권1호
    • /
    • pp.7-19
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the interrupted chest compression time during the use of an automated external defibrillator (AED) depending on different AED practice training methods, and to report differences in self-efficacy before and after training. Methods: We enrolled university freshmen who have had cardiopulmonary resuscitation (CPR) training but have not or have had AED training but over 6 months. We examined differences between the group that practiced only shockable rhythms during training and the group that practiced both shockable and non-shockable rhythms. Results: A total of 72 individuals participated in this study, with 36 individuals each in the control and experimental groups. There was no statistically significant difference in the proficiency of AED usage between the two groups. In non-shockable cases, the experimental group showed shorter chest compression interruption time than the control group (2.30±1.21sec vs. 3.16±1.73 sec; p<0.01). In terms of self-efficacy before and after training, both groups showed higher self-efficacy after than before training. Conclusion: Individuals who underwent training that provided practice on both shockable and non-shockable rhythms had a shorter interrupted chest compression time when using the AED.

국도 단속류 구간에서 DSRC를 활용하여 수집한 개별차량 통행시간의 최적 수집 간격 결정 연구 (Determination of the Optimal Aggregation Interval Size of Individual Vehicle Travel Times Collected by DSRC in Interrupted Traffic Flow Section of National Highway)

  • 박현석;김영찬
    • 대한교통학회지
    • /
    • 제35권1호
    • /
    • pp.63-78
    • /
    • 2017
  • 연구는 국도 단속류 구간에서 DSRC로 수집한 개별차량 통행시간의 대푯값 산정 시 신뢰도를 높이는 최적 수집 간격을 결정하는데 목적이 있다. 이를 위하여, 단속류 구간에서 수집되는 가장 대표적인 개별차량 통행시간의 분포인 양봉형태의 비대칭 분포를 따르는 수집데이터를 활용하고 개별차량 통행시간의 수집 간격 크기를 변화시켜 MSE(Mean Square Error)를 추정함으로 오차가 최소가 되는 최적 수집 간격 크기를 결정한다. MSE 산정을 위한 편의 추정식은 비대칭 분포에서도 활용이 가능한 t-분포의 최대 추정 오차식을 활용하였다. 최적 수집 간격 분석을 위한 데이터 수집 간격은 단속류 구간에서 신호정지로 데이터 수집이 정상적으로 결측 되는 1-2분 수집 간격은 제외하고, 3분 이상의 수집 간격만을 대상으로 하였다. 데이터 수집 시 결측을 발생시키는 수집 간격은 결측 데이터 보정처리 과정에서 또 다른 오차를 유발하게 되어 배제하였다. 분석결과 MSE가 최소가 되는 최적 수집 간격은 3-5분이며, 통행시간 증가 시 최적 수집 간격은 3분으로 짧아짐을 확인하였다. 시스템 운영의 효율성과 통행시간 대푯값 산정의 신뢰도 향상을 모두 고려할 때 기본 수집 간격은 기존과 같이 5분으로 운영하고, 정체 시는 3분으로 수집 간격을 줄여 운영하는 것이 효과적일 것으로 사료된다.

미시적 접근법에 의한 평균 공급지장비용단가 산정 방법론 연구-II (A Study on Methodology of Average Interrupted Energy Assessment Rate using Micro Approach-II)

  • 오태곤;임진택;최재석;전동훈;이병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.357-358
    • /
    • 2011
  • A major element in the evaluation of reliability worth is the customer cost associated with a loss of supply. This paper proposes a new methodology to estimate the IEAR(Interrupted energy assessment rate) based on expectation value of outage time by using micro approach. The case study in this paper was performed on the basis of the survey data which had been conducted in a previous research.

  • PDF

심실중격결손증, 개방성 대동맥관 및 개방성난원공과 동반한 대동맥궁 결손증: 1례보고 (Interrupted Aortic Arch [Type A] associated with ventricular septal defect, patent ductus arteriosus and patent foramen ovale)

  • 김한용
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.206-211
    • /
    • 1991
  • Interruption of the aortic arch may be defined as discontinuity of the aortic arch in which either an aortic vessel or a patent ductus arteriosus supplies the descending aorta. This anomaly is a rare congenital malformation that usually occurs with severe associated intracardiac congenital anomalies, such as ventricular septal defect, patent foramen ovale and abnormal arrangement of the brachiocephalic arteries. Rarely, transposition of the great vessel, truncus arteriosus are coexistent. We experienced a case of the interrupted aortic arch [Type A] associated with VSD, PDA and patent foramen ovale in a 16 years old female. One stage total correction was done under profound hypothermia with total circulatory arrest. Aortic continuity was established using patent ductus arteriosus with anterior wall of main pulmonary artery, which was anastomosed obliquely to anteromedial side of the ascending aorta. Ventricular septal defect was closed using Dacron patch and patent foramen ovale was closed directly. Postoperative course was uneventful, except mild hoarseness.

  • PDF

배전자동화 계통의 루프 운전시 보호협조에 관한 연구 (A Study on the Protective Coordination of Distribution Automation System under Loop Operation)

  • 이희태;문종필;김재철
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1281-1286
    • /
    • 2009
  • As a general radial configuration of power distribution system, the various researches have being studied to change a radial configuration to network one such as smart, intelligent and micro grid for loop operation. If a radial configuration changes to network, protective coordination comes to the biggest problem. When a typical protective algorithm is applied to loop distribution system protection, the interrupted section is expanded, therefore, reliability grows worse. This paper presents the new protective method being able to apply to loop distribution system with Distribution Automation System (DAS) which separate the minimal faulted section. Through contingency analysis of the sustained and momentary fault, we analyzed the influence for radial configuration and loop configuration using interrupted area and proved the effectiveness of proposed method.

상온압축시험에서 측정응력과 유동응력과의 관계고찰 (Review on Measured Stress and Flow Stress at Room-Temperature Compression Test)

  • 박종수;이영선;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.13-15
    • /
    • 2001
  • Compression test has been used to measure material flow stress due to limited capability of tensile test at the fast strain rate. Since the frictional stress unavoidable during compression test should be properly eliminated from the measured stress, calibration of the measured stress by using friction factor has been made for the flow stress measurement. Also, calibrated stresses by interrupted and continuous compression tests have been compared with the true stress measured by tensile test at $0.2\%$ carbon steel.

  • PDF

대동맥궁 결손증의 완전교정 치험 1예 (Interrupted Aortic Arch(Type A) associated with PDA, VSD, Mitral Regurgitation and Single Coronary Artery)

  • 이재진
    • Journal of Chest Surgery
    • /
    • 제21권3호
    • /
    • pp.588-593
    • /
    • 1988
  • We experienced a case of interrupted aortic arch[Type A] associated with PDA, VSD, mitral regurgitation and single coronary artery. The patient was 7 years old boy, who showed congestive heart failure[NYHA functional class III]. One stage total correction was performed under profound hypothermia with total circulatory arrest. Aortic continuity was established using PDA with anterior wall of main pulmonary artery flap. VSD was closed with Dacron patch and mitral regurgitation repaired by Reed`s annuloplasty method. The postoperative cardiac catheterization revealed no pressure gradient between ascending aorta and descending aorta, decreased pulmonary artery pressure and trivial residual shunt[Qp/Qs: 1.28]. The aortogram showed good continuity of the aorta without narrowing of the anastomotic site. During the period of 1 year follow up, heart failure symptoms were nearly subsided.

  • PDF

급성상기도감염 항생제 처방률 공개 효과 분석 (The Effect of Public Report on Antibiotics Prescribing Rate)

  • 김수경;김희은;백미숙;이숙향
    • 한국임상약학회지
    • /
    • 제20권3호
    • /
    • pp.242-247
    • /
    • 2010
  • Controlling inappropriate antibiotics prescribing for acute upper respiratory infections(URI) is a very important for prudent use of antibiotics and resistance control. Health Insurance Review and Assessment Service (HIRA) introduced Prescribing Evaluation Program and publicly reported antibiotics prescribing rate for URI of each health institution. We performed segmented regression analysis of interrupted time series to estimate the effect of public report on antibiotics prescribing rate using national health insurance claims data. The results indicate that just before the public report period, clinics' monthly antibiotics prescribing rate for URI was 66.7%. Right after the public report, the estimated antibiotics prescribing rate dropped abruptly by 12.3%p. There was no significant changes in month-to-month trend in the prescribing rate before and after the intervention.

간척지에서 수도 및 기타작물의 내염성에 관한 연구 2. 여러 가지 염분조건에서 배추와 양배추의 내염성에 관하여 (Study on the Salt Tolerance of Rice and Other Crops in Reclaimed 2. On the Salt Tolerance of Chinese Cabbage and Cabbage in Various Salty Conditions)

  • 임형빈
    • Journal of Plant Biology
    • /
    • 제12권3호
    • /
    • pp.8-14
    • /
    • 1969
  • Salt tolerances of Chinese cabbage and cabbage were observed by means of the sand culture and field experiment. The point of 50% yield reduction of Chinese Cabbage was 1% of salt concentration in sand culture. The Na absorption in the salty upland conditions was increased but the absorption of Ca, Mg were interrupted as the salt concentration was raised and there were no differences in the absorption of N and P. The Si absorption was increased at low salty conditions, but the salt concentration was raised, the absorption was interrupted drastically. The cabbage was more stronger salt tolerance than Chinese cabbage, and it was possible to prevent the salt damage significantly by planting on sloping beds instead of planting on the double-row beds in field condition.

  • PDF